SOURCES SOUGHT
66 -- SP0600-16-RFI-1007 Laboratory Equiptment for Alaska and Korea
- Notice Date
- 3/17/2016
- Notice Type
- Sources Sought
- NAICS
- 333249
— Other Industrial Machinery Manufacturing
- Contracting Office
- Defense Logistics Agency, DLA Acquisition Locations, DLA Energy, 8725 John J. Kingman Road, Fort Belvoir, Virginia, 22060-6222, United States
- ZIP Code
- 22060-6222
- Solicitation Number
- SP0600-16-RFI-1007
- Point of Contact
- Zulma L. Irizarry, Phone: 7037678210, DLA Energy PEC, Fax: 703-767-8506
- E-Mail Address
-
zulma.irizarry@dla.mil, DLAEnergyPEC@dla.mil
(zulma.irizarry@dla.mil, DLAEnergyPEC@dla.mil)
- Small Business Set-Aside
- N/A
- Description
- Defense Logistics Agency (DLA) Energy is issuing this sources sought notice as a means of conducting market research to identify parties having an interest in and the resources to support for the below listed laboratory equipment. The result of this sources sought notice will contribute to the determination of the method of procurement will be executed. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 333249. THERE IS NO SOLICITATION AT THIS TIME. This Sources Sought notice does not constitute a request for quote, bid or proposal; submission of any information in response to this sources sought notice is purely voluntary; the government assumes no financial responsibility for any costs incurred and shall retain all information provided with no expectation of return. If your organization has the capability to perform these requirements, please provide the following information: •1) Organization name, address, email address, Web site address, telephone number, cage code and size and type of ownership for the organization. •2) To determine commerciality; please provide a small exert as to whom this product was sold too. Please exclude all U.S. Government agencies •3) All below listed products will be "Brand Name or Equal"; is there any restrictive information listed that would make using "Brand Name or Equal" unfair? [ Note: If your company is interested in possible opportunities with DLA Energy, we recommend verifying your SAM registration.] Requirements: CLIN 0001 Nomenclature: Existent Gum Bath, Jet Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D381, Gum Content in Fuels by Jet Evaporation. Must have 6 sample positions or stations - no more, no less. Should be constructed of a machined aluminum block with multiple cartridge heaters. Must have a pressure regulator and an air flowmeter built-in as a single unit. Must be 220-240V, 50/60Hz, Single Phase, and not more than 15A. Dimensions must less than 29"Lx21"Wx17"D to accommodate available space. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Koehler Instruments, Model: K33700 Existent Gum Evaporation Bath CLIN 0002 Nomenclature: High Frequency Rotating Rig (HFRR), Diesel Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D975, Standard Specification for Diesel Fuel Oils. The HFRR is called out specifically by the ASTM D975 specification. It should include the HFRR testing unit, a humidity controlled cabinet, metallurgical microscope, pc printer, wear scar camera with software and calibration kit, computer with appropriate connection cables, standard HFR specimen pack, and a HFRR screw set. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG: Compass-Instruments; Model: HFRR for Diesel Fuel. CLIN 0003 Nomenclature: Ellipsometer, Jet Fuel Unit of Issue: EA Quantity: 0002 Description: Shall adhere to ASTM D3241, Thermal Oxidation Stability of Aviation Turbine Fuels (JFTOT Procedure) for heater tube rating procedure. Must rate the heater tube as pass/fail as well as measure deposits - deposit thickness ranging 0 to 500 nm, deposit volume ranging 0 to 0.5 mm3. Must be 110/115V. Dimensions must less than 12w x 20d to accommodate available space. Height is unrestricted. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Alcor, Model: OptiReader CLIN 0004 Nomenclature: Microseparomter, Automated, Jet Fuel Unit of Issue: EA Quantity: 0002 Description: Shall adhere to ASTM D3948, Determining Water Separation Characteristics of Aviation Turbine Fuels by Portable Separometer. Must be available in 115V +/- 10v. Should be portable and contain a rechargeable battery. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Emcee, Model: 1140 Micro-Separometer CLIN 0005 Nomenclature: Bath, Copper Strip Corrosion, Jet and Diesel Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D130, Corrosiveness to Copper from Petroleum Products by Copper Strip Test. Bath should have digital, temperature controller and some form of circulation of bath media. Must have 8 openings to run 8 individual samples, a Soxhlet reflux condenser, and constant water level viewing tube. Bath must be capable of reaching a minimum of 100C. Must be available in 115V 60Hz, Single Phase, and no more than 8A. Required dimensions not more than 18 "Lx 13"W. Height is not restricted Bath's liquid media must be water or water/antifreeze mixture. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Koehler Instruments, Model: K25320 ASTM D130 Copper Strip Corrosion Test Bomb Bath CLIN 0006 Nomenclature: COLORIMETER, Automated, Jet Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D156, Saybolt Color of Petroleum Products and D6045, Color of Petroleum Products by the Automatic Tristimulus Method. Must be available in 115V. Required dimensions not more than 22 "W x 10"D and weigh less than 20lbs. Height is not restricted. Interface should have USB, LAN, RS232 and be programed for remote calibration and maintenance via the internet. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG LOVIBOND, Model: PFX195 i /2 Saybolt Color of Jet Fuel CLIN 0007 Nomenclature: Centrifuge, Tabletop, Diesel Fuels Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D2709, Water and Sediment in Middle Distillate Fuels by Centrifuge. Should be a 4 position, tabletop centrifuge. Should contain 4 trunnions, 4 individually heated D model cups, include a built-in tachometer, a hand brake, and designed for Class 1, Group D, Division 2. Height is not restricted however; the unit must fit a 28" x 28" space. Should weigh less than 160 lbs. Must be 115V +/- 10v. Accessories to be included are 100ml Long Cone Tubes(PK of 6), marked in milliliters every 1ml above 10ml. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Milton Lab Model Centrifuge or Benchmark 2000 Lab Model Centrifuge CLIN 0008 Nomenclature: Jet Fuel Thermal Oxidation Tester, Jet Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D3241, Thermal Oxidation Stability of Aviation Turbine Fuels (JFTOT Procedure). The Tester should be parts compatible with our current JFTOT III manufactured by Alcor to maximize parts interchangeability and calibration needs. It should be the most current generation model, the JFTOT IV. Should be so automated as to significantly reduce operator interface over previous generations by at least 50%. Must be over 18" X 25". Height is not restricted. Weight must be no more than 140 pound. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Alcor: Model: JFTOT IV, Jet Fuel Thermal Oxidation Tester CLIN 0009 Nomenclature: Flash Point Testing Unit, Automatic, Jet Fuel and Diesel Unit of Issue: EA Quantity: 0002 Description: Shall adhere to ASTM D93 Flash Point by Pensky-Martens Closed Cup Method capable of flash point measurements from 30C to 400C and must be compatible with the PS400 Temperature Probe and the Meriam Manometer for calibration. Must use an Electric Igniter with built-in Fire Extinguisher. Power needs are 115V +/- 10V, 50/60 Hz and no more than 1200W. Size must be less than 11"wide x 21"deep. Height is not restricted. Must include Safety Alarm System that detects, as a minimum, automatic detection of method or safety violations and a Safety Pre-dip. A built-in barometric pressure sensor for automatic correction of flash point. An automatic stirrer capable of 0 to 300 RPMs. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Hertzog: Model: OptiFlash Pensky-Martens Standard Model Gas Igniter BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION, and multiple awards MAY be made. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Submission Instructions: Interested partiesare invited to submit a response to this Sources Sought Notice by March 31,2016 at 13:00 Fort Belvoir Virginia time. All responses under this Sources Sought Notice must be emailed to Zulma.irizarry@dla.mil AND DLAEnergyPEC@dla.mil.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DLA/J3/DESC/SP0600-16-RFI-1007/listing.html)
- Place of Performance
- Address: Alaska and Korea, Alaska, United States
- Record
- SN04054469-W 20160319/160317235556-6f1e6e313c8f8e508765d8ead6c3634a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |