SOLICITATION NOTICE
68 -- Jasco HPLC
- Notice Date
- 8/24/2015
- Notice Type
- Presolicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Health and Human Services, National Institutes of Health, National Institute of Environmental Health Sciences, Office of Acquisitions, Office of Management, 530 Davis Drive, Durham, North Carolina, 27713, United States
- ZIP Code
- 27713
- Solicitation Number
- DL3902356
- Archive Date
- 9/12/2015
- Point of Contact
- Deitra Lunney, Phone: 919-541-0387
- E-Mail Address
-
lunney@niehs.nih.gov
(lunney@niehs.nih.gov)
- Small Business Set-Aside
- N/A
- Description
- THIS IS A NOTICE OF INTENT AND NOT A REQUEST FOR QUOTATIONS. The National Institute of Environmental Health Sciences (NIEHS), Research Triangle Park, NC intends to negotiate on a sole source basis and issue an order with Jasco Analytical Instruments, Easton, MD 21601, as it has been determined that only one responsible source and no other supplies or services will satisfy agency requirements. This request is for the purchase of the following: PU-2085i Semi-micro Bio-inert isocratic HPLC Pump (2 ea); MX-2080-32 Dynamic Mixer (1ea); DG-2080-53 Degasser (1 ea); AS-2057i Bio-inert Autosampler (1 ea); SG-101573-01 Mod fee of AS-2055 5ml Injection Version (1 ea); 6937-J041A ChromNAV 1.0 Chromatography Data System (1 ea); CG-50 Cable, 0.5M (2 ea); 5590-5174A Event Cable for LC-Net II Box (1 ea); and 0507-0830 5ml PEEK loop (1 ea). This Jasco HPLC System will provide the following capabilities: Controlling software must be easy to learn and easy to use; Must have built in degasser to remove gasses from solutions; Must be able to run three different solvents; Autosampler must have heating and cooling capabilities down to 4°C and up to 60°C; Autosampler must have both variable loop injection and full loop injection capability.5; Autosampler must have a standard injection range from 0.1 to 200uLs, but with option for 5 ml; All tubing that contacts solvents must be inert (PEEK and/or titanium components; Autosampler must have reproducibility of 0.3% RSD or less; Autosampler must be able to hold 2mL, 0.6 and 0.3mL vials; Pumps must have an automatic plunger cleaning system; Pumps must be able to program and store up to 10 time program files with up to 64 steps; Pump must have the ability to be controlled from the front panel as an individual component as well as through chromatography software; Pumps must have a flow rate range from 0.3 to 7mLs/min; and Pumps must have flow rate accuracy of ±1% or less. Award is subject to Justification for Other Than Full and Open Competition (JOFOC) Approval. This notice of intent is not a request for competitive proposals; however, all responses received within 5 days from the date of publication of this synopsis will be considered by the Government. A determination by the Government not to compete this proposed contract action based upon responses to this notice is solely with the discretion of the Government. Information received will normally be considered for the purpose of determining whether to conduct a competitive procurement. If no affirmative responses are received within 5 days of this notice to determine whether a qualified source is more advantageous to the Government, the order will be issued to Jasco. The NAICS Code/Size is 334516/500 Employees. This procurement is to be processed using Simplified Acquisition Procedures in conjunction with FAR Part 12 Commercial Item Acquisition of Commercial Items. There is no solicitation package available. For any questions regarding this announcement, please contact Deitra Lunney via email lunney@niehs.nih.gov.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/NIH/NIEHS/DL3902356/listing.html)
- Record
- SN03851948-W 20150826/150824235042-48c4625f3b217bc3cc86ed8c734b7666 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |