AWARD
Z -- The contractor shall provide all labor, supplies, supervision, and equipment required to provide for the Maintenance of 3 High Voltage Sub-Stations at Naval Support Activity, Mechanicsburg, PA
- Notice Date
- 8/5/2015
- Notice Type
- Award Notice
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- N40085 NAVFAC Mid-Atlantic, PWD PA 4921 S. Broad Street Building 1 Philadelphia, PA
- ZIP Code
- 00000
- Solicitation Number
- N4008515Q7532
- Response Due
- 4/13/2015
- Archive Date
- 8/20/2015
- Point of Contact
- Aaron Koumaras
- E-Mail Address
-
koumaras@navy.mil
- Small Business Set-Aside
- Total Small Business
- Award Number
- N40085-15-P-7532
- Award Date
- 7/20/2015
- Awardee
- CABLE TESTING SER VICES, LLC<br />
- Award Amount
- $17,535.00
- Line Number
- CLIN 0001
- Description
- THIS CONTRACT SHALL BE FIRM FIXED PRICE SERVICE PROCUREMENT AND IN ACCORDANCE WITH THE SIMPLIFIED ACQUISITION PROCEDURES AUTHORIZED BY FAR PART 13. THIS EFFORT WILL BE PROCURED AS IS 100% SMALL BUSINESS UNDER NAICS 238210; WITH A SIZE STANDARD OF $15,000,000.00. GENERAL DESCRIPTION: a. The contractor shall provide all labor, material and equipment to perform the requirements described in this specification. b. The contractor shall provide all labor, supplies, supervision, materials, equipment, and transportation unless otherwise specified herein, required for the: 1) Cleaning and calibration of sixty-eight (68) relays in accordance with Attachment 4, Section 2. 2) Inspection, Cleaning and testing of twenty three (23) air and vacuum insulated circuit breakers in accordance with Attachment 4, Sections 3 and 4. 3)Inspection and cleaning of forty-six (46) substation equipment cubicles in accordance with Attachment 4, Section 5. 4) Inspection and testing of four (4) battery banks and chargers in accordance with Attachment 4, Section 6. 5) Sampling and testing of four (4) transformers ™ insulating oil in accordance with Attachment 4, Section 7. 6) Provide power dissipation factor testing of four (4) transformers and twelve (12) lightning arrestors in the main substation. Testing to be performed on the following: (a) One (1) 15000/20000 KVA Transformer (Oil Filled) (b) Two (2) 3750/5000 KVA Transformers (Oil Filled) (c) One (1) 7500/9375 KVA Transformer (Oil Filled) Testing is to be performed using approved Doble, AVO or similar equipment. A full report of the findings shall be provided to the Contracting Officer for submittal to the Utilities foreman. 7) Preparation of inspection reports in accordance with Attachment 4, Sections 2 through 10. 8) Miscellaneous equipment repair, cleaning and lubrication as required in accordance with Attachment 4, Section 8. c. All System interruptions to be coordinated with base Fire Dept., security and Public Works Department in accordance with Attachment 4, Section 1.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62472PH/N4008515Q7532/listing.html)
- Record
- SN03825272-W 20150807/150805235545-f58e3a4ac1f0aee5d3b878bdd6c93b25 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |