SOLICITATION NOTICE

36 -- Cryogenic System

Notice Date
8/28/2015
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333318 — Other Commercial and Service Industry Machinery Manufacturing
 
Contracting Office
Department of Energy, Fermi National Accelerator Laboratory, Fermilab, P.O. BOX 500, MAIL STOP 210 (WH4W), BATAVIA, Illinois, 60510
 
ZIP Code
60510
 
Solicitation Number
257944-SGG
 
Archive Date
9/26/2015
 
Point of Contact
Steven Gaugel, Phone: 630-840-5782
 
E-Mail Address
sgaugel@fnal.gov
(sgaugel@fnal.gov)
 
Small Business Set-Aside
N/A
 
Description
We require a cryogenic system for quick turnaround testing of superconducting microstrip resonators with the capability of expansion to testing of arrays of superconducting detector arrays fabricated on multiple 6" Silicon wafers. This system should meet the following requirements: 1) The system requires a quick cooldown to 4 Kelvin (<20 hours) 2) The system requires a sub-Kelvin cooler that can reach base temperatures of 50 mK with hold times of greater than six days at 100 mK with a cooling capacity of > 100 milli-Joules. 3) The system requires that the sub-Kelvin cooler be a removable Adiabatic Demagnetization Refrigerator (ADR) insert, to allow the system to be expanded to alternatively use an existing three-stage He4-He3-He3 sub-Kelvin fridge, already in-hand at Fermilab. 4) The system requires a two-stage pulse tube cooler (PTC) refrigerator with base temperatures of 3 and 40 Kelvin that are achievable under approximately 0.1 Watts and 30 Watts of loading, respectively. Nominally, we would like a PT415 system from Cryomech, Inc., or comparable. 5) The PTC's cold head should have vibrational isolation from the cryostat shell. 6) The PTC's motor should be electrical isolated from the cryostat shell, nominally the Cryomech, Inc. PT415-RM option, or comparable. 7) The system requires that the working volume of the 3 Kelvin space be equal to a cylinder with an approximate diameter of 17.5" and vertical height of 22". 8) The system requires temperature sensors on the 3 and 40 Kelvin stages. The criteria being reviewed will be as follows, but not limited to: Technical ability to make cryogenic system Experience of project team members Quality assurance plan Fabrication plan Delivery schedule Similar projects completed Please supply enough information fo Fermilab to evaluate your capabilities. Offers to include F.O.B. Fermilab delivery terms. Offeror to package adequately to prevent damage while in transit to Fermilab. FL-15 Request for Proposal - Instructions to Offerors (Rev. 1/07) FL-200 Fermilab Terms and Conditions - Commercial Items (Rev. 3/14) FL-103A Intellectual Property Clauses (Rev. 1/07) FL-103B Intellectual Property Clauses (Rev. 1/07) FL-6 Representations Certifications and Acknowledgements (Rev. 7/08) FL-105 Representations Regarding Proprietary Data (Rev. 7/08) FL-106 Patent Terms and Notice of Right to Request Patent Waiver (Rev. 7/08) FL-107 Rights to Proposal Data (Technical) (Rev. 1/07)
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/FERMI/FERMI/257944-SGG/listing.html)
 
Place of Performance
Address: Fermilab, Batavia, Illinois, 60510, United States
Zip Code: 60510
 
Record
SN03861142-W 20150830/150828235118-89098a0d317c830e7a280929df797320 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.