FBO DAILY - FEDBIZOPPS ISSUE OF DECEMBER 13, 2014 FBO #4767
SOLICITATION NOTICE

66 -- 5600A CoulArray 8-CH Detector Instrument 120VAC and accessories

Notice Date
12/11/2014
 
Notice Type
Presolicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
US Army Medical Research Acquisition Activity, ATTN: MCMR-AAA, 820 Chandler Street, Frederick, MD 21702-5014
 
ZIP Code
21702-5014
 
Solicitation Number
W81XWH15T0075
 
Response Due
12/17/2014
 
Archive Date
2/9/2015
 
Point of Contact
kevin comegys, 301-619-1128
 
E-Mail Address
US Army Medical Research Acquisition Activity
(kevin.e.comegys.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
MINIMUM ESSENTIAL CHARACTERISTICS HPLC SYSTEM Must meet all Specifications Brand Name or Equal ISO-3100BM HPLC Pump: Biocompatible, isocratic pump with serial dual-pistion design Pump flow rate range of 0.05 - 2.5 mL/min Maximum pressure rating must be greater than 6.000 psi over the entire flow range Isokinetic, pre-compression technology (Smartflow ), which performs automatic, on-the-fly, compression compensation for any solvent or solvent mixture to provide pulsation-free flow. Automated rear piston seal wash system with seal leak and wash fluid detection Pre-assembled, zero dead volume, finger tight UHPLC fittings for plumbing connections Real-time bidirectional control via USB WPS-3000TBRS : Inline split loop (No Sample Loss) injection design Sample capacity must be able to support 15, 10 mL reagent vials in addition to 120, 2.0 mL or limited volume vials Injection Volume range of 0.01 - 100 pL Injection Volume Accuracy of 0.5% at 20 pL Injection Volume Precision of less than 0.3% RSD at 2 pL (typically less than 0.15% RSD), caffeine in water Minimum Sample Required of 1 pL out of 5 pL (250 pL conical vial) Sampler must have fully biocompatible flow path and handle up to 15,000 psi Sample thermostatting of 4-45 C with accuracy of 2 C Sampler must be able to perform serial dilutions, sample dilutions and online sample derivatization Real-time bidirectional control via USB CoulArrav Thermal Organizer: Temperature controlled enclosure for organizing and maintaining constant temperature (range:ambient +5 to 45 C) for coulometric array cells and columns. Ability to hold 4 full length analytical columns (i.e., 250 mm, length) CoulArray Multi-Channel Electrochemical Detector Efficient, multi-channel, coulometrically efficient electrodes provide electrochemical resolution of chromatographically unresolved compounds Peak confirmation and purity assessment by internal signal ratio analysis Computer software control of operating parameters, data collection, analysis and reporting in the familiar Windows environment with powerful quote mark wizards quote mark that provide guidance for common operating tasks The only electrochemical detection system that is fully compatible with gradient elution chromatography Up to 16 patented, flow-through, Coulometric electrodes produces complete electrochemical conversion of analytes for improved detection (2 each 4-channel cells included with p/n 70-4324) Up to 16 channels of data can be acquired, analyzed, manipulated and reported simultaneously Data and graphics can be transfer directly into presentations and publications Dynamic range of femtomoles (10.15) to micromoles (10-6) within the same sample Multi-electrode sensors use maintenance-free reference electrodes eliminating the need for filling solutions and frequent polishing Autoranging gain control over 6 orders of detector response (10pA to 100pA) with programmable autozero capability Operates with all electrochemical cell types: single, dual and multi-channel Supports gating array configuration, as well as oxidation, reduction and redox Accepts analog signals from other detectors for concurrent display and analysis (optional analog input adapter required) An optional, integrated Thermal CoulArray Organizer is recommended that provides EC cells, columns and fluidic components with a thermally controlled operating environment which also eliminates outside electrical interferences to maintain high sensitivity measurements. This product shall meet all applicable UL, CSA, CE and FCC regulations. Chromeleon 6.8 Express Software: Shall have the ability to operate under Microsoft Windows 7 platform Supports instrument functions Shall be real-time bi-directional control with USB and online audit trail. Allows for editing of a running schedule for sample insertion Shall have a real-time view of chromatogram and spectra during a run. Shall have built in Wizards for setting up sequences, control programs, and quer Dionex 5040 Amperometric Cell with Boron doped Diamond Electrode for CoulArray Includes: Model 5040 Amperometric Analytical Cell, Boron-Doped Diamond disO electrode, disc electrode contact assembly, 0.001 quote mark (0.25 pm) gaskets, CoulArray-to-2-singlechannel cell cable and operating instructions EC kit and Installation: Vendor shall setup and ensure instrument meets specifications by performing instrument and software IQ with appropriate kits. Vendor shall familiarize operators on instrument operation including setting up programs files, sequences, and quantitation files. Shall include Mobile Phase (70-3829) and (45-0206) Test Standard Computer: Desktop CPU with Windows 7 Professional 64-bit, 3.4 GHz Core i7 3770, 8.0 GB RAM, Radeon graphics 1 GB, 1 TB SATA 6Gb/s disk, 16x DVD+/-RW Monitor: 23-inch LCD widescreen Flat Panel Monitor Equipment items that are needed: 5042.0011 1ea ISO-3100BM Pump - UtilMate 3000 Biocompatible Isocratic Anaylitcal Pump 5841.0020 1ea WPS-3000TBRS - UtliMate 3000 Wellplate Sampler, Thermostatted 70-4340T 1ea CoulArray Thermal Organizer Module 70-4324 1ea 5600A CouArray 8-CH Det Inst 120VAC - Electrochemical Detector 5960.0144 1ea CM-CMX/S-1: Xpress Server (Included 1X TB1) 70-8055 1ea 5040 Cell with BDD Kit for CoulArray 70-9191 1ea Kit, Access, CoulArray, U3000, System 70-7655 1ea EC Installation Kit for Coulochem III & CoulArray detectors includes Mobile Phase (70-3829) and Test Standard (45-0206) 076137 1ea PC, Dell, 9010, Intel Core i7, Win7-64 071664 1ea Monitor, Dell, U2312HM, 1920X1080 6000.1001 1ea Power Cord USA-Version - 125V 3xAWG18, 2.0 m Solicitation W81XWH-15-T-0075 is available via ASFI or by request to kevin.e.comegys.civ@mail.mil
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/USAMRAA/DAMD17/W81XWH15T0075/listing.html)
 
Place of Performance
Address: US Army Medical Research Acquisition Activity ATTN: MCMR-AAA, 820 Chandler Street Frederick MD
Zip Code: 21702-5014
 
Record
SN03593481-W 20141213/141211234309-085ada55b44c94cd91bea88a9f7ac314 (fbodaily.com)
 