SOLICITATION NOTICE
66 -- REQUEST FOR QUOTATION FOR A GAS ANALYZER WITH POWERLAB DATA AQUISITION SYSTEM AND LABCHART PRO
- Notice Date
- 7/31/2015
- Notice Type
- Presolicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- US Army Medical Research Acquisition Activity, ATTN: MCMR-AAA, 820 Chandler Street, Frederick, MD 21702-5014
- ZIP Code
- 21702-5014
- Solicitation Number
- 0010713350RFQ
- Response Due
- 8/10/2015
- Archive Date
- 9/29/2015
- Point of Contact
- Tonja Ray Harris, 301 619 1362
- E-Mail Address
-
US Army Medical Research Acquisition Activity
(tonja.r.harris.mil@mail.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- This a request for quotation for a Gas Analyzer with Power Lab Data Acquisition System and Labchart Pro. The point of contact for this requirement is CPT Ray Harris at tonja.r.harris.mil@mail.mil. Please respond by the established dues date. The MECs below are for a quantity of 1- Gas Analyzer and 1- Powerlab and LabChart Pro. The gas analyzer plus powerlab System MUST: 1.The powerlab system must have at least 16 analog input channels for simultaneous acquisition and recording of multiple physiological parameters. 2.The frequency response and sampling rate of the System must be high enough (desired frequency response is 25 kHz and desired sample rate is 200 kHz) to ensure the signal integrity. The analog-to-digital resolution must be at least 16 bits. 3.The system must have at least 4 inputs which can be configured as single ended or differential, which allow the use of different input connectors in addition to the BNC connector. 4.The System must allow us to access the data files generated from the current data acquisition system (the file format is.adicht). 5.The resolutions of the gas analyzer must be at least 0.01% for oxygen and 0.1% for carbon dioxide. Also, the response time must be approximately 440 ms for carbon dioxide and 430 ms for oxygen at a flow rate of 200 ml/min. 6.The gas analyzer must be compatible with our current data acquisition system (Powerlab 16/30, AD Instruments). 7.The gas analyzer plus powerlab System must be close to those of the current system (ML206 gas analyzer and PowerLab 16/30 Channel Recorder from AD Instruments) in our lab to ensure the consistency of our data generated from the old and new system.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/USAMRAA/DAMD17/0010713350RFQ/listing.html)
- Place of Performance
- Address: Walter Reed Army Institue of research (WRAIR) Robert Grant Avenue Bldg. 503 Silver Spring MD
- Zip Code: 20910-7500
- Zip Code: 20910-7500
- Record
- SN03818960-W 20150802/150731234743-abd69a325cd59e0855b96c3d84b19714 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |