Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 27, 2016 FBO #5238
SOURCES SOUGHT

Z -- 285 Ton Chiller Installation at the GT Leland Federal Building - Sources Sought-Attachment A

Notice Date
3/25/2016
 
Notice Type
Sources Sought
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
General Services Administration, Public Buildings Service (PBS), Acquisition Management (7PQA), 819 Taylor St., Rm. 12B01, Fort Worth, Texas, 76102, United States
 
ZIP Code
76102
 
Solicitation Number
GS-07-P-16-LELAND
 
Archive Date
4/19/2016
 
Point of Contact
Shawna M. Villarreal, Phone: 8178505541
 
E-Mail Address
shawna.villarreal@gsa.gov
(shawna.villarreal@gsa.gov)
 
Small Business Set-Aside
N/A
 
Description
Sources Sought-Attachment A Project Description The General Services Administration, Public Building Service, Region 7, is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to provide and install one 285 ton nominal capacity magnetic bearing chiller (two or more compressors) and condenser water and chilled water pump with variable frequency drives. The Place of Performance is at the GT Leland Federal Building located at 1919 Smith St, Houston, TX. All necessary connections, valves, pumps, piping and electrical modifications shall be included. In addition, the new chiller's control system shall communicate with the existing building automated system. Replacement Chillers shall be wired to and communicate by BACNet directly to the Building's Niagara JACE Controller. The Chillers shall not be linked through a propriety building system controller. Contractor will be responsible to verify the existing BAS and provide all necessary wiring, controls, and/or Modbus/BACNet cards (if needed) to integrate chiller's controls to BAS. The Contractor will have 30 days to complete the work after the chiller arrives on site. The new chiller requirements are as follows: 285 tons of cooling Evaporator EWT/LWT (F) 54.0/44.0 Evaporator GPM - 679.8 Condenser EWT/LWT (F) 86/96 Condenser GPM - 810.4 Evaporator Pressure Drop (Not to exceed) - 5 psi Condenser Pressure Drop (Not to exceed) - 6 psi Minimum two compressor chiller The applicable North American Industry Classification System (NAICS) code to be assigned to this procurement is 238220; the associated small business size standard is 15 million. The magnitude of construction is between $250,000 and $500,000. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals. Submission of any information in response to this market survey is purely voluntary. The government assumes no financial responsibility for any costs incurred associated to this request for capability information. If your organization has the potential capacity to perform these contract services, please provide the following information: (1) A complete and current record of your registration within the System for Award Management, located at https://www.sam.gov/. The record shall include your DUNS number, organization name, address, contact name, email address, web site address, telephone number, type of organization, and small business type(s). (2) A capability statement supporting claims of organizational and staff capability to perform the tasks listed in the "Project Description" paragraph above. (3) In order to demonstrate successful experience as a General Construction (GC) Contractor and/or as Plumbing, Heating, and Air Conditioning contractor, please provide at least three but no more than five similar chiller removal and installation projects (200 Ton or larger) substantially completed within the past five years from the issuance of this Sources Sought utilizing Attachment A. Please complete the document in its entirety. GSA requests that potential sources only submit the minimum information necessary. The result of this market research will contribute to determining the method of procurement, including type of small business set-aside. NO LARGE businesses need to respond to this notice. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. However, GSA may contact sources to gather additional information as required. Submission Instructions: Interested parties, excluding large businesses, who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 2:00 PM (CDT), Monday, April 4, 2016. All responses under this Sources Sought Notice must be emailed to Shawna Villarreal, Contracting Officer, at the following address: shawna.villarreal@gsa.gov
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/7PMA/GS-07-P-16-LELAND/listing.html)
 
Place of Performance
Address: GT Leland Federal Building, 1919 Smith St, Houston, Texas, United States
 
Record
SN04063402-W 20160327/160325234713-58a79c7c00afebc9b9f996453cf63359 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.