Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF DECEMBER 11, 2014 FBO #4765
DOCUMENT

J -- Remove DSC Controller-TOP - Attachment

Notice Date
12/9/2014
 
Notice Type
Attachment
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office (NCO) 15;3450 S 4th Street;Leavenworth KS 66048
 
ZIP Code
66048
 
Solicitation Number
VA25515Q0214
 
Response Due
12/15/2014
 
Archive Date
1/14/2015
 
Point of Contact
Susan D. Miller
 
E-Mail Address
6-1989<br
 
Small Business Set-Aside
N/A
 
Description
The Department of Veterans Affairs, Colmery-O'Neil VA Medical Center, 2200 Gage Blvd, Topeka, Kansas. Contractor is to remove Digital Signal Control (DSC) to maximize the performance of equipment by ensuring that such equipment performs regularly and efficiently in accordance with each manufacturers' prescribed specifications and standards, and to maintain operational safety and reliability. Requests the following services: A) The existing Digital Signal Control [DSC] controller and controls on Air Handling Unit (AHU) 1-AC-3 located in building #1 2nd floor shall be removed. The contractor will install new electronic pneumatics (EP's) to the existing chiller water valve, hot water valve, face and bypass actuator. The outside air dampers are broken and need repaired and installed with a new spring return electronic actuator, replacing the existing pneumatic actuator. The Air Handling Unit (AHU) will need to be kept in operation during these repairs. The new controllers will be Bac-Net, and must be controls manufactured by Johnson Control, so they interface with existing Metasys System. The new network will need to be extended down to the mechanical room and must hook to the existing Metasys System so that they can be viewed and controlled from the front end. The existing inlet vanes and the across the line starter will be removed, and the disconnect will remain. A new frequency drive must be installed to control the fan speed. The new drive must be an ABB brand frequency drive. The new ABB frequency drive will be hooked to the existing Metasys System, so it too can be viewed and controlled from the front end. B) The existing Digital Signal Control (DSC) controller and controls that serves the Chiller, Cooling Tower Fan, and Pumps located in the service room of building #3 shall be removed. The new controllers will be Bac-Net, and must be controls manufactured by Johnson Controls, so they interface with existing Metasys System. The installer must be certified in the installation and programming of the new controls and existing Metasys system. C) The existing controls on the Air Handling Unit (AHU) located in building #3 that serves the lobby area shall be removed. The existing controls will be retrofit with Metasys Extended Arch Bac-Net controls that will interface with existing Johnson Controls Metasys Extended Arch control system. The existing pneumatic controls and damper actuators will be replaced with Johnson Controls certified equipment that will interface with Johnson Controls Metasys system. The pneumatic actuator for the preheat valve will be left in place and controlled by the new controls. Will need a new sensor mounted in the lobby area to feed back to new controllers for space temp control. Sensor must interface with existing Metasys system. The new controls will be networked into the existing Bac-Net network already located in Bldg. #3. Controllers to be installed must be manufactured by Johnson Controls so they can interface with the existing Johnson Control System. The NAICS code is 238220 and the small business size standard is $15 Million. This solicitation is set-aside for Small Businesses. The government contemplates a firm fixed price contract from this procurement. This requirement shall be completed in accordance with the Statement of Work. Contract period will begin December 19, 2014 or date of award. The point of contact for this procurement is Sue Miller, Purchasing Agent, Department of Veterans Affairs Heartland Network 15 Contracting Office 3450 S 4th Street Trafficway Leavenworth, KS 66048.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LeVAMC/VAMCKS/VA25515Q0214/listing.html)
 
Document(s)
Attachment
 
File Name: VA255-15-Q-0214 VA255-15-Q-0214_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1762789&FileName=VA255-15-Q-0214-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1762789&FileName=VA255-15-Q-0214-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;Colmery-O'Neil VA Medical Center;2200 Gage Blvd;Topeka, KS
Zip Code: 66622-0001
 
Record
SN03591395-W 20141211/141209234828-d24c2e44e01b1886536a93d9ee237323 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.