SOLICITATION NOTICE
99 -- STORAGE TENT
- Notice Date
- 7/27/2015
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 493110
— General Warehousing and Storage
- Contracting Office
- RCO Grafenwoehr (PARC Europe, 409th CSB), UNIT 28130, APO, AE 09114
- ZIP Code
- 09114
- Solicitation Number
- W912PB-15-T-3187
- Response Due
- 8/10/2015
- Archive Date
- 9/25/2015
- Point of Contact
- Nikkeyla Barbee, 0175615361
- E-Mail Address
-
RCO Grafenwoehr (PARC Europe, 409th CSB)
(nikki.barbee@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Insulated storage tent. The storage structure shall have the following dimensions: 25 meters long, 15 meters wide and a height at the gutters of 5.2 meters. The segments shall measure 5 meters. The structural components must consist out of aluminum profile, four notch style and anchor plates for the floor mounting utilizing ground pegs. The corner and ridge connection pieces shall be manufactured from galvanized steel. The roof structure shall feature a 18 degree pitch with connections from the roof to the side walls. The frame structure must meet the requirements of DIN EN 13782 and a verifiable static calculation must be supplied. The roof shall be covered by sandwich type thermo roof elements DL 120, built from galvanized steel on both sides with a 80mm polyurethane foam core, painted gray/white RAL 9002, meeting or exceeding an insulation rating of K-factor 0, 5 W/m K. The side walls shall consist of sandwich type thermo panels built from galvanized steel on both sides with a 80mm polyurethane core, horizontal mounted and sealed against floor. The panels must meet or exceed an insulation rating of a U factor 0,58 W/m K and a R factor of 1,56 m k/W. The panels shall be painted gray/white RAL 9002 and interconnected with quote mark tongue and groove quote mark design including seal between the panels. The panels shall meet the fire resistant rating according DIN 4102 class 1. The structure must be accessible from the long side via roll up doors. Six roll up doors meeting the following specifications, installed in the long side of the structure must be included in the project. Dimensions of doors 4, 85 meters wide by 3,70 meters in height. The roll up doors shall be manufactured out of a type 6010 aluminum/ Steel profile. Mounts and guide rails must be manufactured from galvanized steel. The opening and closing mechanism shall be electrically operated (400V, 50hz), controlled by a selector switch for each door with an quote mark Open, Close and Stop quote mark function. In addition, each door must feature an manual emergency opening device in case of power failure. The roll up doors shall feature an catch mechanism and a quote mark dead man quote mark switch reacting to constant pressure. The electrical control circuit shall run on 24 Volt, protected against moisture according to IP 54 standard. The bottom panel of the door segments must be equipped with a neoprene rubber seal to compensate uneven ground. The structure must be equipped with a man door at the gable side of the building, or alternately integrated into one of the roll up doors, to gain initial access to the building.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/8c239a4f6429d2d79b05796823dd26c5)
- Place of Performance
- Address: RCO Grafenwoehr (PARC Europe, 409th CSB) UNIT 28130, APO AE
- Zip Code: 09114
- Zip Code: 09114
- Record
- SN03812202-W 20150729/150727235839-8c239a4f6429d2d79b05796823dd26c5 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |