Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 04, 2016 FBO #5399
DOCUMENT

N -- Install New Security System - Attachment

Notice Date
9/2/2016
 
Notice Type
Attachment
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 4;Pittsburgh Pa, 15215
 
ZIP Code
15215
 
Solicitation Number
VA24416Q1462
 
Archive Date
10/2/2016
 
Point of Contact
John Barton
 
E-Mail Address
johnny.barton@va.gov
(johnny.barton@va.gov)
 
Small Business Set-Aside
N/A
 
Description
The Philadelphia Veteran Affairs Medical Center intends to negotiate on a sole source basis with Tri-State Security and Controls LLC 4142 Ogletown Stanton Road 232 Newark, DE 19713 to install, program and commission a new Security System at the Burlington Community Base Outpatient Clinic in Marlton, NJ 08053 (See list below) in accordance with FAR 6.302-1. The VA is leasing the Burlington CBOC property from 3000 Lincoln, LLC and Tri-State Security & Control is 3000 Lincoln, LLC only approved vendor for this effort. TSC had previously installed the network cabling for the Burlington CBOC and is familiar with the property. This Notice of Intent is NOT a request for competitive proposals. Parties may identify their interest; accompanied by supporting literature, to the Contracting Officer no later than September 7, 2016 at 1:00 p.m. EST. ALL Responses should be sent to johnny.barton@va.gov. No telephone responses will be accepted. Information received will be for the purpose of determining whether or not to conduct a competitive procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer. The NAICS Code for this procurement is 238210. Contracting Office Address: Attn: John Barton, Department of Veterans Affairs Network Contracting Office 4, 1010 Delafield Road Pittsburgh, Pennsylvania 15215-1802 Security Package Description: Access Control Panel, Door Hardware, and System Programming including all accessories: 1 PRO-64RUP - 64 Access Readers Upgrade for All PRO Systems; No Maximum on Number of Readers 1 LNL-2220 - Intelligent Dual Reader Controller - 12 VDC or 24 VDC @ 700mA, size (6" (152mm) W x 8" (203mm) L x 1" (25mm)H), (5 year lithium battery or 3 months full run) 6 MB standard cardholder flash memory, 50,000 of Event memory, maximum of 32 devices, On-board Ethernet, on-board two door control, eight inputs, four outputs, cabinet tamper and power fault input monitors. RoHS, CE, C-Tick and UL 294 2 LNL-1320 - Dual Reader Interface Module (Series 2 - Supports OSDP Readers) - 12/24 VDC, 2 Reader interface, W/M, 8 inputs, 6 (5A) form C relays, RoHS, CE, C-Tick and UL294 certified 1 LNL-CTX-6 - Lenel UL Listed Hardware Enclosure (24" x 18" x 4.5"), only with lock and tamper switch. (UL Approved) (can house up to 6 boards) 5 920PHRNEK00004 - RDR, RP40-H, PIVCLASS, SE E, LF STD, HF STD/SIO/SEOS/FIPS/CAK, 485FDX, PIG, BLK, STD-1, LED RED, FLSH GRN, BZR ON, FIPS 200-BIT, IPM OFF, UART OFF, WIEG ON 5 EEB2-G EMERY EXIT BTN SNGL GANG 30SEC 5 M680BDX - M680BDX MAG W REX 5 2707A-L High Security Contacts w/Armored Cable, Triple Biased, SPDT, 3/16" to 5/8" Gap Size. Single Pole-Double Throw. 3' Stainless Steel Armored Cable 5 DS160 PIR REQUEST TO EXIT SENSOR WITH SOUNDER GRAY 1 FPO150/150-C8D8 E2 - 8 lock, 8 aux outputs 12A/12V or 6A/24V (150W) and 12A/12V or 6A/24V (150W) fused at 3A E2 enclosure 4 PS12750U - 12V 75 AMP ACC Nut & Bolt Auto-Cn 2 BB-55F - BATTERY BACK BOX RED 2.0 FIELD LABOR/SYSTEM COMMISSIONING 1 Submissions - Submissions & Reproduction 1 Electronic Documents - Preparation of Electronic Documents 1 Engineering Application Design Services 1 CAD - Drawings CAD Services - Drawings 1 Project Management - Project Management Labor 1 Tech Services 1 - System Start up and Check Out 1 Programming - System Programming 1 Staff Training - Employee (6 Staff) one day training of Nexus Client Software Installation and EMS Configuration and Operation of the System. Training to take place during normal business hours (7:30 AM to 4:00 PM). The system software and associated system components must be FIPS201 compliant. The PACS shall be administered and monitored by the VA Police at the CMCVAMC Philadelphia location. The system shall allow for the programming of the controller at the Burlington CBOC site, from the CMCVAMC Philadelphia server. This shall be performed remotely with a fully functional network connection from the CMCVAMC Philadelphia location to the Burlington CBOC site. This site would essentially be an extension of the CMCVAMC Philadelphia (1675) PACS. Reader licenses shall be included as part of this project. The network infrastructure to support a VPN/VLAN connection from the Burlington CBOC site to the PACS server at the CMCVAMC Philadelphia location is by others. It is the intent create a dedicated network connection between the Burlington CBOC and the PACS server at the CMCVAMC Philadelphia location. The contractor is required to program and commission the system. Networked HD IP Surveillance and Panic Button Systems including all accessories: 1 Airship HSNG 2400 12JJ - HP Airship Hybrid NVR System, Up To 24 Camera Licenses, 12 TB Storage 1 Cisco SF200-48P - Cisco SF200-48P Smart Switch: 48 10/100 Ports, PoE, 2 Combo Mini-GBIC Ports 1 ICC ICCMSCMA52 - Panel, Cable Management Interbay, 2 RMS 1 ICC ICMPP0245E - ICC's CAT 5e Patch Panel 24-Port 1RMS 1 Panamax MB1500 - 1500VA, 900 Watt, Battery Backup for Critical Devices and Surveillance Continuity 7 SnapAV PATCH-CAT6-2FT-BLU - Wirepath Cat 6 2ft Ethernet Patch Cable (Blue | 3 Pack) 1 TSC VMS and Camera Programming Labor - Professional VMS Programming, Camera Configuration by Integration Programmer 20 HIKVISION DS-2CD4132FWD-IZ - 3 Megapixel WDR Indoor Dome Network Camera 1 TSC Camera Installation Labor - Camera Installation Includes Trim-Out, Testing, Patching, Focusing, and Mounting of All Interior Cameras by a Professional Integration Technician 1 TSC Rough-in Installation Labor - Wiring of Category Cabling, Mounting Associated J Hooks and Prep Cable for Trim-Out 2 Honeywell Security 5881ENHC Commercial Wireless Receiver 2 TSC Installation and Panic Button Programming Labor Installation and Programming of Panic Button System and Tie-in with Existing Security Panel, Including Wireless Button Enrollment (Includes Security Cable) 32 Honeywell Ademco 5802WXT One-button Wireless Personal Panic Transmitter Contractor to provide and install a full IP networked surveillance system as approved by the CMCVAMC Police to match CMCVAMC standards. (20) Cameras shall be 3 Megapixel with Varifocal Len's, dome network cameras. The backend shall be punched down in the IT rack according to TIA/EIA-568A standards. The VMS shall be an embedded unit as provided by Airship VMS and custom designed to match CMCVAMC standards. Installation shall include all cabling, mounting associated J hooks and prep cable for trim-out.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/VA24416Q1462/listing.html)
 
Document(s)
Attachment
 
File Name: VA244-16-Q-1462 VA244-16-Q-1462_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2986922&FileName=VA244-16-Q-1462-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2986922&FileName=VA244-16-Q-1462-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04253373-W 20160904/160902234504-7ba80d2a906cf9b61dbf9f8023e908e4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.