Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 23, 2014 FBO #4716
DOCUMENT

65 -- ANESTHESIOLOGY CELL SAVER - Attachment

Notice Date
10/21/2014
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;VISN/18PHX;777 E. Missouri, Suite 300;Phoenix AZ 85014
 
ZIP Code
85014
 
Solicitation Number
VA25815Q0035
 
Response Due
11/4/2014
 
Archive Date
12/4/2014
 
Point of Contact
William Corson
 
Small Business Set-Aside
N/A
 
Description
Statement of Work Cell Saver Phoenix Veterans Administration Health Care Services 650 E. Indian School Road Phoenix, AZ 85012 Brand Name or Equal. Meet or Exceed. FOB Destination 1.0 Background The purpose of this Statement of Work is to procure one (1) cell saver CS5+, five (5) cases fast pack bowls 225 ml, five (5) cases fast pack bowls 125ml, one (1) case RBC bags 1000ml, and one (1) 10 liter waste bags. This is a machine that collects, washes, and processes the patient's blood from complex vascular surgery procedures to enable the transfusion of the patient's own blood. In accordance with Appendix A, Handbook 6500.6 Checklist blocks 6, the C&A requirements do not apply to this requirement, and Security Accreditation Package is not required. Due to the non-technical nature of this requirement, in reference to no. 6 there is no information to be protected. The period of performance will be 30 days after receipt of award. 2.0 Tasks: 2.1 Cell Saver CS5+ and disposable components Requirements: The contractor shall provide the following: Cell Saver "Machine alone (pole down) "Height: 37 in (94 cm) "Width: 16 in (40.6 cm) "Depth: 14.5 in (36.8 cm) "Machine (pole extended) "Height: 74.5 in (189.2 cm) "Width: 16 in (40.6 cm) "Depth: 14.5 in (36.8 cm) "Weight of machine 71 lb (32.2 kg) "Weight of cart 35 lb (15.9 kg) "Electrical voltage 100/220 VAC ( ± 15%), "switchable Pump speed 0-1000 mL/min (adjustable) "Centrifuge speed 2050-5650 rpm (adjustable) "Fuse rating F 2.5 A / 250V "Operating frequency 47-63 Hz "Power cord length 16 ft ( 4.9 m) "Certifications UL Listed Cells Saver consumables "5 cases/ 4 each per case- fast pack bowls 225 mL "5 cases/ 4 each per case- fast pack bowls 125 mL "1 case/40 each per case- RBC bag 1000 mL "1 case/ 20 each per case- 10 Liter waste bags 3.0 Delivery and Shipping Information: The contractor shall provide the following for shipment and delivery of equipment: All items shall be shipped FOB Destination to the following location: PVAHCS Anesthesiology 650 E. Indian School Road Main Bldg., 3nd Floor Phoenix, AZ 85012-1892
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PhVAMC/HMC/VA25815Q0035/listing.html)
 
Document(s)
Attachment
 
File Name: VA258-15-Q-0035 VA258-15-Q-0035_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1689728&FileName=VA258-15-Q-0035-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1689728&FileName=VA258-15-Q-0035-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;650 E Indian School Rd;Phoenix, AZ
Zip Code: 85012
 
Record
SN03554965-W 20141023/141021234401-0f5d547fbd7c0f45d7adeb293d2674c3 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.