J -- Repair of damaged and degrading chiller tube sheeting. - Attachment
- Notice Date
- 9/1/2015
- Notice Type
- Attachment
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 8 (248);Room 315, Bldg. 2;10,000 Bay Pines Blvd;Bay Pines FL 33744
- ZIP Code
- 33744
- Solicitation Number
- VA24815Q1998
- Response Due
- 9/14/2015
- Archive Date
- 10/14/2015
- Point of Contact
- David Wesley Hess
- E-Mail Address
-
hess2@va.gov<br
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- Statement of Work Lee County Healthcare Center A. General The Department of Veteran Affairs is seeking qualified contractors for a Firm-Fixed Price contract to perform the services identified in this Statement of Work (SOW). The contractor shall provide all management, supervision, labor, materials, supplies, repair parts, tools and equipment, and shall plan, schedule, coordinate, document, report and ensure the effective and economical operation of the facility as specified in this SOW. The location for performance is Lee County VA Healthcare Center, 2489 Diplomat Parkway East, Cape Coral, Florida 33909. B. Scope of Work 1)The contractor shall preform and provide with conditions in Statement of Work; up to but including and limited to: 2)The contractor shall apply and complete Ceramic Coatings to the Condenser Tube Sheets and Heads on the three Trane CVHE450 Water-Cooled CenTraVac Chillers specified in the equipment table below. QtyMfrEquipment TypeModel NumberSerial NumberLocation 1TraneWater-Cooled CenTraVac ChillerCVHE450L10E02709CH-No.1 1TraneWater-Cooled CenTraVac ChillerCVHE450L10F02787CH-No.2 1TraneWater-Cooled CenTraVac ChillerCVHE450L10F02859CH-No.3 a)DETAILED SCOPE: *Shut down chiller and lock out electrical power supply. *Isolate chiller condenser using the existing isolation valves. *Drain water from condenser vessel. *Remove both heads from condenser vessel in chiller. *Install plugs into the condenser tubes to protect tubes from coating procedures. *Prepare surface of condenser tube sheets and heads in preparation for the application of the protective coating. *If required build up areas between the tubes with chiller grade high build epoxy. *Machine tube sheet surfaces to create the desired tube sheet elevation. *Apply two coats of Chiller Grade ceramic coating to surfaces of the condenser tube sheets and condenser end bells. *Allow coating to cure per manufacturers specifications. *Reinstall both condenser heads replacing any disturbed gaskets and O-rings. *Open condenser isolation valves and refill the vessel with water. *Remove lock out from electrical power supply. *Startup chiller and verify proper operation. *Repeat process above on the second CVHE450 CH-No.2 and the third CVHE450 CH-No.3 3)All work is to be performed during normal business hours, Monday - Friday, 7am to 5pm. 4)Equipment Coverage/Warranty "Installation shall be performed per Chiller and Product manufactures recommendations; "Installation of applied product; "Disassembly and Reassembly of all equipment, parts and labor associated in task. "Contractor shall warranty all ceramic coatings applied to three CVHE450 Chiller condenser tube sheets and heads from defective installation and premature failure do to other than "normal wear". Specified by product manufacturer : "Contractor shall insure ceramic coatings applied to condenser tube sheets and heads will not degrade; thus causing harm, fouling and failure of Chiller Condenser tubes: per product manufacture. "Contractor shall insure Chemical Water Treatment applied to Chiller Condenser Water loop will not harm, degrade, effect or damage ceramic coatings; per product manufacture. Completion REPORTS 1.Contractor shall provide to the Manager the following reports of completion: A.All inspection, Service and Tests conducted per visit shall be noted in a log provided by Contractor at a location selected by Manager. B.Field Service Reports detailing work performed, goals achieved, problems found/corrected, remaining issues.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BPVAMC/VAMCCO80220/VA24815Q1998/listing.html)
- Document(s)
- Attachment
- File Name: VA248-15-Q-1998 VA248-15-Q-1998_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2291732&FileName=VA248-15-Q-1998-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2291732&FileName=VA248-15-Q-1998-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA248-15-Q-1998 VA248-15-Q-1998_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2291732&FileName=VA248-15-Q-1998-000.docx)
- Record
- SN03866319-W 20150903/150902000244-71db86ee575fecbc85ecf0560bf281be (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |