SOLICITATION NOTICE
Z -- Replace and Improve Roof Cover and Rainwater Drainage Systems
- Notice Date
- 1/20/2016
- Notice Type
- Presolicitation
- NAICS
- 238160
— Roofing Contractors
- Contracting Office
- General Services Administration, Public Buildings Service (PBS), Acquisition Management Division (4PQ), 77 Forsyth Street, Suite T8, Atlanta, Georgia, 30303, United States
- ZIP Code
- 30303
- Solicitation Number
- GS-04P-15-EX-C-0186
- Point of Contact
- William T. Peterson, Jr., Phone: 704-926-7071
- E-Mail Address
-
william.peterson@gsa.gov
(william.peterson@gsa.gov)
- Small Business Set-Aside
- N/A
- Description
- THIS IS A FULL AND OPEN SOLICITATION, NO RESTRICTION This project will be awarded to the contractor that submits the lowest priced, technically acceptable (LPTA) offer. Replace and Improve Roof Cover and Rainwater Drainage Systems, The Historic U.S. Courthouse, 100 Otis Street, Asheville, North Carolina 28801-2611 The project involves the design, repair, replacement, and improvement of roof cover systems and rainwater drainage systems at the Historic U.S. Courthouse, Asheville, North Carolina. The existing low-slope roof cover involves twelve separate roof areas totaling approximately 13,000 square feet. The low-slope roof cover consists of ballasted single-ply EPDM membrane over lightweight weight insulating (cinder) concrete and structural concrete decks. However, the sally port roof involves rigid board insulation and metal decking, in addition to the EPDM membrane. The steep slope roof cover involves approximately 15,000 square feet of standing seam metal roof membranes over the attic and approximately 1,500 square feet of contiguous gutters. Both roof cover systems include EPDM base flashing; metal counterflashing; concrete parapet copings; internal rain leaders and conductors; and associated sealants. The Designer-Builder shall design and construct appropriate repairs, replacements, and improvements of these roof cover and rainwater drainage systems. New low-slope roof membranes are limited to multi-layer atactic polyproylene (APP) or styrene butadiene styrene (SBS) modified bitumen roofing systems with highly reflective surfaces. New gutter membranes are limited to fluid-applied aliphatic polyurethane and polymethylmethacrylate (PMMA) waterproofing. Section 4 of this statement of work provides additional requirements for these new systems and components. The Design-Builder shall also provide a web-camera surveillance system to monitor on-site work progress through project completion. In addition, the designer-builder shall provide a twenty-year (20-year), no-dollar-limit (NDL) warranty on all areas of low-slope roof replacements, and a ten-year (10-year) NDL warranty on the gutter waterproofing system. The warranties shall include wind riders to cover damage caused by winds speeds up to one-hundred forty (140) miles per hour or to the design wind speed for the building location, whichever is less. The estimated price range is between $1,000,000.00 and $5,000,000.00. The Design-Build (DB) Contractor is to provide a proposed project schedule. The following criteria will be used to evaluate whether or not a contractor is technically acceptable for this project: 1. Provide documentation from customers on at least three (3) separate roof replacement projects and at least three (3) separate cured-in-place-pipe (CIPP) projects indicating their satisfaction with the work of the proposed installers and their willingness to work with the installers in the future. Each roof project must involve installation of at least 15,000 square feet of low-slope roof cover with torch-applied multi-layer modified bitumen roof membranes. Each CIPP project must involve installation of at least 500 linear feet of cured in place pipe. 2. Provide certification(s) from the proposed roof cover manufacturer and from the proposed CIPP manufacturer that the installers are trained and qualified to install their torch-applied modified bitumen roof membranes, reinforced fluid-applied flashing/waterproofing systems, and CIPP systems. The certifications must be dated no earlier than January 1, 2015. 3. Provide copies of manufacturer’s warranties issued within the past three years for at least three (3) roof replacement projects. Each project must involve installation of at least 15,000 square feet of low-slope roof cover with torch-applied modified bitumen roof membranes. The warranties must cover both labor and material defects for a period of at least 20 years. 4. Provide a copy of the CIPP manufacturer’s proposed warranty. At minimum, the manufacturer’s warranty must cover material defects for 50 years and workmanship defects for 5 years. 5. Provide documentation that the proposed CIPP manufacturer has at least 5 years of experience in manufacturing and/or supplying air inversion or pull in place liner tube materials approved by NSF, IAPMO, and ICC-PMG using a quality assurance/quality control program meeting or exceeding the requirements of ISO 9000. GSA anticipates issuing a solicitation for this project no later than Friday, February 12, 2016. The anticipated proposal due date will be Friday, March 11, 2016. Oral communications, telecommunications, and faxed inquiries or comments are NOT acceptable as a response to this Notice. Only e-mail responses will be accepted. Please Note: A prospective Offeror that is interested in obtaining a contract award with the Government must be registered in the Federal Government's System for Award Management (SAM) database, formally the Central Contractor Registration (CCR), prior to contract award. Information regarding contractor registration can be obtained through the following website: www.sam.gov
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/4PCA/GS-04P-15-EX-C-0186/listing.html)
- Place of Performance
- Address: The Historic U.S. Courthouse, 100 Otis Street, Asheville, North Carolina, 28801-2611, United States
- Zip Code: 28801-2611
- Zip Code: 28801-2611
- Record
- SN03996032-W 20160122/160120234342-1790a88c2c92af1b59770bfa18b17a45 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)