SOLICITATION NOTICE
65 -- UV-VIS-NearInfrared Spectrophotometer
- Notice Date
- 6/24/2015
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- ACC-APG - Adelphi, ATTN: AMSRD-ACC, 2800 Powder Mill Road, Adelphi, MD 20783-1197
- ZIP Code
- 20783-1197
- Solicitation Number
- W911QX-15-T-0165
- Response Due
- 7/2/2015
- Archive Date
- 8/23/2015
- Point of Contact
- Jamie White, 3013941615
- E-Mail Address
-
ACC-APG - Adelphi
(jamie.n.white2.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. C.1 Objective the government requires : One (1) Ultraviolet-Visible -NearInfrared Spectrophotometer that meets the following requirements: C.1.1 Doubled beam, double monochromator ratio recording spectrophotometer that is controlled through a PC with minimum measurement band from 200 to 3300 nm. C.1.2 All changing of sources and detectors required to cover the measurement band shall be automatic. C.1.3 Full integrated transmission and absorbance data collection modes with real-time spectral display and status. C.1.4 Minimum sample compartment dimensions of 6 quote mark wide x 10 quote mark deep x 8 quote mark high with a minimum distance between beams of 6 quote mark. C.1.5 The photometric range greater than or equal to 8A (absorbance units) throughout the measurement band. C.1.6 The photometric accuracy less than plus or minus 0.0003 A for absorption units of 1.0A or lower and less than plus or minus 0.003 for absorptions units of 2.0A C.1.7 Wavelength resolution less than or equal to 0.05 nm in the UV/visible band and less than or equal to 0.20 nm in the near-infrared band. C.1.8 Wavelength accuracy less than or equal to plus/minus 0.1 nm in the UV/visible band and less than or equal to plus/minus 0.4 nm in the near-infrared band. C.1.9 Maximum scan rate equal to or greater than 2000 nm/min. C.1.10 Operate on standard 115V/60Hz U.S. voltage. C.1.11Include all necessary software to operate the spectrophotometer and collect data. C.1.12 Include universal transmission holders. C.2 Objective the government requires One (1) Infrared Spectrometer that meets the following requirements: C.2.1 Spectrometer that is controlled through a PC with minimum measurement band from 1.5 to 25 um (6,666-400 cm-1). C.2.2 All changing of sources and detectors required to cover the measurement band shall be automatic. C.2.3 There shall be full integrated transmission and absorbance data collection modes with real-time spectral display and status. C.2.4The spectrometer shall have a large sample compartment to accommodate filter sizes up to 6 quote mark in diameter C.2.5 Measurement accuracy less than or equal to 0.1%T for low transmission measurements and less than or equal to 0.25%T for high transmission measurements (as measured to a Germanium National Institute of Standards and Technology (Ge NIST) standard). C.2.6 Spectral resolution less than or equal to 1 cm-1 and automatically selected to optimize measurement accuracy. C.2.7 Wavelength accuracy less than or equal 0.1 cm-1 in the middle of the measurement band. C.2.8 Operate on standard 115V/60Hz U.S. voltage. C.2.9 Include all necessary software to operate the spectrometer and collect data. C.2.10 Include universal transmission holders.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/15a7da02ce63b70dffd090cf1d5ac6e4)
- Place of Performance
- Address: ACC-APG ATTN: AMSRD-ACC, BLDG 1856 White Sands Missile NM
- Zip Code: 88002
- Zip Code: 88002
- Record
- SN03775697-W 20150626/150625000056-15a7da02ce63b70dffd090cf1d5ac6e4 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |