DOCUMENT
Y -- Design/Bid/Build Construction Cooling Tower Replacement at BLDG. 77H - Attachment
- Notice Date
- 12/16/2014
- Notice Type
- Attachment
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- N40085 NAVFAC Mid-Atlantic, PWD PA 4921 S. Broad Street Building 1 Philadelphia, PA
- Solicitation Number
- N4008515R7516
- Response Due
- 1/5/2015
- Archive Date
- 3/31/2015
- Point of Contact
- JESSICA NELSON 215-897-8877 JESSICA.NELSON@NAVY.MIL
- E-Mail Address
-
<!--
- Small Business Set-Aside
- Total Small Business
- Description
- THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. THERE WILL NOT BE A SOLICITATION, SPECIFICATIONS, OR DRAWINGS AVAILABLE AT THIS TIME. The Naval Facilities Engineering Command, Mid-Atlantic PWD PA is seeking eligible business firms capable of performing Design/Bid/Build Construction Services for the replacement of a 25,000 GPM field-erected cooling tower and associated systems. Description of proposed project: The work associated with the Cooling Tower Replacement project includes the following main tasks: 1.Installation of a field-erected 25,000 GPM fiberglass reinforced plastic (FRP) 3-cell cooling tower, including water distribution system, utilized for process cooling. 2.Installation of a new pile supported concrete foundation and cold water basin for the cooling tower. 3.Modifications to the existing 36 cooling water supply and return piping from the existing cooling tower to the new cooling tower, including the installation of new 36 tee s and valves. 4.Removal and replacement of six (6) 8,350 GPM vertical turbine pumps and removal and replacement of one (1) 3,800 GPM vertical turbine pump. 5.Removal and replacement of the existing pump VFDs and soft start controllers with six (6) new VFDs. 6.Installation of a new fire suppression system for the new cooling tower. 7.Installation of a steel pipe bridge to support the connection of the new fire suppression system to an existing pump house. 8.Installation of a new Plant Control System and Human Machine Interfaces for control of the new cooling tower, pumps and associated monitoring devices. 9.Demolition and removal of the existing 25,000 GPM three-cell wood cooling tower and concrete basin after the new cooling tower is commissioned and accepted. The sequence of work is critical to minimize any disruption of existing cooling tower support to active test facilities. 10.Site work includes removal and re-routing existing utilities, including a new electrical duct bank. The new duct bank will be used by the local utility provider to install new MV cables. Fencing, grading, etc. is also required. It is requested that interested firms submit to the Contracting Officer a brief capabilities statement package (no more than 10 pages in length, single spaced, 12 point font minimum) demonstrating ability to perform the requested services. The documentation shall address, as a minimum, the following: 1.Relevant Experience to include experience in performing efforts of similar value, size, and scope within the last five (5) years including contract number, indication of whether your firm acted as a prime or subcontractor, contract value, Government/Agency point of contact and current telephone number, and a brief description of how the contract relates to the technical requirements described herein. 2.This response should include a discussion of resources available such as corporate management, currently employed personnel to be assigned, teaming partners under this effort to include professional qualifications, specific experience of such personnel, and the ability to have personnel located at the locations specified. 3.Company Profile to include the following: a. Number of employees. b. Office location(s). c. Available bonding capacity per contract. d. Small business designation/status claimed. Electronic submission of the statement of capabilities package will not be accepted.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62472PH/N4008515R7516/listing.html)
- Document(s)
- Attachment
- File Name: N4008515R7516_Sources_Sought_12-9-14.pdf (https://www.neco.navy.mil/synopsis_file/N4008515R7516_Sources_Sought_12-9-14.pdf)
- Link: https://www.neco.navy.mil/synopsis_file/N4008515R7516_Sources_Sought_12-9-14.pdf
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: N4008515R7516_Sources_Sought_12-9-14.pdf (https://www.neco.navy.mil/synopsis_file/N4008515R7516_Sources_Sought_12-9-14.pdf)
- Place of Performance
- Address: PHILADELPHIA NAVY YARD, PHILADELPHIA, PA
- Zip Code: 19112
- Zip Code: 19112
- Record
- SN03597755-W 20141218/141216234942-ed7681bcf178d5f6c3ba6e64db6c6dc5 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |