SOURCES SOUGHT
66 -- Airyscan Module for LSM 880 Carl Zeiss Microscopy
- Notice Date
- 12/11/2015
- Notice Type
- Sources Sought
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Health and Human Services, National Institutes of Health, National Heart, Lung and Blood Institute, Rockledge Dr. Bethesda, MD, Office of Acquisitions, 6701 Rockledge Dr RKL2/6100 MSC 7902, Bethesda, Maryland, 20892-7902
- ZIP Code
- 20892-7902
- Solicitation Number
- HHS-NIH-NHLBI-CSB-(HG)-SBSS-2016-035-DM
- Archive Date
- 1/2/2016
- Point of Contact
- Dorothy Maxwell, Phone: 301-435-0352
- E-Mail Address
-
maxwelld@mail.nih.gov
(maxwelld@mail.nih.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- This is a Small Business Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding: (1) the availability and capability of qualified small business sources; (2) whether they are small businesses; HUBZone small businesses; service-disabled, veteran-owned small businesses; 8(a) small businesses; veteran-owned small businesses; woman-owned small businesses; or small disadvantaged businesses; and (3) their size classification relative to the North American Industry Classification System (NAICS) code for the proposed acquisition. Your responses to the information requested will assist the Government in determining the appropriate acquisition method, including whether a set-aside is possible. An organization that is not considered a small business under the applicable NAICS code should not submit a response to this notice." LSM 880 Confocal Imaging Microscope System with Airyscan, (Specified Brand Name: Carl Zeiss Microscopy) NO REFURBISHED OR USED SYSTEMS ARE ACCEPTABLE. The capability statement should be submitted electronically (via email) to Dorothy Maxwell, Contracting Officer, at maxwelld@mail.nih.gov, on December 18, 7:30 AM, EASTERN TIME and must reference synopsis number HHS-NIH-NHLBI-CSB-(HG)-2016-035-DM. All responses must be received by the specified due date and time in order to be considered. A. BACKGROUND : The National Institutes of Health (NIH) mission is to seek fundamental knowledge about the nature and behavior of living systems and the application of that knowledge to enhance health, lengthen life, and reduce illness and disability. The National Human Genome Research Institute (NHGRI) led the National Institutes of Health's (NIH) contribution to the International Human Genome Project, which had as its primary goal the sequencing of the human genome. This project was successfully completed in April 2003. Now, the NHGRI's mission has expanded to encompass a broad range of studies aimed at understanding the structure and function of the human genome and its role in health and disease. NHGRI supports the development of resources and technology that will accelerate genome research and its application to human health. A critical part of the NHGRI mission continues to be the study of the ethical, legal and social implications (ELSI) of genome research. NHGRI also supports the training of investigators and the dissemination of genome information to the public and to health professionals. The National Human Genome Research Institute NHGRI), Cytogenetic and Microscopy Core over the past 17 years has invested significant resources to develop a state-of-the-art image acquisition and analysis facility for all NHGRI researchers to pursue and accelerate genome research. The LSM 880 2+1 plus Airyscan system allows researchers to image samples very similar to that of the existing LSM 510 NLO system, reducing the learning curve and wait time. Having the same software simplifies the Cytogenetic and Microscopy Core processes, minimizing labor and time and gives researchers the flexibility to image regularly prepared samples either confocally or through the Airyscan mode (1.7x better XY resolution at 488nm) depending on the needs of the project. B. PURPOSE AND OBJECTIVES : NHGRI Cytogenetic and Microscopy Core Facility is a high-resolution imaging core facility supporting all labs within NHGRI. Microscopy has evolved from basic light microscopes to super-resolution systems and as the technology advances so does the demand for our services. The Cytogenetic and Microscopy Core facility currently has two conventional wide-field fluorescent scopes; a deconvolution/restoration wide-field system; a Spinning Disk/TIRFconfocal system; and a LSM 510 NLO confocal system which all are in full operation. However, the LSM 510 NLO confocal system will no longer be under a service contract agreement (Zeiss has a 7 year cutoff between system versions) due to its age (12 years old). We purpose to upgrade this LSM 510 NLO to the newest LSM 880 2+1 plus Airyscan system using Zeiss' 25% trade-in promotional discount to save the government over $155,000. Since the Cytogenetic and Microscopy Core is running a system almost every day of the week totaling over 5200 hours in 2014 and projected around 5800 hours for 2015. The Cytogenetic and Microscopy Core will need an upgraded system, with a service contract in place, to meet high demand. The LSM 880 2+1 plus Airyscan system has a unique proprietary Airyscan detection unit consisting of a calibrated 32-element Gallium Arsenide Phosphide (GaAsP) PMT with typical QE >45 % (peak) and adjustable zoom optics (to accommodate different objectives). The 32-element proprietary area detector is arranged in a compound eye fashion where the central element is adjusted to lie on the optical axis. The Airyscan detector is operated in three different modes: super-resolution, variable pinhole and standard confocal. The adjustable zoom optics always ensures that a defined amount of light (1.25 airy units for super-resolution and confocal mode & 3.5 airy units for variable pinhole) is projected onto the detector. In super-resolution mode the Airyscan detector system achieves images with spatial resolutions of 140nm in XY and 400nm in Z when utilizing 488nm excitation and a 63x 1.4 NA Plan-Apochromat objective. Additionally, the system provides a real-time preview of the super-resolution image while data is being acquired. In variable pinhole mode the Airyscan allows the image optical section size of each image plane to be set after image acquisition during post processing. And in confocal mode a traditional pinhole aperture is used in addition to the detectors 32 GaAsP detection elements. All elements are then summed together to yield a traditional confocal image that can be combined with the two other PMT detectors on the system. In addition to the Airyscan detection unit, the entire 3 channel quasar detector (one GaAsP plus two standard PMTs) is liquid cooled, which improves data handling as well as overall signal to noise in the image. The one channel GaAsP and the red-shifted PMT function in both integration (digital oversampling) or photon counting mode, for extreme imaging flexibility and sensitivity when handling live cells or low expressing samples. The added new image format from 4x1 to 8192x8192 pixels with up to 16 bit depth (65536 gray values) in all PMT and GaAsP channels adds to the image quality researcher's demand. Finally, absolute linear scanner movement to ensure equal pixel dwell-times is a prerequisite for any quantitative studies. Short scanner turnaround times, > 85% of the frame time is effectively used for image acquisition and the OSCiscan for artifact-free, fast and reliable bidirectional scanning without the need of manual adjustment. C. PROCUREMENT: • LSM 880 2+1Ch NLO Ar, 561, 633, Catalog Number: 4109002147073000, Quantity: One Each. • 405 cw Laser Kit for LSM 710/780, Catalog Number: 4109009120830000, Quantity: One Each. • 405 cw Laser Kit for LSM 710/780, Catalog Number: 4109021410122000, Quantity: One Each. • Table for LSM 880 w/Airyscan 36x48, RP, Catalog Number: 4108432954814000, Quantity: One Each. • Airyscan Module for LSM 880, Catalog Number: 4109002058580000, Quantity: One Each. • Memory 32 GB (2x16) DDR3-1600 MHz ECC, Catalog Number: 4103033202000000, Quantity: Two Each. • Support for LSM 880 Axio Observer + NLO, Quantity: One Each. • C-Apochromat 40x/1,2 W Korr. FCS, Catalog Number: 4217679971711000, Quantity: One Each. • Plan-Apochromat 63x/1.40 Oil DIC f/ELYRA, Catalog Number: 4207829900799000, Quantity: One Each. • Incubator XL multi S1, Catalog Number: 4118579400000000, Quantity: One Each. • ZEN Module FRET Hardware License Key, Catalog Number: 4101361011110000, Quantity: One Each. • ZEN Module HDR ROI-Scan Hardware License, Catalog Number: 4101361007110000, Quantity: One Each. • ZEN Module Tiles / Positions HW Lic. Key, Catalog Number: 4101361025110000, Quantity: One Each. • Transmitted light detector T-PMT, Catalog Number: 4239230000000000, Quantity: One Each. • Reflector turret 6x LSM ACR, Catalog Number: • Extreme Workstation Win7 x64+30" Monitor, Catalog Number: 4109029901840000, Quantity: One Each. • Scanning Stage 130x100 STEP, Catalog Number: 4320299904000000, Quantity: One Each.   