Z -- NOSC KC Lightning Protection and Blind Replacement

Notice Date
7/29/2015
 
Notice Type
Award Notice
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
N69450 NAVFAC Southeast, PWD Mid-South 5722 Integrity Drive Building 455 Millington, TN
 
ZIP Code
00000
 
Solicitation Number
N6945015R6228
 
Archive Date
8/29/2015
 
Point of Contact
Michael Terrell
 
E-Mail Address
l.w.terrell@navy.mil
 
Small Business Set-Aside
Partial Small Business
 
Award Number
N6945015C6228
 
Award Date
7/28/2015
 
Awardee
Infinite Energy Construction (DUNS 014255249)<br />
 
Award Amount
$128,226.25
 
Line Number
0001
 
Description
The work includes furnishing all labor, transportation, supervision, material, and equipment required to design and install lightning protection for the main NOSC building; install roller shades throughout the facility; and incidental related work. WINDOW SHADES Install new roller screen shades for all windows throughout the NOSC. There are approximately 230 windows; however, all quantities shall be field verified by the contractor prior to bid. The Contractor is responsible for field measurement prior to ordering. The color will be chosen by the NOSC and approved by the NAVFAC construction manager prior to ordering by the Contractor. The Contractor shall remove and dispose of all existing window coverings. LIGHTING PROTECTION SYSTEM Design and install a Franklin lightning protection system consisting of the latest UL Listed products of a manufacturer regularly engaged in production of lightning protection system components. Comply with NFPA 70, NFPA 780, and UL 96. Lightning protection system consists of air terminals, roof conductors, down conductors, ground connections, grounding electrodes and ground ring electrode conductor. Bond secondary conductors with grounded metallic parts within the building. Make interconnections within side-flash distances at or below the level of the grounded metallic parts. Include bonding of all items located on the roof, including, but not limited to roof drains, vent piping, exhaust fans and HVAC equipment. If applicable, ground shall tie into the steel structure of the building.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N40083A/Awards/N6945015C6228.html)
 
Record
SN03816057-W 20150731/150730000625-9e7aa8605b09d2dbc8f33c14b96f495b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.