DOCUMENT
66 -- Benchtop, medium-priced flow cytometer for molecular biology - Attachment
- Notice Date
- 8/23/2016
- Notice Type
- Attachment
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- US Department of Veterans Affairs;Veterans Health Administration;Service Area Office (SAO) East;323 North Shore Drive, Suite 500;Pittsburgh PA 15212-5319
- ZIP Code
- 15212-5319
- Solicitation Number
- VA24016Q0073
- Response Due
- 8/26/2016
- Archive Date
- 9/2/2016
- Point of Contact
- Lynn Portman
- Small Business Set-Aside
- N/A
- Description
- The Department of Veterans Affairs, Atlanta VA Medical Center, has a requirement to purchase a benchtop, medium-priced flow cytometer for molecular biology/immunology for research purposes. The purpose of this synopsis is to gain knowledge of potential qualified sources who can meet the salient characteristics below and their size classification (large business, small business, 8(a), SDVOSB, etc.), relative to NAICS code 334516. Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. Based on responses to this synopsis, the Government may issue this RFQ as a Brand Name or Equal requirement in accordance must include the following specifications: Salient Characteristic: "System must be able to process samples at sample flow rates between 10 µl and 240 µl per minute while providing high sensitivity and adjustable flow rates. "System must be able to provide 7 decades of resolution, 24 Bit; 16,777,216 channels resolution and an event collection rate of (30,000 events/sec). "System must be able to calibrate sample volume delivery to perform absolute cell counts without a requirement to use expensive bead products. "System must be able to provides simultaneous measurement of up to 5 fluorescent channels from the (488nm) Blue laser excitation, 3 fluorescent channels from the (638nm) Red laser, and five fluorescent channels from the (405nm) Violet laser. "System must be equipped with software that allow visualization of data acquisition and data analysis modules and includes a license to CytExpert software at no cost that is designed to collect and analyze flow cytometry data. "System must be equipped with featured analysis software featuring time saving functions such as "linear gain" and automatically modify compensation following gain setting changes and "auto threshold" function. "System must allow software automatically set the threshold based on population scaling in order to easily find target population. "Equipped with 3 lasers with 6 detectors. "Small foot print to fit comfortably in the limited laboratory space (23"x 40"x 20"). "Detect the cell surface molecules but also the intracellular or nuclear events simultaneously. "Compatibility with this specific software (FlowJo) is essential. "Computer loaded with software. "Specific configuration can be modified without the need of manufacturer's staff dispatch. "Allows analyses of extracellular staining of proteins. "Allows intracellular protein staining as well as DNA staining. "Fully equipped with internal software and the workstation. "Optical units integrated into the flow cell. "Software with no limitation on a number of downloads "Preloaded with all the upgradeable modules. "15 parameters on a single sample, up to 13 color fluorescence data channels, plus forward and side scatter. "Process samples at sample flow rates between 10 ?L and 240 ?L per minute providing high sensitivity and adjustable flow "Calibrated sample volume delivery to perform absolute cell counts 7 decades of resolution, 24 Bit; 16,777,216 channels resolution and an event collection rate of (30,000 events/sec) "Rates, sample sizes as low as 10 ?L and a high degree of flexibility in the types of analysis that can be performed. "<30 MESF?FITC, <10 MESF PE. "Full configuration (5/3/5) provides simultaneous measurement of up to 5 fluorescent channels from the (488nm) Blue laser excitation, 3 fluorescent channels from the (638nm) Red laser, and five fluorescent channels from the (405nm) Violet laser. "All the lasers and detectors come equipped with the machine. "Consumables, one each of reagents starter kit. "Detection module with solid?state, high efficiency, low?noise detectors for a flexible detection system that allows which also minimizes light loss with efficient transmission of emitted light. "Versacomp antibody capture beads. Delivery Information: Atlanta VA Medical Center Attn: Juanita Grant 404.321.6111 ext. 6688 1670 Clairmont Road Decatur, Georgia 30033 Performance Period: Anticipated delivery within 90 calendar days of award, unless otherwise specified at time of order. T ype of Contract: Firm Fixed Price This notice is not a request for competitive proposals, however; any responsible source who believes it is capable of meeting the requirement may submit a capability statement to the contracting office no later than Tuesday, August 16, 2016, 11:00 AM, EST. Interest/capability statements may be sent to Lynn Portman at lynn.portman@va.gov and should include company name, address, point of contact, business size, and product information. No telephone responses will be accepted. This notice is to assist the Government in determining sources only. A solicitation is not currently available. If a solicitation is issued, all interested parties must respond to that solicitation announcement separately from the responses to this announcement.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/8c63d423f9a70bdbf60e955bd3cb8798)
- Document(s)
- Attachment
- File Name: VA240-16-Q-0073 VA240-16-Q-0073.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2960256&FileName=VA240-16-Q-0073-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2960256&FileName=VA240-16-Q-0073-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA240-16-Q-0073 VA240-16-Q-0073.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2960256&FileName=VA240-16-Q-0073-000.docx)
- Place of Performance
- Address: Atlanta VA Medical Center;1670 Clairmont Road;Decatur, Georgia 30033
- Zip Code: 30033
- Zip Code: 30033
- Record
- SN04237818-W 20160825/160824000327-8c63d423f9a70bdbf60e955bd3cb8798 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |