DOCUMENT
65 -- Viatorr Endoprosthesis (508-15-2-2089-2786) - Attachment
- Notice Date
- 5/27/2015
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;VISN 7 Network Contracting Office;LaVista Business Park - Bldg A;2008 Weems Road;Tucker GA 30084
- ZIP Code
- 30084
- Solicitation Number
- VA24715Q0722
- Response Due
- 6/5/2015
- Archive Date
- 6/8/2015
- Point of Contact
- Wallace J. Edmondson III
- E-Mail Address
-
ta
- Small Business Set-Aside
- N/A
- Description
- STATEMENT OF WORK A.GENERAL INFORMATION 1. Title of Project: Transvenous Intrahepatic Portosystemic Shunt Procedures requiring a covered stent for new services offered in Interventional Radiology. 2. Scope of Work: The contractor shall provide all resources necessary to accomplish the deliverables described in this statement of work (SOW), except as may otherwise be specified. The lined portion stent should be able to cover the entire tract creation from the liver parenchyma, portal vein junction to the hepatic vein ostium. 3. Background: Effectively treating portal hypertension in both the creation and revision of TIPS procedures. All prior TIPS procedures ordered at the Atlanta VA have been fee- based out to other facilities, however due to the new circumstances such as a new credentialed Physician and the anesthesia compliant Interventional Radiology procedure suite, all TIPS procedures are a newly offered service. 4. Period of Performance: 2015- 5. Type of Contract: Firm Fixed Price B.DELIVERY LOCATION: ATTN: Brackita Washington Logistics Warehouse, Veterans Affairs Medical Center, 1670 Clairmont Rd. Decatur, Ga. 30033 C.SCHEDULE OF DELIVERABLES/INSTALLATION Supplies will delivered upon purchase to Logistics warehouse, Attn: Brackita Washington. Upon receipt we will deliver to Interventional Radiology department. This is to be a one-time initial purchase, and the product will effectively be replaced upon use through the consultation process that is currently in use by the Prosthetics department. D.NETWORK: Network access not required. E.ITEM DESCRIPTION: *ITEM DESCRIPTIONUNIT OF ISSUEQUANTITYCOST PER ITEM VIATORR ENDOPROSTHESIS 10MM/4/2CMEA2 VIATORR ENDOPROSTHESIS 10MM/6/2CMEA2 VIATORR ENDOPROSTHESIS 10MM/8/2CMEA2 F.SALIENT CHARACTERSITICS: "Reduced permeability ePTFE graft lining minimizes transmural permeation of bile and mucin (which are common causes of patency loss) "Minimizes tissue ingrowth into the graft for ease of surgical dissection during liver transplantation. "Offers improved radial compression strength "Ensures secure anchoring with minimal kinking and tissue deformation. "Unlined "chain link" segment of the device allows for nutrient portal perfusion. "Non bare metal stent "Flexible Mesh "Various sizes to meet patient needs
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AtlVAMC/VAMCCO80220/VA24715Q0722/listing.html)
- Document(s)
- Attachment
- File Name: VA247-15-Q-0722 VA247-15-Q-0722.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2070437&FileName=VA247-15-Q-0722-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2070437&FileName=VA247-15-Q-0722-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA247-15-Q-0722 VA247-15-Q-0722.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2070437&FileName=VA247-15-Q-0722-000.docx)
- Place of Performance
- Address: Department of Veterans Affairs;Atlanta VA Medical Center;1670 Clairmont Road;Decatur, GA
- Zip Code: 30033-6137
- Zip Code: 30033-6137
- Record
- SN03743188-W 20150529/150527235155-9fcee34b91e5249a0ba3d349a90cd4e6 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |