SOLICITATION NOTICE
J -- PRESERVATION MAINTENANCE FOR THE CGC MACKINAW
- Notice Date
- 3/31/2016
- Notice Type
- Presolicitation
- NAICS
- 336611
— Ship Building and Repairing
- Contracting Office
- Department of Homeland Security, United States Coast Guard (USCG), USCG Surface Forces Logistics Center (SFLC) Procurement Branch 1, 300 East Main Street, Suite 600, Norfolk, Virginia, 23510-9102, United States
- ZIP Code
- 23510-9102
- Solicitation Number
- HSCG85-16-Q-P30A78
- Point of Contact
- Sandra A Martinez, Phone: (757) 628-4591
- E-Mail Address
-
Sandra.A.Martinez@uscg.mil
(Sandra.A.Martinez@uscg.mil)
- Small Business Set-Aside
- HUBZone
- Description
- PRE-SOLICITATION NOTICE: PRESERVATION MAINTENANCE FOR USCGC MACKINAW. The United States Coast Guard; Surface Forces Logistics Center (SFLC) Norfolk, VA is procuring preservation maintenance services for the U. S. Coast Guard Cutter USCGC MACKINAW. This is a Hub Zone Set-Aside. The applicable North American Industry Classification System (NAICS) code is 336611 for SHIP BUILDING AND REPAIRING with a Size Standard of 1,250 employees. For the calculation of annual receipts and number of employees see parts 121.104 and 121.106 in SBA's Small Business Size Regulations. The RFQ/Solicitation will be issued pursuant to FAR 12, Acquisition of Commercial Items and FAR Part 13.5, SIMPLIFIED PROCEDURES FOR CERTAIN COMMERCIAL ITEMS. The simplified acquisition will be issued as a Best Value, Request for Quote (RFQ), on or about April 11, 2016. The solicitation will be issued electronically on the FEDBIZOPPS web page at http://www.fedbizopps.gov. It is incumbent upon contractors to monitor the FEDBIZOPS web page for RFQ release and all subsequent amendments. Please sign up for the Auto Notification service to receive e-mail from FEDBIZOPPS when an action is taken under this solicitation. If you have questions regarding FEDBIZOPPS, contact Sandra Martinez at (757) 628-4591 or email sandra.a.martinez@uscg.mil. Hard copies of the specification and solicitation will not be issued. REQUIREMENT: This notice is issued by the U.S. Coast Guard, Surface Force Logistics Center, Norfolk, VA to identify sources capable of providing Preservation Maintenance Services for the USCGC MACKINAW (WLBB 30). The contractor(s) performing any preservation work involving "critical-coated" surfaces must be either SSPC-QP 1 certified or obtain the services of an Independent QP-1 and NACE -Certified inspector requirement. The vessel is home ported in Cheboygan, MI. All work will be performed at the home pier. Contractor shall provide all necessary materials, equipment, and personnel to provide preservation maintenance services to the USCGC MACKINAW (WLBB 30). The vessel is home ported in Cheboygan, MI. Work shall be performed at the vessel's homeport. SCOPE OF WORK: The scope of the acquisition is preservation maintenance services for the USCGC MACKINAW. This work will include, but is not limited to the following work items: Weather Deck Surfaces - Level 1 (100 sqft, Continuous to 500 sqft, Continuous ) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 (100 sqft, Continuous to500 sqft, Continuous ) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 05 Level, Frames 45 - 65 (Approx 1,426 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 05 Level, Frames 62 - 65 (Approx 60 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 04 Level Port, Frames 53 - 95 (Approx 830 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 04 Level Stbd, Frames 53 - 99 (Approx 890 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 04 Level CNTR, Frames 80 - 95 (Approx 250 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 02 Level, Frames 95 - 106 (Approx 282 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 01 Level Fantail, Frames 109 - 133 (Approx 1,900 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 01 Level Port, Frames 46 - 83 (Approx 340 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 01 Level Stbd, Frames 46 - 83 (Approx 340 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 01 Level Port, Frames 83 - 109 (Approx 830 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 01 Level Stbd, Frames 83 - 109 (Approx 870 sqft) - Critical-Coated Surfaces Weather Deck Surfaces - Level 2 - 01 Level Focs'le, Frames J - 13 (Approx 1,370 sqft) - Critical-Coated Surfaces Bouy Deck Surface - Level 2 - Main Level, Frames 09 - 46 (Approx 3,133 sqft) - Critical Coated Surfaces Bouy Deck Surface - Level 1 (100 sqft, Continuous to 500 sqft, Continuous) - Critical Coated Surfaces Hull Plating (Buoy Port Areas), Preserve Freeboard Surfaces Preserve - "Partial" - Level 1 (100 sqft, Continuous) - Critical-Coated Surfaces Freeboard Surfaces Preserve - "Partial" - Level 1 (500 sqft, Continuous) - Critical-Coated Surfaces Freeboard Surfaces Preserve "100%" - Level 2 (100 sqft, Continuous to 500 sqft, Continuous) - Critical-Coated Surfaces Main Mast Surfaces - Level 2 (100 sqft, Continuous to500 sqft, Continuous) Main Mast Surfaces - Level 1 (100 sqft, Continuous to 500 sqft, Continuous) Superstructure Surfaces Preserve, 100% - Level 2 (100 sqft, Continuous to 500 sqft, Continuous ) - Critical-Coated Surfaces Superstructure Surfaces Preserve "Partial"- Level 1 (100 sqft, Continuous to 500 sqft, Continuous) - Critical-Coated Surfaces Stack Surfaces (Exterior), Preserve - "100%" - Level 2 (100 sqft, Continuous) Miscellaneous Ship Structures, Preserve Deck Fitting (Bouy & Non-Bouy Deck) - Level 1 Miscellaneous Ship Structures, Preserve Deck Fitting (Bouy & Non-Bouy Deck) - Level 2 Miscellaneous Ship Structures, Preserve Machinery, Exterior - Level 1 (10 sqft, Continuous to 100 sqft, Continuous) Miscellaneous Ship Structures, Preserve Machinery, Exterior - Level 2 (10 sqft, Continuous, to100 sqft, Continuous ) Miscellaneous Ship Structures, Preserve Machinery, Interior - Level 1 (10 sqft, Continuous to 100 sqft, Continuous) Miscellaneous Ship Structures, Preserve Machinery, Interior - Level 2 (10 sqft, Continuous to 100 sqft, Continuous) Miscellaneous Ship Structures, Preserve Railing and Stanchion - Level 2 (10 lnft, continuous) Miscellaneous Ship Structures, Preserve Railing and Stanchion - Level 1 (10 lnft, continuous) Miscellaneous Ship Structures, HANDRAILS & STANCHIONS, 100 LINEAR FEET CONTINUOUS LEVEL I, 500 LINEAR FEET CONTINUOUS Miscellaneous Ship Structures, HANDRAILS & STANCHIONS, 100 LINEAR FEET CONTINUOUS LEVEL II, 500 LINEAR FEET CONTINUOUS Miscellaneous Ship Structures, Preserve Bulkhead and Overhead Surfaces (Un-insulated), and Door - Level 2 (100 sqft, Continuous and(500 sqft, Continuous) Miscellaneous Ship Structures, Preserve Bulkhead and Overhead Surfaces (Un-insulated), and Door - Level 1 (100 sqft, Continuous)and (500 sqft, Continuous) Miscellaneous Ship Structures, Preserve Bulkhead and Overhead Surfaces (Un-insulated), in Wet Spaces - Level 1 (100 sqft, Continuous) and (500 sqft, Continuous) Miscellaneous Ship Structures, Preserve Bulkhead and Overhead Surfaces (Un-insulated), in Wet Spaces - Level 2 (100 sqft, Continuous) and- Level 2 (500 sqft, Continuous) Miscellaneous Ship Structures, Preserve Interior Deck Surfaces - Level 1 (100 sqft, Continuous to 500 sqft, Continuous) Miscellaneous Ship Structures, Preserve Interior Deck Surfaces - Level 2 (100 sqft, Continuous to 500 sqft, Continuous) Miscellaneous Ship Structures, PREP OF SPAR COATED COLOR SURFACES ( DEGLOSS AREA/100 GRIT &DEGLOSS TOPCOAT LEVEL #1 (10 SQUARE FEET), (50 SQUARE FEET), (100 SQUARE FEET) Miscellaneous Ship Structures, LEVEL #2 PREP OF SPAR COLOR COATED SURFACES (DEGLOSS AREA/60GRT PAPER/DEGLOSSER PROVIDE MID COAT & TOPCOAT) Miscellaneous Ship Structures, PREP OF SPAR COLOR COATED SURFACES (DEGLOSS AREA/60GRT PAPER/DEGLOSSER PROVIDE MID COAT & TOPCOAT), LEVEL #2 (10 SQUARE FEET) Miscellaneous Ship Structures, PREP OF SPAR COLOR COATED SURFACES ( DEGLOSS AREA/60GRT PAPER/DEGLOSSER PROVIDE MID COAT & TOPCOAT), LEVEL #2 (100 SQUARE FEET) Miscellaneous Ship Structures, PREP OF SPAR COLOR COATED SURFACES ( DEGLOSS AREA/60GRT PAPER/DEGLOSSER PROVIDE MID COAT & TOPCOAT), LEVEL #2 (50 SQUARE FEET) Machinery Space Bilges - Level 1 (100 sqft, Continuous)and (500 sqft, Continuous) Tenting, Provide - Level 1 (100 Square Feet)and (500 Square Feet) Anticipated Period of Performance: This acquisition shall be a requirements contract for One Base year and Four Option Years; if exercised. Orders for preservation maintenance shall be placed by delivery order when needed. Anticipated start date on or about 15 August 2016 through 16 August 2017 (Base Year). (Subject to change at the discretion of the Government). NAICS Code/Size Standard: The applicable NAICS Code is 336611, Ship Building and Repairing and the size standard is 1,250 employees. This solicitation is Subject to Availability of Funds. All responsible sources may submit an offer, which shall be considered by the United States Coast Guard. For information concerning this acquisition contact the Contracting Official listed above
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/COUSCGMLCA/HSCG85-16-Q-P30A78/listing.html)
- Place of Performance
- Address: 627 COAST GUARD DRIVE, CHEBOYGAN, Michigan, 49721, United States
- Zip Code: 49721
- Zip Code: 49721
- Record
- SN04068407-W 20160402/160331234628-8a2845cb068f29875ef04c67d273dcb1 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |