N -- BONNEVILLE SECOND POWERHOUSE POTENTIAL TRANSFORMER UPGRADE
- Notice Date
- 10/2/2014
- Notice Type
- Award Notice
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- USACE District, Portland, Contracting Division (CECT-NWP), P.O. Box 2946, Portland, OR 97208-2946
- ZIP Code
- 97208-2946
- Solicitation Number
- W9127N-14-R-0030
- Response Due
- 9/5/2014
- Archive Date
- 11/1/2014
- Point of Contact
- Jeffrey Renner, 503.808.4630
- E-Mail Address
-
USACE District, Portland
(jeff.s.renner@usace.army.mil)
- Small Business Set-Aside
- N/A
- Award Number
- W9127N-14-C-0037
- Award Date
- 9/30/2014
- Awardee
- BURKE ELECTRIC, L.L.C. (027354265) <br> 13563 SE 27TH PL <br> BELLEVUE, WA 98005-4212
- Award Amount
- $1,402,791.00
- Line Number
- 0001-0010
- Description
- The purpose of this project is to improve main unit circuit breaker synchronization by moving the synchronizing signal from the 230kV side of the GSU transformers to the 13.8kV side of the GSU transformers at the Bonneville Second Powerhouse in Skamania County, Washington. The existing signal on the grid side of the main unit circuit breakers comes from bushing potential transformers on the 230kV side of the GSU transformers. In order to get the same signal to the 13.8kV breaker synchronizing equipment without the small error introduced by the transformation through the GSU transformers, new 13.8kV potential transformers are required on the 13.8kV side of the GSU transformers. This project covers all work required to furnish, install, commission, and place in service the new 13.8kV synchronizing potential transformers at the Bonneville Second Powerhouse. This includes but is not limited to furnishing and installing four new potential transformer cubicles rated 13.8kV, complete with potential transformers, new isolated-phase bus from the cubicles tapping into the existing runs of isolated-phase bus, control wiring from the new cubicles to the existing main unit generator control boards, rewiring inside the control boards, and verifying and updating the control board wiring diagrams. Work must be performed over limited outages in two consecutive years.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA57/W9127N-14-R-0030/listing.html)
- Record
- SN03541403-W 20141004/141002235301-f96babbd058d4ecf53be509e09fb2731 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |