Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 10, 2015 FBO #4885
MODIFICATION

66 -- HELIUM STORAGE TANK

Notice Date
4/8/2015
 
Notice Type
Modification/Amendment
 
NAICS
339999 — All Other Miscellaneous Manufacturing
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B130, Gaithersburg, Maryland, 20899-1410, United States
 
ZIP Code
20899-1410
 
Solicitation Number
SB1341-15-RQ-0232
 
Archive Date
5/14/2015
 
Point of Contact
Lynda M Roark, Phone: 3019753725, Patrick K Staines, Phone: (301)975-6335
 
E-Mail Address
Lynda.Roark@nist.gov, patrick.staines@nist.gov
(Lynda.Roark@nist.gov, patrick.staines@nist.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
AMENDMENT 0001: THE PURPOSE OF THIS AMENDMENT IS TO EXTEND THE DUE DATE FOR QUOTATIONS AND ANSWER QUESTIONS: THE DUE DATE FOR QUOTATIONS IS EXTENDED AS FOLLOWS: FROM: APRIL 16, 2015 TO: APRIL 29, 2015 NOT LATER THAN 3:30 PM EASTERN TIME. THE FOLLOWING QUESTIONS ARE HEREBY ANSWERED AND ARE PART OF THIS SOLICITATION AS FOLLOWS: 1 - Are all items on drawing #002-3727 to be "Government Supplied"? If so will the shell sections, item #2, be supplied as flat plate or will they be rolled to size? Will items #1 & #3 have the edges beveled (weld prepped)? Will item #2 be provided rolled to size? Answer: 1. The plates in question are on 002-2936, this is what the vendor is to supply/make. Drawings 002-2937(not 002-3727), 002-2938, 002-2939 & 002-2940 are the pieces that are supplied by the government. They are shown on 002-2936 so that the vendor will know where to weld them onto the tank they will make. Everything else on 002-1936 is supplied by the vendor, not the government( shell sections, item #2, etc.). From the spec, The helium storage tank shall have an internal volume of not less than 15,700 gallons. The helium storage tank shall have four penetrations as shown in (002-2936). Four assemblies supplied by the government will be welded in these four penetrations, (002-2937, 002-2938, 002-2939 and 002-2940) shown on Section B-B, Section C-C & Section D-D of 002-2936. 002-3727 shows the construction(not 002-2937) of the vessel. 2 - Please provide outside diameter of the tank. Answer: Diameter is 8 feet, based on size of the rolled plates. All other terms and conditions remain unchanged.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/SB1341-15-RQ-0232/listing.html)
 
Place of Performance
Address: 100 Bureau Drive, Gaithersburg, Maryland, 20899, United States
Zip Code: 20899
 
Record
SN03693835-W 20150410/150408235601-ee2a7a27e5f9ce790ee277b9d5b89471 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.