Notice Date
12/19/2014
 
Notice Type
Attachment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of Veterans Affairs;Dayton VA Medical Center;3140 Governor ™s Place Blvd. Suite 210;Kettering OH 45409-1337
 
ZIP Code
45409-1337
 
Solicitation Number
VA25015R0024
 
Response Due
12/29/2014
 
Archive Date
1/12/2015
 
Point of Contact
Jason E Lawson
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Project 541-15-502 - Door Operators for Entrance Doors to Module C&D 1. Background. Provide automatic doors for the entrance to Modules C&D. The automatic doors shall enable the Modules to be ADA compliant. 2. Scope. Install door operators on the front doors to Module C&D to enable them to be ADA compliant. Power for door operators will be provided by the VAMC Electrical Shop. Quantity - Material(s) 2 - DUAL EGRESS LOW ENERGY DOOR OPERATORS - 72" - CLEAR FINISH 4 - DOOR MOUNTED SAFETY SENSORS 4 - PUSH PLATES (CUT IN BY VA) 4 - ELECTRIC LATCH RETRACTION PANIC DEVICES (FIRE RATED) 2 - POWER SUPPLY All cables are to be marked on both ends at or near the termination point so as to be easily traced in the future. All cables are to be labeled with Brady wire labels or equal. Any and all additional control wire and or cables for modification to existing wiring will be included in the scope of work. 3. Security Requirements Security: Contractor is also responsible for security badges of all contractor/subcontractor personnel. Every worker must have a badge and form of identification when working on VA property, and is subject to VA security checks and enforcement actions while working on VA property. 4. Safety Requirements A. Safety Related Issues: 1. All doors must be equipped with safety door sensors to prevent a door opening in someone's face. 2. Smoking and consumption of Alcohol on VA property: No smoking in any building on station. Provide contractors with a copy of Medical Center Policy 138-060. Mechanical rooms and contractor occupied areas are no exception. Also, contractors are NOT allowed to bring alcohol on to government property. Those who violate this policy can face up to a $300 fine. 3. Use of Existing VA Canteen: Contractors may use VA canteen for purchasing food so long as they have appropriate ID badge on and their clothes and footwear are free of excess dirt and debris. 4. Above Ceiling Work Permits: Contractor shall request and follow all provisions of approved permit(s) while working in the Medical Center. Working outside of construction barriers without having approved permit with construction personnel is cause for immediate cessation of work by the COR/CO. 5. Lock Out/Tag Out Energy Control Program shall be observed by all contractor personnel. Contractor is to submit a copy of their policy for approval. Provide contractors with copy of Medical Center Lock Out/Tag Out Policy 138-031. 6. Professional Behavior: Please remind all staff and subcontractors that they are working in an active medical center environment, and professional behavior is expected at all times. Since work is sometimes performed directly adjacent to active offices or patient care areas, please be cognizant of excessive noise and disruptions to those nearby (radios too loud, use of foul/inappropriate language, etc.) Warranty Period The vendor will warranty in full labor and material for one year. Special Instructions: All work will be completed 90 days from the day the contract is signed. ****A site visit is required by the contractor prior to bidding requirement.**** The quote will include all labor, material, equipment, freight charges, and testing to produce the end results described but not limited to the scope of work. Power shut downs will be scheduled with the VA. Normal work hours are 7am to 3:30pm. If needed off hours can be coordinated with VA to meet schedules.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/DaVAMC552/DaVAMC552/VA25015R0024/listing.html)
 
Document(s)
Attachment
 
File Name: VA250-15-R-0024 VA250-15-R-0024_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1783106&FileName=VA250-15-R-0024-002.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1783106&FileName=VA250-15-R-0024-002.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Louis Stokes VA Medical Center;10701 East Boulevard;Cleveland, OH
Zip Code: 441061702
 
Record
SN03601347-W 20141221/141219234811-1aa5aeb88487033d6b855b0ffb7fd2b2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.