DOCUMENT
65 -- VISN 11 VISN Wide Cardiology DINS PACS Mr. Marlon Powell - Attachment
- Notice Date
- 10/31/2014
- Notice Type
- Attachment
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- Department of Veterans Affairs;OA&L/National Acquisition Center;National Contracting Services (003A4C3);Bldg. 37 Room 108 1st Ave. 1 BLK N. of;Cermak Road Hines, IL 60141
- ZIP Code
- 60141
- Solicitation Number
- VA797N14Q0013
- Response Due
- 11/14/2014
- Archive Date
- 2/12/2015
- Point of Contact
- Mr. Marlon Powell
- Small Business Set-Aside
- N/A
- Description
- VISN 11 RFI-PWS Draft FBO POSTING All vendors are requested to review the entire attached Draft Performance Work Statement Request For Information (RFI), which opens on 10/31/2014 and closes 11/14/2014, 4:00pm CST 1.No confidentiality forms or cost or pricing information is required from vendors as part of the RFI response. No offers are requested from vendors at this time, and no proprietary information required. This RFI is for marketing research purposes. 2.The Government's intent is to obtain general information from the vendors concerning their product and the draft Performance Work Statement (PWS); and vendors may ask general questions addressed to the Government. Participating vendors are required to read the entire PWS. Vendors may make suggestions and comments. The Governments' will respond back to vendors in writing to vendors questions related to the PWS. These written answers to vendors' questions and comment will be the official communications between Government and vendors'. The Government will publish all answers to vendor questions after the RFI has closed. The RFQ will be issued immediately after the RFI has closed. Vendors' questions should address the areas and topics contained in the Draft PWS and Functional Requirements Worksheet and highlight other relevant key features of the vendor system. This procurement is for one base and 4 option years. The Government reserves the right to exercise any or all option years. The Contracting Officer will send all written vendors' questions to the Integrated Product Team (IPT) Chairperson for coordination purposes before issuance of final PWS/RFQ Solicitation. All offers must monitor Federal Business Opportunity for dates for proposal submittal. 3. The RFQ will open for 30 calendar days (TBD)/2014 closing date (TBD)/2014. All proposals will be due on or before (TBD)/2014. No offers will be accepted after due date (TBD)/2014 3:00pm CST. Please be advised that the VA is planning to have a technical evaluation of all vendors' technical proposals. Technical proposal submission and the appropriate language and other information will be included in the RFQ that is now being drafted. NOTE: Department of Veterans Affairs VISN 11 requires that all vendors be on the DIN PACS III contract Defense Logistics Agency Troop Support (DLA-TS) on, or before the closing date of the RFQ posting date (TBD)/2014 Closing date (TBD)/2014. All proposals are due to the Contracting Officer. Marlon Powell Contract Specialist as stated in the RFQ once issued. You may contact me via email marlon.powell@va.gov or by phone (708)786-4927. RFQ #VA797N-14-Q-0013 VETERANS INTEGRATED SERVICE NETWORK (VISN 11) Consolidated Picture Archive and Communications System (PACS) POC: MARLON POWELL PO BOX 76 HINES, IL 60141 marlon.powell@va.gov (708) 786-4927 Cardiology Information PACS System Date: April 11, 2014 PWS Version Number: 1.0 Table of Contents 1.0Background4 1.1General Project Description4 1.2Purpose of Project5 2.0List of Cardiology Equipment per Site6 3.0List of Users By Site7 4.0Definitions/Glossary of Terms7 5.0Tasks/ Requirements8 5.1General Requirements8 5.2Ease Of Use10 5.3Data Management/ Connectivity11 5.4Technical Requirements12 5.5Data Security15 5.6Customer Service/ Support/ Training16 5.7Maintenance (during warranty and extended warranty period)17 5.8Future Updates17 5.9Other Requirements17 6.0Deliverables/ Delivery Schedule17 6.1What Contractor Will Provide17 6.2Contractor's Responsibilities17 6.3Specialized Expertise and Services, Training, and Documentation17 6.4Schedule For Delivery (quantities, where, etc) - chart ???18 6.5Documentation Provided19 7.0ACCEPTANCE PROCEDURES19 7.1No Substantial Clinical Use19 7.2Final Acceptance/Rejection Procedures19 7.3Final Payment20 8.0Period Of Performance20 9.0VA PERSONNEL INFORMATION21 10.0OTHER21 ? BACKGROUND General Project Description The mission of the Department of Veterans Affairs (VA) is to provide excellent healthcare services to veterans of the United States. The National Acquisition Centers, National Contracting Division, Contracting Office (NAC) is seeking competitive proposals from prospective contractors to provide, install and implement a turnkey VISN 11 Cardiology Information PACS System solution. This will be a straight purchase acquisition. Picture Archiving and Communication Systems (PACS) have been acquired and implemented in various configurations within VHA. It is beneficial to establish a standardized VISN-wide PACS with a common interface standard in order to, at a minimum, facilitate the care of patients referred amongst facilities within VISN 11, to ensure interface compatibility with the Veterans Health Information and Technology Architecture (VistA) and to share technical equipment expertise within VISN 11 straight purchase systems. The adoption of PACS in VHA is now nearly universal. PACS speeds health care decisions by making images available anywhere in the medical facility as soon as the image is acquired. PACS were initially acquired as independent systems at each Department of Veterans Affairs (VA) medical center. The process of transferring a study from one independent VA medical center PACS to another is laborious. It requires an order for the study to be placed at the second medical center, which results in duplicate medical record entry. More recently PACS have been acquired as a single system for the entire VISN. In this configuration, images are automatically shared across the VISN eliminating the need for an order to be placed in multiple VistA systems. In order to ensure this multi-facility interoperability, an enhanced HL7 interface has been developed. This interface improves on the older interface by ensuring that truly unique case numbers and study instances are generated by VistA. Unique identification is necessary to ensure compliance with the Digital Imaging and Communication in Medicine (DICOM) standard and is necessary when VISN 11 decides to transmit all studies to a Vendor Neutral and/or national archive. Competition for this RFQ shall be restricted to Defense Logistics Agency (DLA) Digital Imaging Network Picture Archive and Communications Systems (DIN PACS) III contract holders who are awardees as of the due date for receipt of offers. DIN-PACS III awardees may submit a bid, however, the successful offeror must be on the approved HL7 list at the time of the offer due date. Please use the following link for additional information: https://www.va.gov/IMAGING/HL7.asp. The VA will reject any proposals that are not HL7 approved at the time of the offer due date. The VA will not return such proposals and will dispose of them. Vendors will be allowed to make site visits for information purposes only. The Government will not be under any obligations at the time of vendors' site visits. Site visit will only be for information, questions, answering, oral presentations, and demo sessions. Purpose of Project Replace disparate Cardiac Catheterization and Echocardiography image management systems with a single, comprehensive VISN 11 Cardiology Information PACS System that provides open access to image interpretation and comparison, image capturing workstations, acquisition, viewing, archiving, and structured reporting regardless of where exams are performed. This shall include the software application and licenses, relevant hardware, including but not limited to VISN 11 redundant central archive medical device server, local servers, and local workstations, interfaces to medical devices, interfaces to VA's CPRS/ VistA, and interfaces to other systems. The scope of this initiative includes seven Medical Centers within VISN 11. This project enables VISN 11 to consolidate cardiology studies and patient monitoring sources on a standard computerized format, facilitating multiple data type integration from a diverse range of cardiology modalities and systems. 1.1.1A migration plan with associated costs and timeline for comprehensive storage of existing digital archives (includes CDs) with verification of data - ability to read and migrate DICOM compatible CDs to a Vendor Neutral Archive without Vendor propriety tags. The total migration capacity of existing systems is approximately 20TB. 1.1.2The proposed system solution shall provide a single point-of-access to unify data across the cardiac care continuum including: 1.1.2.1.1Multiple Care Venues - Cardiac specialty hospitals and centers, catheterization and EP laboratories, cardiac ultrasound, ECG, stress and Holter, cardiovascular surgery, emergency departments, cardiologist offices, congestive heart failure and lipid clinics. 1.1.2.1.2Multiple Imaging Modalities - Cardiac ultrasounds, nuclear medicine, computed tomography, x-ray angiography, magnetic resonance, computed and digital radiography. 1.1.2.1.3Interface Capabilities - Hemodynamics, pacemaker and ICD systems, patient monitoring devices, infusion devices, laboratory reference labs, ECG units and stress machines. How Project Relates To Other Projects All proposals must be fully compatible with a separate vendor neutral archive. Where Is Work Being Performed This proposal calls for the acquisition, installation, training and maintenance and interfacing with several common echo machine manufacturers of all cardiology equipment as well as all Cardiac Catheterization equipment within VISN 11. LIST OF CARDIOLOGY EQUIPMENT PER SITE SiteEquipment TypeQuantityManufacturerDevice Name/Model VA Ann ArborUltrasound5Philips IE33 Ultrasound2PhilipsCX50 Ultrasound1SiemensAcuson Sequoia Cardiac Cath1SiemensArtis Zee Single Plane Cardiac Cath1SiemensAxiom Artis Bi Plane EP Lab1GEInnova 2100 IQ Single Plane GE MAC Labs1GEMAC LABS Echo Image Mgmt. Sys1ProSolvProSolv VA DetroitUltrasound 3Philips IE33 Cardiac Cath1SiemensAxiom Artis dFC Echo Image Mgmt. Sys1ProSolvProSolv GE MAC Labs1GEMac Labs VA SaginawUltrasound 2PhilipsIE33 Echo Image Mgmt. Sys1ProSolvProSolv VA Battle CreekUltrasound1 Philips IE33 Echo Image Mgmt. Sys1ProSolvProSolv VA IndianapolisUltrasound 4 PhilipsIE33 Cardiac Cath1 PhilipsAllura XPER FD20 EP lab1PhilipsAllura XPER FD10/10 GE MAC Labs1GEMac Labs Echo Image Mgmt. Sys1ProSolvProSolv VA DanvilleUltrasound1Philips IE33 Ultrasound1SiemensAcuson Sequoia Ultrasound1Philipsi33 Cardiac Cath1SiemensCath Cor Echo Image Mgmt. Sys1ProSolvProsolv VA Ft. WayneUltrasound 2Philips IE33 Echo Image Mgmt. Sys1ProSolvProSolv LIST OF USERS BY SITE: SitePhysiciansTechniciansConcurrently working Ann Arbor121110 Detroit355 Saginaw112 Battle Creek022 Indianapolis8114 Danville343 Ft Wayne325 DEFINITIONS/GLOSSARY OF TERMS "AE - Application Entity "AQL-Acceptable Quality Level "CCOW - Clinical Context Object Workgroup "CE - Cardiology Equipment "CLWS - Clinical Workstation "CPRS - Computerized Patient Record System. The GUI interface to the Department of Veterans Affairs' HER - Electronic Health Record "CO-Contracting Officer "COR - Contract Officer Representative "DICOM - Digital Imaging and Communications in Medicine. A standard for distributing and viewing any kind of medical image regardless of the origin. "DXWS - Diagnostic Workstation "ePHI - Electronic Protected Health Information "HIPPA - Health Insurance Portability and Accountability Act "HIS - Healthcare Information System "HL7 - Health Level Seven. An all-volunteer, not-for-profit organization involved in development of international healthcare standards. "HL7" is also used to refer to some of the specific standards created by the organization. HL7 and its members provide a framework (and related standards) for the exchange, integration, sharing and retrieval of electronic health information. The standards, which support clinical practice and the management, delivery, and evaluation of health services, are the most commonly used in the world. "IHE - Integrating the Healthcare Enterprise "MOU - Memorandum Of Understanding "MPPS - Mega Pixel per Second "PACS - Picture Archiving and Communication System, medical device system "PHI - Patient Health Information "PWS-Performance Work Statement "QA-Quality Assurance "QASP-Quality Assurance Surveillance Plan "RPM-Required Performance Metrics "SLA - Service Level Agreement "SOW-Statement of Work "TJC -the Joint Commission on the Accreditation of Healthcare Organizations "VA - Department of Veteran Affairs "VAMC - Veterans Affairs Medical Center "VISN - Veterans Integrated Service Network. The VA is divided in to 21 VISNs (or regional authorities). "VISN 11 VA Medical Centers in Ann Arbor (MI), Detroit (MI), Battle Creek (MI), Saginaw (MI), Ft. Wayne (IN), Marion (IN), Danville (IL), and Indianapolis (IN). "VistA - Veterans Information Systems and Technology Architecture "VistA Imaging - An FDA-approved Image Management system used in the Department of Veterans Affairs healthcare facilities nationwide. It is one of the most widely used image management systems in routine healthcare use, and is used to manage many different varieties of images associated with a patient's medical record. "VNA - Vendor Neutral Archive TASKS/ REQUIREMENTS General Requirements Diagnostic cardiac images shall be accessed by any clinical provider in VISN 11 when fully launched within VISN 11, facilitating patient care. 1.1.2.2Use of existing echocardiography image management systems will remain in use until replacement of existing echocardiography systems occurs, the contractor will implement DICOM communication between existing systems and central repository that will enable continued use of existing systems while also enabling data sharing with the central repository, with the goal to transition to a standardized platform/ solutions. 1.1.2.3Provide new echocardiography image management and structured reporting solutions for all VISN 11 sites. 1.1.2.4Replace cardiac catheterization image management system at all facilities. 1.1.2.5Integrate to CPRS to achieve an orders-driven workflow that ensures reliable sharing of patient and exam information between CPRS and the central cardiology system, access to images within CPRS via single sign-on and DICOM Modality Work list distribution. 1.1.2.6The vendor shall describe its Technical Approach in response to this Performance Work Statement (PWS) that will meet or exceed current standards (DICOM, HL7, IHE etc.) including an itemized schedule of all milestones and deliverables, for the purposes of managing the resulting installation, implementation, modalities interfaces, training, support and the deployment of the entire Cardiology Information System including current and migrated old studies. 1.1.2.7The vendor shall provide and implement an alternative strategy for database backup redundancy, automated failover and system recovery so that no single point of failure can cause a major breakdown to VISN 11 Cardiology Departments. The vendor shall document and meet a total system uptime of 99% monthly and individual components uptime of 95% monthly in accordance with DIN PACS III section 2.4 Uptime Calculation. Component and system downtimes will include scheduled and unscheduled outages. 1.1.2.8The vendor shall provide the Contracting Officer's Representative (COR) the ability to run activity reports that show the number of studies captured in any billing cycle, maintenance/service and error logs, both consolidated VISN wide and by site. The installation plan will be due to the COR within 15 calendar days of contract award. 1.1.2.9The vendor shall provide the required interfaces as specified in their submitted timelines and as further defined herein for a complete turnkey product and fully functional Cardiology Information System ready to operate. Turnkey Installation is defined as the procurement, site planning, site preparation, configuration, and complete modalities interface installation of Cardiology Information Systems at all VISN 11 facilities by a single prime vendor. 1.1.2.10Remove chaos and disparity of paper-based solutions and disparate systems. 1.1.2.11Unify operations and data within the cardiovascular department. 1.1.2.12Reduce transcription costs associated with dictation. 1.1.2.13Must have FDA clearance for Picture Archiving and communication system (PACS) for the healthcare environment. All medical device system components must comply with FDA regulations for its specific classification, Class I, MDDS (Class I), Class II or Class III. Ease Of Use Cardiac Catheterization Workflow archive and retrieval from multiple venues through a single User Portal. Clinical automation needs of the invasive and non-invasive departments including the Catheterization lab, EP lab, Echo, Stress, Nuclear Medicine, and ECG departments. Streamline diagnostic and interventional workflow. Echocardiogram Reporting System with an option for sites to continue using their own echocardiogram reporting systems. Ability to retrieve patient test results through one interface simply by entering patient ID number, expediting comprehensive clinical assessment. Scalable design - A highly scalable design is required to accommodate entry level needs on up to complex departmental systems involving numerous data types; system configurability should allow a more precise match to departmental workflow needs. Retrieval of ECG for display. Retrieval of Stress test. Retrieval of Pacemaker data. Management of EP lab data. Query/Retrieval of studies from PACS. Integrated or Integration with Advanced Visualization software tools (3D). Easy retrieval of echocardiography and cardiac catheterization images. Increase access to information from multiple locations simultaneously and securely. To establish a more streamlined process for the Catheterization Lab's archiving and retrieval system. Data Management/ Connectivity Migrate legacy images from all existing imaging repositories in order to build a single, common VISN 11 Cardiology Information PACS image library. A Data Migration Plan associated with costs and timeline for comprehensive storage of existing digital archives (includes CDs) with verification of data - ability to read and migrate DICOM compatible CDs to a Vendor neutral Archive without Vendor propriety tags. Nuclear Cardiology Data Retrieval. Create, electronically sign, and finalize reports, as well as interface with CPRS/VistA. Edit and export to AVI files. Seamless integration between VISN 11 Cardiology Information PACS System and CPRS/VistA with an unlimited number of site licenses. 1.1.3Provide an enterprise license for VISN 11, providing software support for the VISN 11 Cardiology Information PACS System server, local acquisition/caching servers, and all medical device workstations throughout the following facilities within VISN 11 - to VA Medical Centers in Ann Arbor (MI), Detroit (MI), Battle Creek (MI), Saginaw (MI), Ft. Wayne (IN), Marion (IN), Danville (IL), and Indianapolis (IN). The Cardiology Information System enterprise viewer shall come with cardiac ready-made templates, and customize templates to suit cardiology provider preferences. The Cardiology Information System shall be an open architecture Windows program providing compatibility for image direct capture with all name-brand echocardiograph ultrasounds and cardiac catheterization lab systems. The system's algorithms shall be built on a single language, facilitating multiple data type integration from a diverse range of cardiology and patient monitoring sources. Reading via a VPN connection through the hospital system. The system will operate with LAN connection speeds within the Cardiology Reading Centers and shall guarantee diagnostic quality images to be viewed in real time without any delay for any requested exam regardless of exam age, provided the image does not need to be drawn from the central archive. Technical Requirements Imaging Management Hardware Requirements: 1.1.3.1Each facility will require a vendor provided local caching server at their facility for storage of Cardiac Catheterization images and Echocardiogram images with an option for sites to continue using their own echocardiogram reporting systems. A minimum of five (5) years of studies shall be stored on-line at the local facility. All images will be stored on-line, all the time in the VISN server. 1.1.3.2Images will then be uploaded to the vendor provided VISN Central Archive server (VA site to be determined) which will house a cardiology acquisition, archiving, storage and retrieval server. 1.1.3.3The Central Server archive must have enough capacity to hold at a minimum of an estimate of 20 years' worth of VISN's echocardiography and cardiac catheterization images and Clinical automation needs of the invasive and non-invasive departments including the Catheterization lab, EP lab, Echo, Stress, Nuclear Medicine, and ECG departments as well as any associated programs including a test/training account. Dedicated Medical Workstation Requirements 1.1.3.4Shall be bidirectional and interface with CPRS/VistA Imaging: able to retrieve procedure consults from VistA (work list), and then send a report to complete the consult. 1.1.3.5Shall analyze images and generate a report that can be sent to CPRS/VistA. Minimum Server Requirements 1.1.3.6Vendor to provide appropriate server numbers at each location based upon their technical proposal. 1.1.3.7The server shall be a standard rack mount. 1.1.3.8All servers shall have a dedicated UPS. 1.1.3.9The server shall have Technology Adapted (FATA) drives and dual ported Solid State Drives (SSD). 1.1.3.10Shall provide support for Direct Attach connection to Windows, Unix and Linux servers, without the need for SAN switches, and have SAN support for integrated EVA iSCSI connectivity options with Windows and Linux, Apple Mac, OS X, Microsoft Windows, Sun Solaris, VMware. 1.1.3.11The server shall have management of up to 1024 disks (256 per HBA), ranging in size from 1GB to 32TB per disk, in 1GB increments, along with Dynamic Capacity Management support to expand (in 1GB increments) and shrink LUNs up to 2TB and disk data load leveling (non-disruptive background activity). 1.1.3.12It shall have distributed sparing of disk capacity, redundant FC-AL loops from each controller to dual disk ports, dual redundant controller operation for increased fault tolerance, and robust local and remote replication capabilities. 1.1.3.13The server shall also be High availability with hot plug drives, power supplies, fans, and industry failover software, Multiple Bus Failover Support using industry popular multiple path software, and Battery-Back-Up for controller cache memory. Asynchronous Disk Swap (hot swap), Clustered Server Support, Mirrored Write-Back Cache Support, and read-Ahead and Adaptive Read Caching Support are also required. 1.1.3.14The server shall have online XCS software upgrade capability and online drive firmware upgrade capability. 1.1.3.15Other requirements include Selective Storage Presentation and SAN-based Data Zoning (through switches), and monitor and control health, end-to-end SAN performance and monitoring, storage utilization and reporting for all key SAN infrastructure including servers, storage, HBAs, switches, and applications. 1.1.3.16Server OS shall be Microsoft 2008 R2 64Bit or higher. Software Requirements 1.1.3.17Shall collect DICOM echocardiography and cardiac catheterization image studies from any device manufacturer. 1.1.3.18Shall be compatible and integrate with current echocardiography and cardiac catheterization image systems already functioning at each VISN 11 site. 1.1.3.19Integration with VistA Modality Work list- Shall query patient information directly from the CPRS/VistA system without having to handle manually inputted patient demographics. Create, electronically sign, finalize reports, as well as interface with CPRS/VistA. 1.1.3.20Ability to function even when the network is down - images shall be captured when the network is down, and when network comes back online, the images can simply be forwarded to the local server and to the VISN 11 central archive server. 1.1.3.21Ability to support satellite clinics and all facilities - software shall support multi-clinic sites. If a patient is seen at the Saginaw or any other site, then his/her images will be available at all the other VA sites through central backup server. 1.1.3.22Provide DICOM Modality Work list to all DICOM compliant imaging devices. 1.1.3.23Software is DICOM and CPRS/VistA compliant. 1.1.3.24In order to seamlessly integrate with CPRS/VistA, acquisition imaging software shall support DICOM query/retrieve. 1.1.3.25Provide image interpretation software for all cardiac catheterization exams performed in VISN 11. 1.1.3.26Provide image interpretation and structured reporting software for all echocardiography exams performed in VISN 11 (phased transition). 1.1.3.27Provide the DICOM routing and communication protocols necessary to connect the existing VISN 11 echocardiography image management systems with the central repository (supports the phased transition to a single solution without interrupting patient care). 1.1.3.28Provide a single VISN 11 work list that enables authorized users to access all current and historical image data from anywhere regardless of where exam is performed. 1.1.3.29Provide HL7 communication to CPRS/VistA for orders and results. 1.1.3.30Provide URL integration with CPRS/VistA for single sign-on access to images in CPRS. 1.1.3.31Vendor must specify and provide VA authorized virus protection software compatible with proposed system. 1.1.3.32All software licenses shall be perpetual. There shall not be any extra licensing costs for the life of the system. Data Security Any and all saving to a local system is required to be encrypted and the entire system needs to be compliant with all VA IT and privacy regulations All medical device components, including but not limited to: workstations and servers must be in compliance with VA MDIA (Medical Device Infrastructure Architecture) as well as comply with all FDA regulations. 2.5.3 All operating system and software (Java, Dot Net framework etc.) updates "patches" along with Intrusion Protection/ Prevention, Antivirus definition files, antivirus agents shall be kept current at all times. Regular virus scans shall be executed. Designated Biomedical and/ or VA Office of Information Technology staff will confirm compliance for patching and updating and report any instances where patching did not occur appropriately. Any suspected malware, breech of data or other information assurance concern will be reported to CIO; ISO and Biomedical staff immediately along with remediation plan (ensure system architecture is isolated to prevent further harm if required). Customer Service/ Support/ Training The vendor shall provide on-site installation to implement as well as configure the cardiac PACS system. Training for the management and maintenance of the cardiac PACS software will also be provided on-site to Biomedical Engineering Staff/system administrators at each of the VISN 11 site. Due to the extent of this project it is anticipated that a minimum of 2 days of training at each site in addition to the central server sites will be required. All training, regardless of length must satisfy the requirements listed above. The vendor shall provide support materials for the training as described above. The vendor shall provide ongoing Cardiology Information System Training and support to existing and new staff. All trained personal shall be provided a complete copy of their training material. A post installation follow-up visit shall be included by the vendor in order to ensure that the operation of the Cardiology Information PACS System is optimized by all users (Cardiology, Biomedical Engineering/system administrators). Vendor shall provide technical support as well as e-mail support during clinic operation hours and off-hours for service if necessary. VPN access could be made available to the vendor with appropriate security measures. A minimum of 1 printed set and 1 digital set of user and service manuals (as per VAAR regulation AS7004 Service Data Manual (SEPT 2007) covering the system administration, network architecture, data flow diagram, operation, installation, interface/integration, configuration to each site medical equipment modalities/systems, existing networked medical devices and maintenance of all system components explaining the operational concept of the system as a whole shall be provided. Maintenance during warranty and extended warranty period shall be in accordance with DIN PACS III Appendix 6 Specifications Future Updates Vendor will provide software updates and patches to keep Cardiology Information PACS System current, at no additional cost to the government during warranty period. As new technology emerges that is compatible with DICOM, the selected system shall accommodate. 5.8.3Hardware Lifecycle Management: Vendor shall provide a hardware end of life replacement plan. Other Requirements DELIVERABLES/ DELIVERY SCHEDULE What Contractor shall Provide Materials Rollout Schedule Migration Of Legacy Data New Studies Operations and Maintenance Contractor's Responsibilities 1.1.4Provide onsite training, implementation services, project management and professional services necessary to complete the project successfully. Specialized Expertise and Services, Training, and Documentation 6.3.1 Vendor shall provide Biomedical Engineering technical training for two staff from each facility, including travel and lodging. 6.3.2Vendor shall provide Information Technology technical training for two staff from each facility, including travel and lodging. Schedule For Delivery (quantities, where, etc.) Deliverables and Quantities Where/ When Delivered Delivery Schedule in Calendar Days From Date Of Award Services 1.1.4.1Offeror's project manager is a single point of contact for the delivery of a turn-key Cardiology Information PACS System 1.1.4.2Project Implementation teams that will install, configure, train, and test hardware and software components of the Cardiology Information PACS System. 1.1.4.3A Project Implementation Plan for the complete assessment, planning, installation testing, training and final acceptance of a ready to use Cardiology Information PACS System. 1.1.4.4Customized Cardiology Service clinical reports for interpretation, diagnosis, display, manipulation, printing, training, teaching, research, presentations, QC, coding, etc. 1.1.4.5The VISN CARDIOLOGY ARCHIVE and the first site shall start (live on line) within 90 days from contract award. Each site thereafter will commence in no more than 60 days. 1.1.4.6VA Vista, CPRS, existing and future Cardiology modalities interfaces. 1.1.4.7User training. 1.1.4.8System Admin training. 1.1.4.9Full documentation. 1.1.5Hardware 1.1.5.1Server 1.1.5.2Redundant / failover Server 1.1.5.3Workstations 1.1.5.4Switches 1.1.5.5Uninterruptible Power Supply (UPS) 1.1.5.6Equipment storage before installation (if required): 1.1.5.6.1Each station shall provide storage for equipment delivered to the station before installation begins. The station will offer segregated storage for this equipment, but will not be accountable for the equipment other than receiving the equipment in its shipping boxes and moving the equipment into segregated storage. 1.1.5.6.2Movement of the equipment from the storage location, rigging and special handling costs, if required to move the equipment from the storage area to the installation site are the contractor's responsibility. 1.1.5.6.3The Contractor is responsible for un-crating un-boxing the equipment and all required materials. 1.1.5.6.4Delivery shall be within 60 days and installation will be completed within 120 days after Receipt of Order (ARO) and sooner if practicable because of the critical need within VISN 11. 1.1.5.6.5Delivery and validation of all remaining application functionality to include but not limited to: system management, study workflow, peer review, critical results communication. 1.1.5.6.6Delivery and validation of all remaining application functionality to include but not limited to: system management, study workflow, peer review, critical results communication. 1.1.5.6.7Vendors are required to identify their nominal standard delivery time for each item offered. The exact required delivery date shall be specified on each delivery order. 1.1.6Software 1.1.6.1VA IMAGE SOFTWARE 1.1.6.2HL7 Interface specs 1.1.6.33RD Party Software Applications 1.1.6.4Virus Protection software 1.1.6.5Monitoring software Documentation Provided ACCEPTANCE PROCEDURES shall be in accordance with DIN-PACS III Specifications. No Substantial Clinical Use No Substantial Clinical Use means that delivered equipment is not able to perform the basic intended clinical function in a safe manner for the purpose for which it was designed and that most or all system functionality is not present, preventing the equipment from being used properly clinically during the 30-day period. If the equipment does not meet the criteria for Substantial Clinical Use, as defined in Section IV of this clause, the system will not be accepted without formal testing under Section II, and final payment will not be issued until after the equipment satisfactorily completes formal testing. Final Acceptance/Rejection Procedures In the event the equipment is not placed in Substantial Clinical Use for thirty (30) days, or is so placed and inspected and significant deficiencies are found, within twenty one (21) calendar days after receipt of the notice of readiness for inspection, the Government shall: 1.1.6.6accept the equipment; or 1.1.6.7accept the equipment and request that identified defects be remedied under the contract's warranty provisions; or 1.1.6.8request the vendor propose an equitable offset in lieu of correcting defects or rejection; or 1.1.6.9reject and request removal of the equipment. This section VI of the Acceptance Procedures clause is not intended to affect the parties' rights and responsibilities provided in sections I through V and section VII of the Acceptance Procedures clause. When requested, the contractor shall propose offsets within five (5) calendar days. If agreement is not reached with the Government on such offsets within five (5) calendar days thereafter, additional discussion on offsets may continue at the mutual agreement of the contractor and Government, or, at the request of either party, the Government will cease any clinical use, reject and request removal of the equipment. In cases of an offset, where the equipment is accepted by the Government, the commencement of the warranty period will be established by the contracting officer. If the equipment is rejected, the Government reserves the right to a complete refund. If equipment is rejected and the contractor is requested to remove such equipment, the contractor shall completely de-install all equipment items and remove them within 10 calendar days from the Government premises at the contractor's expense. Final Payment Final payment is due within 30 calendar days after formal acceptance. In cases where the Government accepts an offset proposal, final payment (if any is owed) is due within 30 calendar days of the Government's formal acceptance of the proposal. PERIOD OF PERFORMANCE SHALL BE IN ACCORDANCE WITH DIN-PACS III APPENDIX 6 VA PERSONNEL INFORMATION NameTitleOrganizationE-mailPhone Marlon PowellContracting OfficerVISN 11 Network Contracting Activitymarlon.powell@va.gov (708)786-4927 Mike JohnsonProgram ManagerChief, Biomedical Engineering Service, VA Ann Arbor Healthcare SystemMichael.Johnson3@va.gov 734-845-5420 Jay HallProgram ManagerChief, Biomedical Engineer, Detroit VAMCJay.Hall@va.gov 313-576-1257 Ron ChapmanProgram ManagerChief, Biomedical Engineer, Battle Creek VAMCRonald.Chapman@va.gov269-966-5600 x36102 Brian PetrellaProgram ManagerChief, Biomedical Engineer, Saginaw VAMCBrian.Petrella@va.gov989-497-2500 x13877 Hammam (Joe) HasanProgram ManagerChief, Biomedical Engineer, NIHCS VAMCHammam.Hasan@va.gov765-674-3321 x73453 Sam GantiProgram ManagerChief, Biomedical Engineer, Danville VAMCSrinivas.Ganti@va.gov217-554-5995 Jennifer DeFrancescoProgram ManagerChief, Biomedical Engineer, Indianapolis VAMCJennifer.DeFrancesco@va.gov317-988-2450 OTHER Competition for this RFQ shall be restricted to Defense Logistics Agency (DLA) Digital Imaging Network Picture Archive and Communications Systems (DIN PACS) III contract holders who are awardees as of the due date for receipt of offers. DIN-PACS III awardees may submit a bid, however, the successful offeror must be on the approved HL7 list at the time of the offer due date. Please use the following link for additional information: https://www.va.gov/IMAGING/HL7.asp. The VA will reject any proposals that are not HL7 approved at the time of the offer due date. The VA will not return such proposals and will dispose of them. The VA will not return pictures, documents, graphs, or interrelated requested information. Please direct any questions to Mr. Marlon Powell Contracting Officer, at e-mail: marlon.powell@va.gov. Interested parties are encouraged to submit their information as soon as possible. The deadline is November 14, 2014. Interested parties must submit information electronically. All requests for clarification or information must be submitted via email to Mr. Marlon Powell @ marlon.powell@va.gov Contracting Officer Department of Veterans Affairs National Acquisition Center, National Contracts (003A4C3). Phone: (708)786-4927.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANAC/VANAC/VA797N14Q0013/listing.html)
- Document(s)
- Attachment
- File Name: VA797N-14-Q-0013 VA797N-14-Q-0013_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1709022&FileName=VA797N-14-Q-0013-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1709022&FileName=VA797N-14-Q-0013-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA797N-14-Q-0013 VA797N-14-Q-0013_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1709022&FileName=VA797N-14-Q-0013-000.docx)
- Place of Performance
- Address: Veteran Integrated Sevice Network 11 (VISN 11);HSS Planning and Analysis;VAMC Ann Arbor Healthcare Systems;2215 Fuller Road;Ann Arbor, MI 48105
- Zip Code: 48105
- Zip Code: 48105
- Record
- SN03563235-W 20141102/141031234024-44685db0666c044ec82550f74f388cda (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)