MODIFICATION
66 -- HELIUM STORAGE TANK
- Notice Date
- 4/8/2015
- Notice Type
- Modification/Amendment
- NAICS
- 339999
— All Other Miscellaneous Manufacturing
- Contracting Office
- Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B130, Gaithersburg, Maryland, 20899-1410, United States
- ZIP Code
- 20899-1410
- Solicitation Number
- SB1341-15-RQ-0232
- Archive Date
- 5/14/2015
- Point of Contact
- Lynda M Roark, Phone: 3019753725, Patrick K Staines, Phone: (301)975-6335
- E-Mail Address
-
Lynda.Roark@nist.gov, patrick.staines@nist.gov
(Lynda.Roark@nist.gov, patrick.staines@nist.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- AMENDMENT 0001: THE PURPOSE OF THIS AMENDMENT IS TO EXTEND THE DUE DATE FOR QUOTATIONS AND ANSWER QUESTIONS: THE DUE DATE FOR QUOTATIONS IS EXTENDED AS FOLLOWS: FROM: APRIL 16, 2015 TO: APRIL 29, 2015 NOT LATER THAN 3:30 PM EASTERN TIME. THE FOLLOWING QUESTIONS ARE HEREBY ANSWERED AND ARE PART OF THIS SOLICITATION AS FOLLOWS: 1 - Are all items on drawing #002-3727 to be "Government Supplied"? If so will the shell sections, item #2, be supplied as flat plate or will they be rolled to size? Will items #1 & #3 have the edges beveled (weld prepped)? Will item #2 be provided rolled to size? Answer: 1. The plates in question are on 002-2936, this is what the vendor is to supply/make. Drawings 002-2937(not 002-3727), 002-2938, 002-2939 & 002-2940 are the pieces that are supplied by the government. They are shown on 002-2936 so that the vendor will know where to weld them onto the tank they will make. Everything else on 002-1936 is supplied by the vendor, not the government( shell sections, item #2, etc.). From the spec, The helium storage tank shall have an internal volume of not less than 15,700 gallons. The helium storage tank shall have four penetrations as shown in (002-2936). Four assemblies supplied by the government will be welded in these four penetrations, (002-2937, 002-2938, 002-2939 and 002-2940) shown on Section B-B, Section C-C & Section D-D of 002-2936. 002-3727 shows the construction(not 002-2937) of the vessel. 2 - Please provide outside diameter of the tank. Answer: Diameter is 8 feet, based on size of the rolled plates. All other terms and conditions remain unchanged.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/SB1341-15-RQ-0232/listing.html)
- Place of Performance
- Address: 100 Bureau Drive, Gaithersburg, Maryland, 20899, United States
- Zip Code: 20899
- Zip Code: 20899
- Record
- SN03693835-W 20150410/150408235601-ee2a7a27e5f9ce790ee277b9d5b89471 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)