D. SCOPE OF WORK : Contractor Requirements : • The Contractor shall provide uncrating and set up of the instrument. Inspection and Acceptance Requirements: • The Contractor shall deliver instrument, computer and accessories in good working condition. The Government will verify satisfactory performance of the instrument. E. ANTICIPATED PERIOD OF PERFORMANCE : • Delivery Upon Award F. CAPABILITY STATEMENT/INFORMATION SOUGHT : Interested parties are expected to review this notice to familiarize itself with the requirements of this project. Failure to do so will be at your firm's own risk. The following information shall be included in the capability statement: A general overview of the respondents' opinions about the difficulty and /or feasibility of the potential requirement, and any information regarding innovative ideas or concepts. Information in sufficient details of the respondents' (a) staff expertise, including their availability, experience, and formal and other training; (b) current in-house capability and capacity to perform the work; (c) prior completed projects of similar nature; (d) corporate experience and management capability; and (e) examples of prior completed Government contracts, references, and other related information. The respondents' DUNS number, organization name, address, point of contact, and size and type of business (e.g., 8(a), HUBZone, etc) pursuant to the North American Industry Classification System (NAICS) code: 334516 Analytical Laboratory Instrument Manufacturing, small business size standard is 500 Employees. Any other information that may be helpful in developing or finalizing the requirements of the potential acquisition. The capability statement shall not exceed 10 single-sided pages (including all attachments, resumes, charts, etc.) presented in single-space and using a 12-point font size minimum, in either Microsoft Word or Adobe Portable Document Format (PDF), with 8-1/2 by 11 inch paper size, and 1 inch top, bottom, left and right margins. All proprietary information should be marked as such. Statements should also include an indication of current certified small business status; this indication should be clearly marked on the first page of your capability statement (preferably placed under the eligible small business concern's name and address). Responses will be reviewed only by NIH personnel and will be held in a confidential manner. G. CLOSING STATEMENT : The capability statement should be submitted electronically (via email) to Dorothy Maxwell, Contracting Officer, at maxwelld@mail.nih.gov, on December 18, 7:30 AM, EASTERN TIME and must reference synopsis number HHS-NIH-NHLBI-CSB-(HG)-2016-035-DM. All responses must be received by the specified due date and time in order to be considered. This Sources Sought Notice (SS) is for information and planning purposes only and shall not be construed as a solicitation or as an obligation on the part of the National Heart, Lung, and Blood Institute (NHLBI). The NHLBI does not intend to award a contract on the basis of responses nor otherwise pay for the preparation of any information submitted. As a result of this notice, the NHLBI may issue a Request for Quote (RFQ). THERE IS NO SOLICITATION AVAILABLE AT THIS TIME. However, should such a requirement materialize, no basis for claims against NHLBI shall arise as a result of a response to this notice or the NHLBI's use of such information as either part of our evaluation process or in developing specifications for any subsequent requirement. "Disclaimer and Important Notes. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality. No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/NIH/NHLBI/HHS-NIH-NHLBI-CSB-(HG)-SBSS-2016-035-DM/listing.html)
- Place of Performance
- Address: NIH Building 49 Confocal Core Facility, Bethesda, Maryland, 20892, United States
- Zip Code: 20892
- Zip Code: 20892
- Record
- SN03967352-W 20151213/151211233909-3e0f0970905c5e34253bc3a90f7716b1 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)