Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 25, 2016 FBO #5207
SOLICITATION NOTICE

66 -- Cryogenc Cooling System - Synopsis Solicitation

Notice Date
2/23/2016
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B130, Gaithersburg, Maryland, 20899-1410, United States
 
ZIP Code
20899-1410
 
Solicitation Number
NB686010-16-01133
 
Archive Date
3/18/2016
 
Point of Contact
Marc R. Zurasky, Phone: 3034973246
 
E-Mail Address
marc.zurasky@nist.gov
(marc.zurasky@nist.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
Specifications Combined Synopsis Solicitation TECHNICAL SPECIFICATIONS Each unit must meet the following technical specifications: 1. Cold stage base temperature less than 1K or colder 2. Run time: at least 24 hours or greater continuously with 100 microwatt thermal load at 1K or colder 3. Cycle time (<1K to 4 K back to <1K): less than 90 minutes 4. Fully compatible with our existing air-cooled, Gifford-McMahon cryocooler (Sumitomo model #SRDK-101D), which can reach a base temperature of 3 K and has a cooling power of 100 mW at 4.2K 5. RuO2 thermometer fitted to the base plate 6. Diode thermometry to pumps and switches supplied by vendor 7. All wiring carried to an MDM micro-D connector, or equivalent, mounted on unit 8. The entire unit must be less than 9" tall, less than 2.5" deep and no more than 4.5" wide. 9. The 1K pot cannot be larger than 2" in diameter 10. Mounting area of the cooler / footprint for attaching the cooler to the plate that is cooled by the second stage of the mechanical cooler must be less than 3 square-inches. 11. The system (or similar units) must have a demonstrated record of being used to cool devices below 1K. 12. The manufacturer must have sold similar units and have a track record of good after-market customer support, e.g., repairs and spare parts. References/past customers must be available upon request. TECHNICAL CONSIDERATIONS The compact, closed-cycle cryogenic cooling systems must fit into our existing cryocoolers inside the 5" diameter 4K can. Therefore, there are stringent requirements on the dimensions of these units. The entire unit must be less than 9" tall, less than 2.5" deep and no more than 4.5" in wide. In addition, the 1K pot cannot be larger than 2" in diameter. The mounting area for attaching the cooler needs to be minimal (less than 3 square-inches) to accommodate wiring and optical fibers in our small existing cryostat design.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/NB686010-16-01133/listing.html)
 
Place of Performance
Address: 325 S. Broadway, Boulder, Colorado, 80305, United States
Zip Code: 80305
 
Record
SN04028834-W 20160225/160223235956-a2fbf0188af9a322d6679633d517101b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.