Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 21, 2016 FBO #5354
SOLICITATION NOTICE

Z -- DISA building 200, Upgrade Fire Suppression

Notice Date
7/19/2016
 
Notice Type
Presolicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Fort Worth, Attn: CESWF-CT, PO Box 17300, Fort Worth, Texas, 76102-0300, United States
 
ZIP Code
76102-0300
 
Solicitation Number
W9126G-16-R-0101
 
Archive Date
9/17/2016
 
Point of Contact
Craig D. Harper, Phone: 8178861239, Marc H. Nguyen, Phone: 8178861028
 
E-Mail Address
craig.d.harper@usace.army.mil, marc.h.nguyen@usace.army.mil
(craig.d.harper@usace.army.mil, marc.h.nguyen@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
The resultant of this project will provide DISA with fully functional upgraded fire detection and suppression systems (complete with project timelines, Specifications, Design Calculations, Drawings, O&M Manuals, and Training) in Computer Rooms 1, 2A and 2B. Demolition shall include removal of existing wet-pipe fire sprinkler system segments not compatible or convertible back to a pre-action system in Computer Rooms 1, 2A and 2B. Design and installation shall consist of the installation of new Clean Agent and nitrogen filled double interlock fire sprinkler suppression systems in computer rooms 1, 2A and 2B meeting current applicable local building codes, standards and regulations as well as DoD and DISA standards. Design and installation shall also address exhausting in identified areas at a rate of one (1) cfm per square foot of floor space. The original building computer room and data storage area in the central portion of the facility were protected with Halon fire suppression systems. After enactment of the Clean Air Act in 1994 and the adoption of a non-use policy by the DoD, the Halon systems were replaced with a conventional wet pipe sprinkler systems. With the development of clean agent chemical compounds that meet the guidelines outlined in the Clean Air Act and also present very low exposure risk to equipment and humans, clean agent fire protection is to be reintroduced into the critical computer and communication equipment areas. The project objective is to design and construct a Clean Agent Fire Protection Systems and Pre-Action Automatic Sprinkler Systems for Building 200, Port San Antonio, San Antonio, TX. The three computer rooms contain servers which shall be maintained in operation throughout the contract. Room CR2A contains one small desk and chair with minimal (half-hour) daily usage, Room CR2B contains a work cubicle for two personnel which manned 0700-1600 M-F. The remaining rooms CR1 and CR3 are solely server rooms. Contractor shall be responsible for moving cubicle/desk/chairs as required and coordinate computer/electronics relocation with Defense Enterprise Computing Centers (DECC) through the Contractor Officer Representative (COR).
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA63/W9126G-16-R-0101/listing.html)
 
Place of Performance
Address: Defense Information Systems Agency, San Antonio, Texas, 78226, United States
Zip Code: 78226
 
Record
SN04187842-W 20160721/160719234811-eecbf623463ad19235cc50c9a231343e (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.