Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 06, 2015 FBO #4943
MODIFICATION

Y -- Pipe Cable System Replacement, Fort Randall Dam, South Dakota

Notice Date
6/4/2015
 
Notice Type
Modification/Amendment
 
NAICS
237130 — Power and Communication Line and Related Structures Construction
 
Contracting Office
USACE District, Omaha, 1616 Capital Ave, Omaha, NE 68102-4901
 
ZIP Code
68102-4901
 
Solicitation Number
W9128F-15-R-0014
 
Response Due
7/14/2015
 
Archive Date
8/13/2015
 
Point of Contact
Polina Poluektova, 402-995-2091
 
E-Mail Address
USACE District, Omaha
(polina.a.poluektova@usace.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
On or about 10 June 2015, this office will issue Request for Proposals for construction of the Pipe Cable System Replacement, Fort Randall Dam, SD. The solicitation will close on or about 14 July 2015. This solicitation is set-aside for Small Business interests. A site visit date and time will be issued with the advertisement package. DO NOT submit requests for plans and specifications to the site visit personnel listed above. See 'Obtaining Solicitation Documents' below. _______________________________________________________________________________ Project Description: (Approx. quantities) The purpose of this project is to replace the existing oil filled cable system at the Fort Randall project. The four existing oil-filled 84MVA/ 4,000A feeders in the Power Tunnel from the powerhouse to the switchyard will be replaced with four solid dielectric EPR MV-105 118MVA/5,000A feeders, with 3,000A capacity per circuit configured as two circuits per feeder to meet the needs of the projected main unit uprates. Contractor design will be specified for the details of connecting the new terminations to the existing bus, and for the supplementary supports to be installed on the existing support structures to hold the additional cable trough. The estimated construction cost of this project is between $7,500,000 and $10,000,000. _______________________________________________________________________________ The Contractor will be required to commence work within 1 days after notice to proceed and complete the work 950 calendar days after receipt of Notice to Proceed. Provisions will be included for liquidated damages in case of failure to complete the work in the time allowed. Performance and payment bonds will be required. Bonding documents including the power of attorney shall bear an original signature by an officer of the surety. Bidders (Offerors): Please be advised of on-line registration requirement for Representations and Certifications Application (ORCA) is now located in System for Award Management (SAM) database https://www.sam.gov/portal/public/SAM/. Representations and certifications are required to be updated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective until one year from date of submission or update to SAM. Obtaining Solicitation Documents: Solicitation documents will be posted to the web via Federal Business Opportunities (www.fbo.gov). Find solicitation announcement in Fed Biz Opps (www.fbo.gov) 1.Use the 'Quick Search' to locate the project (by entering the solicitation number) or use the advanced search features offered in the 'Find Opportunities' (large arrow in the middle of the page) or use the 'Opportunities' tab followed by the 'Advanced Search' tab. 2.By using the 'login' feature, it allows additional search features and allows you to keep your searches. Login might be required on some solicitations that are considered restricted. 3.Once you have located your project, click on link to solicitation to view the project. Files may be downloaded from the column on the right side reading 'All Files' or from the 'Packages' tab. 4.If you want other vendors, sub-contractors or contractors to contact you, click on the 'Interested Vendors' tab and then 'Add me to Interested Vendors' link at the bottom of the page. Questions regarding contractual matters should be made to: Polina Poluektova 402- 995-2091. Telephone calls regarding Small Business matters should be made to: 402- 995-2910. Telephone calls on contents of drawings and specifications should be made to the Project Manager at: 402-995-2719 or Specification Section at: 402-995 2184.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA45/W9128F-15-R-0014/listing.html)
 
Place of Performance
Address: USACE Fort Randall 399 Powerhouse Rd Picksotwn SD
Zip Code: 68102-4901
 
Record
SN03753585-W 20150606/150604235853-53387bf00541d0c218da15d1f186c567 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |