MODIFICATION
J -- APPLICATION OF RHINOARMOR DUAL COMPONENT SYSTEM
- Notice Date
- 10/7/2014
- Notice Type
- Modification/Amendment
- NAICS
- 332812
— Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
- Contracting Office
- ACC - Rock Island (ACC-RI)(JMTC-RIA), Rodman Avenue Bldg 210, 1 Rock Island Arsenal, Rock Island, IL 61299-5000
- ZIP Code
- 61299-5000
- Solicitation Number
- W9098S15TGB01
- Response Due
- 10/10/2014
- Archive Date
- 12/6/2014
- Point of Contact
- Gail Bindewald, 309-782-3656
- E-Mail Address
-
ACC - Rock Island (ACC-RI)(JMTC-RIA)
(gail.bindewald@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Additional Information as of 7 Oct 2014: Material that the coating will be applied to is either ShieldStrand S OR S2, Fiberglass-fabric-reinforced phenolic laminate for use in composite armor systems in accordance with MIL-DTL-64154B with Amendment 1, Dated 19 January 2012, Class C (ShieldStrand S) or Class A (S2), Code 1. The test panel sizes are one half inch thick by 24 inches by 24 inches with an estimated weight of 22 pounds each. This weight applies to either type of panel. Production panels will be made of either of these materials with the largest size being one half inch thick by 26 inches by 45 inches. Rock Island Arsenal-Joint Manufacturing and Technology Center (RIA-JMTC) is seeking interest in the application of RhinoArmor PPFR 1150 two component, flame retardant, elastometric 100% polyurea system. The combined application will be comprised of RhinoArmor PPFR 1150 ISO Part #60042 and RhinoArmor PPFR 1150 Resin Part #60044. In accordance with manufacturers requirements cited for RhinoArmor PPFR 1150 total thickness to range between 1.5mm and 2.0mm. Final surface coat will be applied over CARC painted composite panels. Application will be to test panels that are approximately quote mark thick x 24 quote mark x 24 quote mark. Request respondees advise: 1) what size panels can you accommodate (panels may range up to quote mark thick x 26 quote mark x45 quote mark ; 2) estimate timeframe for application of RhinoArmor after receipt of test panels; 3) estimated timeframe for application of RhinoArmor on larger pieces; 4) number of panels you can apply RhinoArmor daily; 5) do you accept credit card payment. In addition, provide company name, point of contact, CAGE code, short explanation of experience, and if you are active in SAM. Panels would be shipped to your facility at RIA-JMTC's cost. Contractor would be responsible for return shipment; FOB is Rock Island, IL. This would be in support of a DX rated program. Request interest responses no later than 10 Oct 2014, however, earlier is appreciated. Contact Gail Bindewald, gail.a.bindewald.civ@mail.mil, 309-782-3656.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/9aefc103c4d92c1e042009ed33a84e14)
- Place of Performance
- Address: ACC - Rock Island (ACC-RI)(JMTC-RIA) Rodman Avenue Bldg 210, 1 Rock Island Arsenal Rock Island IL
- Zip Code: 61299-5000
- Zip Code: 61299-5000
- Record
- SN03544509-W 20141009/141007234435-9aefc103c4d92c1e042009ed33a84e14 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |