Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 06, 2016 FBO #5157
SOLICITATION NOTICE

66 -- TEST EQUIPMENT - SOLICITATION

Notice Date
1/4/2016
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Tulsa, Attn: CESWT- CT, 1645 South 101st East Avenue, Tulsa, Oklahoma, 74128-4609, United States
 
ZIP Code
74128-4609
 
Solicitation Number
W912BV-16-T-0014
 
Archive Date
5/31/2016
 
Point of Contact
ROBERT NORRIS, Phone: 9186697279
 
E-Mail Address
Robert.L.Norris@usace.army.mil
(Robert.L.Norris@usace.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
TEST EQUIPMENT STATEMENT OF WORK The following equipment is required to perform commissioning activities in accordance with NEBB section 4 ‘Standards for Equipment, Instrumentation and Calibration'. Without these items it will not be possible to properly test and commission the air moving equipment, water moving equipment, verify air barriers, test plumbing systems, or troubleshoot the mechanical systems as required by the contract. Without properly commissioning the systems and buildings, the Government will not be able to verify the Owner's Project Requirements and ensure contract compliance. Attachments are for comparison of required equipment specifications of brand name or equal submissions only Any alternate submissions other than requested primary equipment must have specifications submitted or proposal will be disqualified due to non-compliance Required - Cx Equipment 1.) 1 Each - AirData Multimeter Electronic Micromanometer - ADM-870C with 200 reading memory; standard density sea level equivalent air flow and velocity readings; automatic reading mode for continuous reading update or memory entry; selective display of associated pressure and temperature for velocity and airflow readings. Standard and optional accessories are listed below. o Add 1 each option WinWedge TM user-friendly software package downloads readings from ADM-860C or ADM-870C into a spreadsheet. Includes software, RS232 serial cable, adapter, customized data organization templates SWE-1 2.) 1 Each - Airflow Capture Hood Kit - Flowhood Kit 8403 with 2'x2', 2'x4', and 1'x4' tops o Add 1 each option Small top set for small exhaust and return air in close quarters (14"x14"x14") 3.) 1 Each - Hydrodata Multimeter Electronic Pressure Gage - HDM-250 Complete kit with valve network panel & hoses 4.) 1 Each Fluke 376 True RMS AC/DC Clamp Meter with iFlex 5.) 1 Each Cooper-Atkins SRH77A-E 1 and 2 Zone Temp/Humidity Thermistor Instrument with 1075 General Purpose Puncture Probe, 4011 Pipe Strap Probe, and 5028 Humidity Probe, - 40 degrees F to 300 degrees F temp range. 6.) 1 Each FLIR E6 Compact Thermal Imaging Camera with 160 X 120 IR Resolution and MSX 7.) 10 Each Lascar EL-USB-2-LCD+ High Accuracy Humidity Temperature and Dew Point Data Logger with LCD. AirData Multimeter ADM-870C ELECTRONIC MICROMANOMETER AIR FLOW VELOCITY PRESSURE TEMPERATURE ADM-870C ELECTRONIC MICROMANOMETER SPECS ADM-870C SPECS MAIN PAGE The ADM-870C AirData Multimeter is designed specifically for applications with very demanding air distribution requirements and features an RS232 Communications Port which allows the user to download readings to a printer or computer. SERIAL OUTPUT TO PRINTER or COMPUTER LABORATORY ACCURACY MASS FLOW EQUIVALENT or TRUE AIR FLOW and VELOCITY MEMORY and AVERAGING ENGLISH and METRIC UNITS VELGRID and AIRFOIL SUPPLY and EXHAUST FUME HOODS Air quality control maintenance for hospitals, pharmaceutical, biological and medical research laboratories, semiconductor manufacturing clean rooms, and other applications in which the highest standards of the industry must be met. UTILIZING SOFTWARE from TAL Technologies, Inc. www.taltech.com. SUPPLEMENTARY DOCUMENTS INSTRUCTIONS Get a quick start - using the WINWEDGE TM configuration files RS232 Download using HyperTerminal - Windows XP and earlier MAINTENANCE It is suggested that the AirData Multimeter be returned to the factory at least every two years for recalibration, maintenance, and software update. Following this suggestion will keep the meter up to date with upgrades and new features. Recalibration every two years will also assure that the original accuracy of the meter is maintained throughout the life of the meter. ADM-880C | ADM-870C | ADM-860C | ADM-850L | CFM-850L | CFM-88L | HDM-250 | MT-440K Multi-Temp Kit | Capture Hood Kits | VelGrid Shortridge Instruments, Inc. 7855 E. Redfield Rd. Scottsdale, AZ 85260-3430 USA 480-991-6744 fax 480-443-1267 E-MAIL ADDRESSES Information Sales Technical Questions ©1999-2015 Shortridge Instruments, Inc. All Rights Reserved. copyright policy www.shortridge.com ADM-870C PRODUCT SPECIFICATIONS AirData Multimeter ADM-870C ELECTRONIC MICROMANOMETER SPECS ADM-880C ADM-870C ADM-860C ADM-850L CFM-88L HDM-250 AIR VELOCITY: ±3% of reading ± 7 fpm 50 to 8,000 fpm pitot tube (30,000 fpm FS); 50 to 5,000 fpm AirFoil; 50 to 2500 fpm VelGrid. DIFFERENTIAL PRESSURE: ±2% of reading ± 0.001 in wc from 0.0500 to 50.00 in wc, (0.0001 to 60 in wc FS); 20 psid safe pressure. TEMPERATURE: ±0.5°F accuracy from 32°F to 158°F. AIR FLOW: Accuracy is ±3% of reading ±7 cfm from 100 to 2000 cfm; range is 25 to 2500 supply, 25 to 1500 exhaust with 8400 FlowHood. ABSOLUTE PRESSURE: ±2% of reading ±0.1 in Hg from 14 to 40 in Hg referenced to vacuum. 60 psia maximum safe pressure. AMBIENT RANGE: Full range compensation from 40°F to 140°F. AIR DENSITY CORRECTION: Local or standard (mass flow) air density correction range is 14 to 40 in Hg and 32ºF to 158ºF. POSITION SENSITIVITY: Unaffected by position. MEMORY: 200 readings, sequence labeled, sum, average, minimum and maximum. CALIBRATION: Calibration certified NIST traceable. READOUT: 10 digit, 0.4", high contrast, liquid crystal display. METER HOUSING: High impact, molded, "T" grade ABS. METER WEIGHT: 38 ounces (1.08kg), including batteries SIZE: 6.0" x 6.4" x 2.7" (15.2 x 16.3 x 6.9 cm) CONNECTIONS: 1/4" OD slip-on for 3/16" ID soft tubing. BATTERY LIFE: 3000 readings per charge, 500 recharge cycles. The ADM-860C and ADM-870C AirData Multimeters require the following optional accessories for download to a computer: SWE-1 WinWedge TM user-friendly software package downloads readings from ADM-860C or ADM-870C into a spreadsheet. Includes software, RS232 serial cable, adapter, customized data organization templates. CB-SERIAL1 Serial cable for download to computer and printer (RS232, DB9) AIRDATA TM MULTIMETER MULTIFUNCTION METER KITS Model ADM-870C Shipping Weight 19 lbs (8.6 kg), Dim. 23" x 8" x 18" (59 x 20 x 46 cm) Increased capability multifunction meter kit has all the functions of the ADM-860C. Added features include: 200 reading memory; standard density sea level equivalent air flow and velocity readings; automatic reading mode for continuous reading update or memory entry; selective display of associated pressure and temperature for velocity and airflow readings. Standard and optional accessories are listed belowADM-860C, ADM-870C and ADM-880C kits include the following accessories: AFP18 AirFoil Probe, 18" straight stainless steel probe 160-18 18" Dwyer, Series 160, stainless steel pitot tube ADT442 TemProbe, 4"x1/8" stainless steel; air and water PS8201 Battery charger, 115/60 ADT446 TemProbe, 4"x1/16" stainless steel; air and water IM-870C Instruction Manual (or IM-860C, IM-880C) TRC16 1' to 6' retractile temperature cord MC84 Carrying case, foam fitted TEW19 Temperature extension wand, 19" long VLG84 VelGrid assembly and attachments A-303 Static pressure probes (2) 0258 VelGrid tubing, 8' neoprene twin tube CB-USBADAPT1 RS232 DB9 to USB adapter for computers that lack a DB9 connection FLOWHOOD AIR BALANCE SYSTEM KITS AIR FLOW CAPTURE HOOD KITS These capture hood kits DO NOT include a meter and are designed for use with ADM-850L, ADM-860C, ADM-870C and ADM- 880C AirData Multimeters. The kits include: flow measuring base with sensing manifold; two position flaps and control; pushbutton handle; and carrying case. The nylon cloth and frame sizes are shown for standard kits. Shipping dimensions: 28"x13"x25" (71x33x64cm). CONTACT OUR FACTORY FOR SPECIAL TOP SIZES OR ACCESSORY COMBINATIONS. FLOWHOOD KIT 8403 with 2'x2', 2'x4', and 1'x4' tops. Shipping wt. 32 lbs (14.5 kg). 14x14-T SMALL TOP SET for small exhaust and return air only (14"x14"x14"). Shipping wt. 2 lbs (0.9 kg). Cooper-Atkins SRH77A-E 1 and 2 Zone Temperature/Humidity Thermistor Instrument with 1075 General Purpose Puncture Probe, 4011 Pipe Strap Probe and 5028 Humidity Probe, -40°F to 300°F Temperature Range by Cooper Compare: Offers for this product Offers for this product and similar products Thermistors Temperature / Humidity Thermistor Instrument - Traceable to Standards of NIST Model #: SRH77A-032 The experts choice when temperature and relative humidity measurements are critical since it is a fast and accurate tool. Features Include: LCD backlight for dark environments; sealed keypad which protects the instrument from spills and dust; and a battery eliminator jack. View temperature differential, % relative humidity, and wet-bulb. View temperature differential between zones 1 and 2 and review min/max temperatures from all three zones. The SRH77A-E-032 includes the #1075 general purpose puncture probe, #4011 pipe strap probe and #5028 slim humidity probe. Certificate of Calibration & Report included. Product Specifications Humidity Accuracy ±2% (from 20 to 80% RH), ±3% (below 20% and above 80%) Certifications CE, WEEE, RoHS Auto Shut-off Yes, after 15 minutes of non-use (can be disabled) Humidity Range 10 to 95% RH Warranty 5 year instrument, 1 year probe Modes 3 zone, Min / Max Memory, Wet-bulb, Temperature Differential Temperature Range -40° to 300°F (-40 to 150°C) Temperature Accuracy ±0.3°F (±0.2°C) or ±0.5% reading Resolution 0.1°, 1% RH LCD Height LCD w/backlight (2" x.8") Weight 1lb 5oz ( 595 g) Dimensions 9.5" x 6.5" x 3.5" (241 mm x 165 mm x 89 mm) think FLIR E6: Compact Thermal Imaging Camera with 160 x 120 IR Resolution and MSX FLIR 97 customer reviews Share Style Name:FLIR E6: 160 x 120 Configuration:Standard Imaging and Optical Data IR Resolution 80 × 60 120 × 90 160 × 120 320 × 240 Thermal Image Sample MSX Resolution 320 × 240 Thermal Sensitivity <0.15°C <0.10°C <0.06°C Field of View 45° × 34° Focus Focus Free Detector Uncooled Microbolometer Screen 3.0 in. 320 × 240 color LCD Frame Rate 9 Hz Analysis Image Modes IR image, visual image, MSX, thumbnail gallery IR image, visual image, MSX, picture -in-picture, thumbnail gallery Multi Spectral Dynamic Imaging (MSX) IR image with enhanced detail presentation Picture-in-Picture N/A IR area on visual image Temperature Range -4° F to 482°F (-20° to 250°C) Accuracy ±2% or 2°C Buy Now « Clamp Meters Fluke 373 True RMS AC Clamp Meter Fluke 373 RMS AC Clamp Meter offers improved performance for any AC-only current measurement situations. Find out more about this tool's benefits today. Manuals ☆☆☆☆☆ 3.1 Write a review (7) Specifications AC Current Range 600.0 A Resolution 0.1 A Accuracy 2 % ± 5 digits (48 - 62 Hz) Crest Factor (50/60 Hz) 2.5 @ 600 A AC Voltage Range 600.0 A Resolution 0.1 A Accuracy 1.0 % ± 5 digits (48 - 62 Hz) DC Voltage Range 600.0 A Resolution 0.1 A Accuracy 1 % ± 5 digits Resistance Range 600.0 Ω/6000 Ω Resolution 0.1 Ω/1 Ω Overview Features Reviews Specs Models Accuracy 1 % ± 5 digits Continuity Beeper 30 Ω Capacitance Range 10.0 - 100.0 μF / 1000 μF Resolution 0.1 μF/1 μF Accuracy 1.9 % ± 2 digits Mechanical Specifications Size (L x W x H) 232 mm x 85 mm x 45 mm Weight 370 g Environmental Specifications Operating Temperature -10 °C to +50 °C Storage Temp -40 °C to +60 °C Operating Humidity Non condensing (< 10 °C) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) (Without Condensation) Operating Altitude 3000 meters Storage Altitude 12,000 meters EMI, EMC Meets all applicable requirements in EN61326-1:2006 Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C Safety Compliance ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV Pollution Degree 2 EN/IEC 61010-2-32:2002 EN/IEC 61010-031:2002/A1:2008 Agency Approvals Batteries 2 AA, NEDA 15A, IEC LR6 S HYDRODATA TM MULTIMETER HDM-250 i ELECTRONIC PRESSURE GAGE ● GAGE PRESSURE ● DIFFERENTIAL PRESSURE ● TEMPERATURE ● ● COMPLETE KIT WITH VALVE NETWORK PANEL & HOSES ● PRESSURES DISPLAYED IN PSI, FT HD, IN WC AND IN HG KPA, MHD, MMH2O, & MMHG ● TEMPERATURES DISPLAYED IN F AND C ● AUTO RANGE ● ENGLISH AND METRIC ● BROAD RANGE: 0-250 PSI ● 100 READING MEMORY ● WATER AND AIR THREE READINGS IN ONE The versatile electronic HydroData Multimeter combines the functions and ranges of several gages into a single broad range meter. This meter functions as a compound pressure gage, simultaneously measuring the high side and low side gage pressures along with the differential pressure, and displays each of the readings in sequence. Any reading may be alternately displayed in English or metric units and may be directly converted to other units immediately following display of the reading. Any mix of readings or units can be stored for later recall. EXTREMELY SENSITIVE OVER BROAD RANGE The HydroData Multimeter is accurate across an extremely broad range of fluid gage pressures and differential pressures. The high pressures existing at pumps, chillers, cooling towers, and high rise building conditions can be measured up to 250 psi. The meter will also measure very low pressures, such as reheat coil pressure drops, and low flow conditions on flow measuring orifice plates, or pitot probes down to 0.1 in wc differential and gage pressures. Additional low pressure applications include negative pump suction head and air side pressures of fans, coils and filters. DESIGNED WITH CONVENIENCE IN MIND The HydroData Multimeter comes complete with a shutoff, bypass, and blow down valve network mounted on a portable meter panel. The valve network panel facilitates meter zero procedure, bleed-off of air, venting of pressures, or draining of water. The valves are quarter turn, brass body, stainless steel ball, teflon seat design. The HydroData Multimeter may also be removed from the valve network panel and used independently. The rugged carrying case is designed with storage compartments for accessories, hoses, tools and reports or paperwork. The meter and valve network panel are easily removed from the carrying case and conveniently carried to various project locations. S HYDRODATA TM MULTIMETER HDM-250 i ELECTRONIC PRESSURE GAGE AUTOMATIC RANGE AND MANUAL ZERO This meter automatically selects the proper range and compensates for internal temperature. A combination valve setting and keypad sequence is used to zero the meter, providing unusually accurate low gage and differential pressure readings down to 0.1 in wc. MEMORY STORAGE AND RECALL The memory function of the meter will store up to 100 sets of pressures and/or temperatures with selectively variable units. All readings are tagged and recalled in sequential order. Memory is particularly useful for comparing previous set points to final conditions during the hydronic balancing process. SLOW READING MODE The slow mode averages multiple measurements over a four to eight second sample time to improve repeat- ability and reading accuracy of fluctuating pressures. AUTOMATIC READINGS The auto-read setting allows continuous automatic readings for monitoring ongoing changes in a system as it is being adjusted. This function can be used with the memory mode for later recall and analysis. TEMPERATURE READINGS This meter is ideally suited for temperature efficiency testing of boilers, chillers, cooling towers, coils, and all types of heat transfer and energy recovery systems. The 1/8" or 1/16" diameter, stainless steel TemProbe is uniquely suited for measuring air wet bulb, dry bulb, and water line temperatures. The optional AirData MultiTemp may be used with the HydroData Multimeter to measure temperatures at eight remote locations in very rapid sequence. Kit includes six insertion and two surface probes. THE STANDARD HDM-250 KIT INCLUDES: HydroData Multimeter Model 250 pressure gage. Portable Meter Panel with Valve Network. Compartmented, high impact carrying case. Battery charger: 120 V, 60Hz, 8 W to 24 VAC, 170mA. Two 6' x 1/2" OD reinforced pressure hoses rated for 500 psi working pressure with 1/4" flare ends. Kit also includes two 8' x 1/4" OD polyurethane drain/vent hoses. Set of 1/4" flare adapters and pipe thread fittings from 3/4" through 1/8" MPT and FPT. SPECIFICATIONS DIFFERENTIAL and GAGE PRESSURE - WATER OR AIR: Accuracy is ± 2% of reading ± last digit from 0.1 to 250.0 psi. 400 psi maximum safe pressure. Reads in wc, ft head, in Hg. TEMPERATURE: Measurement range is -67.0° to 250.0° F. Accuracy is ± 0.5° F from 32° to 158° with a resolution of 0.1° F using the ADT 400 Series TemProbes. Safe exposure range for the TemProbe is -100° F to 250° F. AMBIENT RANGE: Full range internal temperature compensation for meter exposure from 40° F to 140° F. MEMORY: 100 sequence labeled, reading sets of pressures and/or temperatures in any selected units. CALIBRATION: Each meter certified, NIST traceable. READOUT: 8 digit, 0.5", high contrast, liquid crystal display. RESPONSE TIME: Two to four seconds standard and up to eight seconds per reading in "SLOW" mode. METER: Dimensions 6.0" x 6.4" x 2.7" high impact ABS. Meter weight 2.2 lbs. Meter and valve panel weight 5.2 lbs. Standard kit shipping weight 21 lbs (9.5 kg); dimensions 19" x 15" x 6" (48 x 38 x 15 cm). CONNECTIONS: Meter; two quick disconnect fittings, 1/8" brass. Valve Network Panel; two 1/4" 45° male flare fittings for pressure hoses. BATTERY LIFE: Up to 20 hours per charge, 500 recharge cycles. Instruction Manual and Certificate of Calibration. STANDARD KIT PRICE OPTIONAL ACCESSORIES: ADT-442 TemProbe: temperature probe, 1/8" diameter x 4" long, stainless steel. ADT-446 TemProbe: temperature probe, 1/16" diameter x 4" long, stainless steel. TRC-16 Temperature retractile cord, 6' long. GAP-125 "Sisco" gage probe for 1/8" test ports GAP-062 "Sisco" probe with guard for 1/16" test ports. MT-440K AirData Multi Temp kit with 8-position switch, 2 surface probes, 6 insertion probes and case (see MT-440K brochure). EL-USB-2-LCD Humidity, Temperature and Dew Point Data Logger with LCD FEATURES • 0 to 100%RH measurement range • -35 to +80°C (-31 to +176°F) measurement range • Dew point indication via Windows control software • USB interface for set-up and data download • User-programmable alarm thresholds for %RH & T • Status indication via red and green LEDs • High contrast LCD, with two and a half digit temperature and humidity display function • Immediate, delayed and push-to-start logging • Supplied with replaceable internal lithium battery and Windows control software • Environmental protection to IP67 This standalone data logger measures and stores up to 16,379 relative humidity and 16,379 temperature readings over 0 to 100%RH and -35 to +80°C (-31 to +176°F) measurement ranges. The user can easily set up the logger and view downloaded data by plugging the data logger into a PC's USB port and using the supplied software. Relative humidity, temperature and dew point (the temperature at which water vapour present in the air begins to condense) data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of temperature and humidity information. At the touch of a button, the user can cycle between the current temperature and humidity, along with the maximum and minimum stored values for temperature and humidity. The data logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to 1 year. The data logger is protected against moisture to IP67 when the protective cap is correctly fitted. Specifications Minimum Typical Maximum Unit Relative Humidity Measurement range 0 100 %RH Repeatability (short term) ±0.1 %RH Accuracy (overall error) ±3.0* ±5.0 %RH Internal resolution 0.5 %RH Long term stability 0.5 %RH/yr Temperature Measurement range -35 (-31) +80 (+176) °C (°F) Repeatability ±0.1 (±0.2) °C (°F) Accuracy (overall error) ±0.5 (±1) ±2 (±4) °C (°F) Internal resolution 0.5 (1) °C (°F) Dew Point Accuracy (overall error) ±1.1 (±2)** °C (°F) Logging rate every 10s every 12hr - Operating temperature range*** -35 (-31) +80 (+176) °C (°F) 1/2AA 3.6V Lithium Battery Life 1† Year * This specifies the overall error in the logged readings for relative humidity measurements between 20 and 80%RH. EL-WIN-USB (CONTROL SOFTWARE) Lascar's EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows 2000, XP, Vista & 7. The software is used to set-up the data logger as well as download, graph and export data to Excel. EL-USB-2-LCD Humidity, Temperature and Dew Point Data Logger with LCD The software allows the following parameters to be configured: • Logger name • °C, °F • Logging rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) • High and low alarms • Immediate, delayed and push-to-start logging • Display off, on for 30 seconds after button press, or permanently on • Data rollover (allows unlimited logging per ods by overwriting the oldest data when the memory is full) The latest version of the control software may be downloaded free of charge from www.lascarelectronics.com DISPLAY AND STATUS FUNCTIONS The EL-USB-2-LCD features a high contrast LCD and two bi-colour LEDs. The LCD shows logged temperature and humidity values using seven segment numbers, along with annunciators. The LCD can also show information regarding the logging status. Maximum logged value symbol Relative Humidity symbol Negative symbol Minimum logged value symbol Reading Temperature scale The LCD shows six different recorded readings, which can be cycled through using the built-in push button. The most recent logged value, maximum logged value and minimum logged value can be displayed separately for humidity and temperature. In addition, logging and alarm status is shown using two high intensity LEDs. EL-USB-2-LCD Humidity, Temperature and Dew Point Data Logger with LCD Display LCD INDICATION Display Logger Status Explanation Delayed Start Push to Start Logging Stopped This is shown when the logger is set to start at a specific data and time* This is shown when the logger is setup for "Push to start" logging This is shown when the logger is running in "LCD off" mode, and the button is pressed. The display clears again after three seconds If the logger has not been set to log and the button is pressed, three dashes are displayed for three seconds * If the logger is set to "LCD off" or "LCD on for 30 seconds" mode, then this will only be shown after the button is pressed. Otherwise the display will remain blank. LED FLASHING MODES EL-USB-2-LCD features 2 bi-colour LEDs; one LED represents temperature measurement, the other represents RH. Each is clearly marked on the logger. To save power, the status indication alternates between the two channels every 10 seconds. First you will see the status of the temperature logging, and 10 seconds later you will see the status of the RH logging, and so on. RH% °C (°F) Red/ Red/ Green LED Green LED Green double flash The data logger is not currently logging, but is primed to start at a later date and time (delayed start). Green single flash The data logger is currently logging. No alarm on the channel. Red single flash The data logger is currently logging. Low alarm on the channel. Red double flash The data logger is currently logging. High alarm on the channel. Green triple flash The data logger is full and has stopped logging. No alarm on the channel. Red triple flash The data logger is full and has stopped logging. Alarm (high, low or both). No LEDs flash The data logger is stopped, the battery is empty or there is no battery fitted. Dual Red flash (every 60 seconds) The data logger battery is running low as its voltage has dropped below 2.9V RH% °C (°F) RH% °C (°F) 10 seconds later EL-USB-2-LCD Humidity, Temperature and Dew Point Data Logger with LCD DIMENSIONS All dimensions in mm (inches) MEASUREMENT ACCURACY ± 10 ± 3.0 ± 8 ± 6 ± 4 ± 2 ± 0 0 10 20 30 40 50 60 70 80 90 100 Relative Humidity (%RH) ± 2.5 ± 2.0 ± 1.5 ± 1.0 ± 0.5 ± 0.0 -40 -20 0 20 40 60 80 Temperature (°C) BATTERY REPLACEMENT We recommend that you replace the battery every 12 months, or prior to logging critical data. The EL-USB-2-LCD does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to a PC. Only use 3.6V 1/2AA lithium batteries. Check with your supplier that the battery you are ordering is ‘press fit' and is not fitted with solder tags. Before replacing the battery, remove the EL-USB-2 from the PC. Note: Leaving the EL-USB-2 plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. 126.0 (4.9) 22.1 (0.87) 25.3 (1.04) RH (%RH) T (°C) EL-USB-2-LCD Humidity, Temperature and Dew Point Data Logger with LCD CAUTION Exposure of the internal sensor to chemical vapours such as those produced by some plastics and foamed materials may interfere with the internal sensor and cause inaccurate readings to be logged, therefore ensure that the logger is used in a ventilated area i.e. air exchange is allowed. Exposure to extreme conditions or chemical vapours will require the following reconditioning procedure to bring the internal sensor back to calibration state. 80°C (176°F) at < 5% RH for 36h (baking) followed by 20-30°C (70-90°F) at>74%RH for 48h (re-hydration) High levels of pollutants may cause permanent damage to the internal sensor. THE EASYLOG USB RANGE Each EL-USB data logger features the direct-to-USB connection and easy-to-use functionality that the range is known for. The range comprises of the following data loggers: *
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA56/W912BV-16-T-0014/listing.html)
 
Place of Performance
Address: U.S. Army Corps of Engineers, Tulsa District, ATTN: Brad Carter, PMP, SRM Technical Manager, Delivery Contact / Questions PH # 580-581-4123, Building 1945, FT SILL, Oklahoma, 73503-0159, United States
Zip Code: 73503-0159
 
Record
SN03981844-W 20160106/160104233915-c337687ff654597c7fc0eda8ab08fc9b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.