- Description
- THIS IS A REQUEST FOR INFORMATION: Study: Neurophysiological Markers and Recovery Predictors Following Repeated Mild Traumatic Brain Injuries Minimum Essential Characteristics for Mono-Phasic Dual Pulse Stimulator with Coils, Accessories and Warranty *Equipment shall come with Mono-phasic dual pulse stimulator *Equipment shall provide programmable interval paired pulse stimulation through single stimulating coil *Equipment shall be able to change inter pulse spacing from 1ms to 999ms with 0.1ms increments *Equipment shall be able to independently control power level of each stimulator *Equipment inter pulse spacing of pulses shall be able to be adjusted using either integral stimulator controls, remote control coil, or adjusted externally via triggering software *Equipment shall be compatible with all existing lab equipment coils *Equipment bundle shall include a user interface (UI) controller, a Mono-Phasic Dual Pulse Stimulator connecting module, a Mono-Phasic Dual Pulse Stimulator UI controller, and a trolley *Equipment bundle shall include two Double 70mm Remote Control Coils (one as part of the basic Stimulator package, and one additional double 70mm Remote Control Coil), a Double 40 mm Remote Coil - Branding Iron Style, a Double 40 mm Remote Coil - Flat Style, and a Double 110 mm Cone Coil Minimum Essential Characteristics for Double 70mm Remote Control Coil (D70) *D70 Remote Control Coil shall be able to induce small transient electrical current in human tissue via a magnetic field *D70 Remote Control Coil shall be able to stimulate deep human nerves easily and with less discomfort than conventional electrical stimulation. *D70 Remote Control Coil shall be compatible with mono-phasic dual pulse stimulator *D70 Remote Control Coil shall have double, figure of eight shape winding with a 70mm configuration Minimum Essential Characteristics for Double 40mm Remote Coil - Branding Iron (BI) Style (D40 BI) *D40 BI Remote Coil shall be able to induce small transient electrical current in human tissue via a magnetic field *D40 BI Remote Coil shall be able to stimulate deep human nerves easily and with less discomfort than conventional electrical stimulation. *D40 BI Remote Coil shall be compatible with mono-phasic dual pulse stimulator *D40 BI Remote Coil shall have double, figure of eight shape winding with a 40mm BI style configuration Minimum Essential Characteristics for Double 40mm Remote Coil - Flat Style (D40 FS) *D40 FS Remote Flat Coil shall be able to induce small transient electrical current in human tissue via a magnetic field *D40 FS Remote Flat Coil shall be able to stimulate deep human nerves easily and with less discomfort than conventional electrical stimulation. *D40 FS Remote Flat Coil shall be compatible with mono-phasic dual pulse stimulator *D40 FS Remote Flat Coil shall have double, figure of eight shape winding with a 40mm Flat style configuration Minimum Essential Characteristics for Double 110mm Cone Coil (D110) *D110 Remote Coil shall be able to induce small transient electrical current in human tissue via a magnetic field *D110 Remote Coil shall be able to stimulate deep human nerves easily and with less discomfort than conventional electrical stimulation. *D110 Remote Coil shall be compatible with mono-phasic dual pulse stimulator *D110 Remote Coil shall have double, figure of eight cone shape winding with a 110mm configuration Minimum Essential Characteristics for Warranty *Equipment shall be covered by a two year parts and labor warranty for stimulators *Equipment shall be covered by a one year parts and labor warranty for coils and accessories *All non-stimulator, non-coil and non-accessory equipment shall be covered by a one year parts and labor warranty PLEASE PROVIDE CAPABILITY RESPONSE TO THE POC LISTED.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/USAMRAA/DAMD17/10754310RFI/listing.html)
- Record
- SN03940058-W 20151107/151105235118-d0ca5c3134c05bb213471bb662b961f1 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |