SOLICITATION NOTICE
Z -- MARKET SURVEY - Replacement of two old oil-fired boilers at the FAA transient housing located in Kotzebue, Alaska.
- Notice Date
- 8/6/2015
- Notice Type
- Presolicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- FEDERAL AVIATION ADMINISTRATION, AAQ-530 WN - Western Service Area (Seattle, WA)
- ZIP Code
- 00000
- Solicitation Number
- 22014
- Response Due
- 8/13/2015
- Archive Date
- 8/13/2015
- Point of Contact
- Elaina Audette, elaina.d.audette@faa.gov, Phone: 425-227-2131
- E-Mail Address
-
Click here to email Elaina Audette
(elaina.d.audette@faa.gov)
- Small Business Set-Aside
- N/A
- Description
- The Federal Aviation Administration, Northwest Mountain Region, Western Service Area, is conducting a Market Survey to improve the Government's understanding of the current marketplace and to identify capable sources. Interested sources must respond with information to confirm evidence of their qualifications and capabilities. Responses to this market survey will be used to determine if there is adequate competition to set the requirement aside for Socially and Economically Disadvantaged Businesses (SEDB/8(a)), Small Businesses, or full and open competition. This survey is being conducted in accordance with FAA Acquisition Management System (AMS) Section 3.2.1.2.1. This survey will support market research obtained from multiple sources and will be utilized for planning purposes only. This is not a Screening Information Request or Request for Proposals of any kind and the FAA is not seeking or accepting unsolicited proposals. All interested vendors are advised that the FAA will not pay for any information or any administrative costs incurred that are associated with any response received from industry in response to this Market Survey/Request for Information. Therefore, any costs associated with vendor's market Survey/Request for Information submissions will be solely at the interested vendor's expense. BRIEF SCOPE OF WORK: Replace existing Weil Mclain Model Number P-268V oil-fired boilers with like boiler (Weil Mclain Model WTGO-3 with Beckett burners). Remove and replace boiler 6 inch stove piping, replace two Extrol tanks, two Grndfos UPS 26-99 pumps, 40 gallon Pre-mix glycol tank, tiger loop, 10 honeywell zone valves and adapter plates with power heads and oil filters. RESPONSE TO THIS MARKET SURVEY: Any information provided in response to this market survey will be used for informational purposes only and will not be released. Any proprietary information submitted will be protected if appropriately marked. Vendor participation in any informational session is not a promise of future business with the FAA. To provide a response submittal, go to the market survey at SURVEY MONKEY at the following link: https://www.surveymonkey.com/r/FPBVMKG If interested in responding to the survey, please submit your response no later than THURSDAY, AUGUST 13TH at 5:00PM Pacific Time. Market survey point of contact is Elaina Audette, FAA Contracting Officer. Email: elaina.d.audette@faa.gov, Phone: (425) 227-2131. If you're viewing this announcement from a source other than Federal Aviation Administration Contract Opportunities (FAACO), visit https://faaco.faa.gov/index.cfm/announcement/view/22014 to view the original announcement.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOT/FAA/NMR/22014/listing.html)
- Record
- SN03826524-W 20150808/150806234950-1f1c016a43c81bd597fbe31f7ac92653 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |