SOLICITATION NOTICE
Z -- DEA Lab Upgrade - Drawings - Request For Proposals
- Notice Date
- 2/10/2016
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- General Services Administration, Public Buildings Service (PBS), Acquisition Management Division, Customer Projects Team (5P1QCD), General Services Administration, Public Buildings Service, 230 S. Dearborn Street, Rm 3300, Chicago, Illinois, 60604, United States
- ZIP Code
- 60604
- Solicitation Number
- GS-05-P-16-FB-C-7002
- Archive Date
- 3/25/2016
- Point of Contact
- Jennifer E. Styzek, Phone: 3123531214, Neal Deodhar, Phone: 3123853051
- E-Mail Address
-
jennifer.styzek@gsa.gov, neal.deodhar@gsa.gov
(jennifer.styzek@gsa.gov, neal.deodhar@gsa.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- The project involves the extensive renovation of a DEA laboratory facility located at 536 South Clark Street in Chicago, IL. The project consists of the following: 1. Provide new temperature controls. 2. Replacing exhaust and supply air flow sensors in all labs. 3. All new control valves, damper actuators, temperature and pressure sensor for all 6 AHUs. 4. Replace all supply and exhaust VAV boxes including actuators and controls. 5. Re-balancing of room air flows and all coil water flows. 6. Remove all Pneumatic controls and pneumatic air system. 7. Replace the 6 existing Air handling units (AHUs) with new AHUs. 8. Replace in-duct fire alarm devices at the AHU's. 9. Modify sprinkler piping in fan rooms to adapt to new fan and duct configurations. 10. Replace 6 lab exhaust fans on roof with 2 new coil to coil heat recovery exhaust systems. 11. Rebalance the supply and exhaust air systems to establish 10 air changes per hour in the lab spaces and a pressure differential of -0.05" in the laboratory to keep the laboratory negative relative to the corridor. 12. Provide two new hot water preheat coil systems including dual pumps and converters and all controls. 13. Provide two new glycol heat recovery coil systems including dual pumps and converters and all controls. 14. Replace all zone perimeter hot water heating control valves. 15. Replace and/or relocate certain supply air diffusers to improve air distribution and reduce drafts. 16. Reprogram the BAS and add equipment to generate outgoing message to contact building maintenance.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/5PCT/GS-05-P-16-FB-C-7002/listing.html)
- Place of Performance
- Address: Federal Building, 536 S. Clark Street, Chicago, Illinois, 60605, United States
- Zip Code: 60605
- Zip Code: 60605
- Record
- SN04017309-W 20160212/160210235430-eb3c038fbf6d735a6b668497dcc3a0d5 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |