Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 08, 2015 FBO #4883
SPECIAL NOTICE

66 -- 1 Year standard Service and Maintenance agreement model

Notice Date
4/6/2015
 
Notice Type
Special Notice
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Global Strike Command, 341 CONS, 7015 Goddard Drive, Malmstrom AFB, Montana, 59402, United States
 
ZIP Code
59402
 
Solicitation Number
F2W4A13121A001
 
Archive Date
4/25/2015
 
Point of Contact
Zaire Naylor, Phone: 406-731-3041, Alexander E. Smith, Phone: (406)731-4677
 
E-Mail Address
zaire.naylor@us.af.mil, alexander.smith.12@us.af.mil
(zaire.naylor@us.af.mil, alexander.smith.12@us.af.mil)
 
Small Business Set-Aside
N/A
 
Description
STATEMENT OF WORK FOR CHEMISTRY ANALYZER MALMSTROM AIR FORCE BASE, MONTANA 1. SCOPE: The contractor shall provide scheduled preventive maintenance inspections (PMis), calibrations, and on-site emergency services for equipment listed below. Service shall include travel, labor, parts, materials (excluding user consumable supplies), manufacturer's authorized field modifications and equipment updates, technical data, and the required tools and test equipment. Services shall be performed during normal duty hours of 0800 to 1700, Monday through Friday, excluding Federal, local, and company holidays. Response time shall not exceed 24 continuous clock hours. Description : Chemistry Analyzer Manufacturer: Ortho-Clinical Diagnostics Model: Vitrous 5, 1FS Serial#: 34002244/134002244 Location : Bldg 2040 Room: Laboratory, 341st Medical Group, Malmstrom AFB 2. REQUIRED SERVICES: a. Preventive Maintenance Inspections (PMis). These inspections include checks for proper operation, detection and correction of incipient failures, actions pertaining to periodic technical inspections, lubrications, adjustments, calibrations, interior cleaning, and replacement of worn parts. (1) One annual PMI shall be performed at a mutually agreed upon schedule between Ortho-Clinical Diagnostics and the 341st Medical Group. (2) PMis shall include: (a) Consulting with equipment operators regarding equipment performance (b) Performing operational checks on all systems and correcting noted deficiencies. (c) Replacing worn or defective parts (those parts that may fail before the next PMI) (d) Cleaning and lubricating in accordance with manufacturer 's service manual. (e) Verifying the system's calibration (3) Scheduled PMis shall be coordinated with the Malmstrom Laboratory and the contracting officer's representative (COR) one week in advance. b. Emergency Service Calls. On-site emergency service is the repair necessary to return the system to its intended functional state of operation. The contractor will provide on-site repair to correct all malfunctions that occur. The service technician will continue uninterrupted service until the system is operational according to manufacturer 's specifications. Travel and overtime will be included at no additional cost. All tools, test equipment, parts, and supplies will be the responsibility of the contractor. Page 1 of 3 25 Feb 2015 (1) Response time to emergency service requests shall not exceed 24 continuous clock hours, excluding weekends and holidays. (2) The equipment shall be repaired within 24 continuous clock hours after arrival to the equipment site, excluding Federal, local, and company holidays. The need for unavailable parts will suspend the time limit until parts are obtained. These parts shall be obtained in the swiftest manner at no additional cost to the government. c. Equipment Updates. The contractor shall furnish and install all software update and equipment modifications provided by the manufacturer. These updates are provided at no additional cost and installed no later than the next PMI or emergency visit. 3. ADMINISTRATION: a. The contractor will receive PMI and on-site emergency service requests from Medical Equipment Repair (MER). Upon arrival, the contractor will contact MER before performing any work specified in this agreement. b. The service technician will prepare a service report for each visit and obtain the signature of a supervisor within the Laboratory or by a COR certifying acceptance of services performed. The report shall describe the service performed in sufficient detail and include the following: service. (1) System name, model and serial number, location, and site number if applicable (2) Purpose of the visit or description of the malfunction (3) Start/Stop times and dates (4) Break down of travel and labor hours (5) Description of all services rendered (6) Complete list ofreplacement parts used and their costs (7) Attached copy of test records or checklist used to prove completion of PMI (8) Signatures of the person performing the service and of the person accepting the c. The contractor will deliver one copy of the service report to the MER office located in building 2040, room 8232. d. Replacement Parts. The contractor shall use only new original or factory refurbished replacement parts. The service personnel should carry or have the manufacturer's "recommended stock" of parts for the system readily available. e. Training/Experience. Service technicians should have received factory training on this or like systems. Individuals should be actively engaged in repairing like systems for normal operation functions. Individuals should be actively engaged in repairing like systems for 12 of the last 18 months. f. Test Equipment. The contractor shall ensure that all test equipment used has been calibrated according to manufacturer 's specification against a traceable standard. Page 2 of 3 25 Feb 2015 g. Technical Data. The contractor 's service personnel will maintain a complete file of technical documentation for the system serviced to include update memos, and service history records. 4. CONTRACTING OFFICERS REPRESENTATIVE: The designated representatives authorized to place calls for this agreement will be MER or Contract Services personnel. CORs may be contacted at: Bldg 2040 Contract Services/Medical Equipment Repair 341st MOSS I SGSM 7300 N. Perimeter Rd Malmstrom AFB, MT 59402 DSN: 632-4375/4415 Com: 1-406-731-4375/4415 FAX: 1-406-731-2577 Page 3 of 3 25 Feb 2015
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/31d8bd6a4fb50dadba3b068ddd6fe0fc)
 
Place of Performance
Address: Malmstrom AFB, Great Falls, Montana, United States
 
Record
SN03690470-W 20150408/150406234909-31d8bd6a4fb50dadba3b068ddd6fe0fc (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.