SOURCES SOUGHT
Y -- Fire Protection Upgrade, Oil Storage Room Water Mist, Libby Dam, Libby, MT
- Notice Date
- 11/18/2015
- Notice Type
- Sources Sought
- NAICS
- 238990
— All Other Specialty Trade Contractors
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, USACE District, Seattle, Attn: CENWS-CT, PO Box 3755, Seattle, Washington, 98124-3755, United States
- ZIP Code
- 98124-3755
- Solicitation Number
- W68MD953213418
- Archive Date
- 12/15/2015
- Point of Contact
- Monique Paano, Phone: 206-764-6084
- E-Mail Address
-
monique.a.paano@usace.army.mil
(monique.a.paano@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Point of Contact: Contract Specialist Monique Paano at Monique.a.paano@usace.army.mil US Army Corps of Engineers (USACE), Seattle District, is seeking interested business sources for a construction project titled: Fire Protection Upgrade, Oil Storage Room Water Mist at Libby Dam. Proposed project will be a firm fixed-price construction project. Construction magnitude is estimated to be between $500,000 and $1,000,000. 100 percent payment and performance bonds will be required. The North American Industry Classification System (NAICS) code for this project is 238990, All Other Specialty Trade Contractors, and the associated small business size standard is $15,000,000 in average annual receipts. This sources-sought announcement is a tool to identify businesses with the capability to accomplish the work and is for information/market research purposes only. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS OR BIDS, NOR A SYNOPSIS OF A PROPOSED CONTRACT ACTION UNDER FAR SUBPART 5.2. The type of solicitation to be issued will depend upon information received in response to this sources sought announcement. No reimbursement will be made for any costs associated with providing information in response to this sources sought announcement or any follow up information. Responses to this sources sought announcement will be used by the Government to make appropriate acquisition decisions. NO SOLICITATION IS CURRENTLY AVAILABLE. This is not a request to be placed on a solicitation mailing list and is not to be construed as a commitment by the Government. The results of this survey will be considered to be in effect for a period of one year from the date of this notice. Summary Scope of Work (SOW): OVERVIEW: U.S. Army Corps of Engineers (USACE), Seattle District, requires replacement of the fire protection system in the powerhouse oil storage room at Libby Dam, Montana. Project work area access is restricted by the adjacency of the Powerhouse to the Kootenai River and the dam, and restrictions on the use of cranes, lifts and other equipment in the proximity of energized overhead transmission lines, transformers and transformer bus lines. Contractor will be required to construct temporary stairs and scaffold as needed for personnel, equipment and material access to the roof surfaces. Work consists of: DEMOLITION/DECONSTRUCTION: Removal of the existing CO2 system in the oil purification room and oil storage room at Libby Dam, and provision of temporary suitable manual fire protection until the water mist system is operable and accepted. This includes but is not limited to the mechanical piping and the electrical features as well as the CO2 bottles themselves. The firing heads on the CO2 bottles, however, shall remain the property of the Government. FIRE PROTECTION INSTALLATION: Detailed design, provision, and installation of a fine water mist fire protection system for the oil purification room and oil storage room at Libby Dam. The oil purification room and oil storage room together shall be considered one zone; if water mist is triggered in either room, it is triggered in both rooms. ELECTRICAL INSTALLATION: Detailed design, provision, and installation of electrical system needed to meet the requirements of the fire suppression system being provided. REQUIREMENTS: Interested firms should submit a capabilities package, to include the following: 1. Firm's name, address (mailing and URL), point of contact, phone number, email address. 2. Business classification, i.e., Small Business (SB), Small Disadvantage Business (SDB), Woman-Owned Small Business (WOSB), Veteran Owned Small Business (VOSB), Service Disabled Veteran Owned Small Business (SDVOSB), Historically Underutilized Business Zone (HUBZone) Small Business, 8(a) Program, or Other Than Small Business (large business). 3. Three (3) to five (5) examples of past projects as the Prime Contractor for fire protection upgrades of similar size, complexity and scope completed within the last five years. Examples should include the following information: a. A description of the project, customer name, timeliness of performance, customer satisfaction, and dollar value of each project; b. Description of experience demonstrating installation of high pressure water mist fire protection systems in industrial buildings; 4. CAGE code and DUNS number. 5. Firm's Joint Venture Information, if applicable. 6. Bonding Information: a. Provide the following, on the bonding company's letterhead: (1) Bonding Limits (a) Single Bond (b) Aggregate All interested parties who believe they can meet the requirements are invited to submit, in writing, complete information describing their interest and ability to meet all requirements stated above. Prior Government contract work is not required for submitting a response under this sources sought announcement. The official Synopsis citing a solicitation number will be issued on Federal Business Opportunities (www.FBO.gov) inviting firms to register electronically to receive an electronic notification of a solicitation should one be issued. SUBMIT TO: Responses to the Sources Sought Announcement should be received no later than 2:00 pm (Pacific Time) on 30 November 2015. Submit responses to the attention of Monique Paano, Contract Specialist, by email: monique.a.paano@usace.army.mil. All interested firms must be registered in SAM (https://www.sam.gov) and remain current for the duration of the contract to be eligible for award of Government contracts.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA67/W68MD953213418/listing.html)
- Place of Performance
- Address: Libby Dam, 17877 Mt. Hwy 37, Libby, Montana, 59923-7828, United States
- Zip Code: 59923-7828