Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 29, 2016 FBO #5424
AWARD

Z -- B23NH HVAC Repairs

Notice Date
9/27/2016
 
Notice Type
Award Notice
 
NAICS
541330 — Engineering Services
 
Contracting Office
N40085 NAVFAC Mid-Atlantic, ROICC Newport Naval Activities Building #1 Newport, RI
 
ZIP Code
00000
 
Solicitation Number
N4008516R4637
 
Response Due
7/25/2016
 
Archive Date
10/27/2016
 
Point of Contact
Alexander Olarte
 
E-Mail Address
alexander.olarte@navy.mil
(alexander.olarte@navy.mil)
 
Small Business Set-Aside
Total Small Business
 
Award Number
N40085-14-D-5250-0015
 
Award Date
9/27/2016
 
Awardee
UPSTATE CONSTRUCTION SER VIC ES, INC<br />
 
Award Amount
$1,403,964.00
 
Line Number
0001
 
Description
DESCRIPTION OF WORK Existing HVAC system in the Central Sterilization Room and adjacent Decontamination Room is to be revised to better control temperature, humidity, and pressurization by removing them from the main HVAC system and providing their own AHU. Existing AHU-4/5 are to be replaced. AHU-4 is located within the attic space of the exterior ambulance port/canopy. AHU-5 is located within a second floor Mechanical Room. Existing baseboard radiators throughout B23 require replacement (approximately 1,000 LF). Two existing ceiling-mounted split DX units in Laboratory are to be replaced with in-kind units. 2.B. SCOPE OF WORK: In addition, the following items are included in scope as bid options and are numbered as such in the contract documents: 1. Bid Option #1: Existing isolation valves serving chilled/heating water systems as well as domestic hot/cold water systems are to be replaced. 2. Bid Option #2: Existing supply/return fan motors on AHU-1/2/3 within the Penthouse of B23 are to be replaced. 3. Bid Option #3: Three existing precast decorative concrete fascia panels around the base of the cooling tower have shifted and require restoration to their original location. The contractor will be limited to work on Sundays or overnight and be required to move furniture and equipment as well as ensure the work area is returned to service the next morning. The contractor will be allowed to shut down the Central Sterilization Room and Decontamination Room for four continuous days after scheduling the shutdown with the building users. A Dust Control and Infection Control Program will also be required of the contractor. (Drawing and door schedule are attached for reference).
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62472NP/N4008516R4637/listing.html)
 
Record
SN04289389-W 20160929/160927235118-f63f2024239f8a5f3ad7c4a3966923e8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.