Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 27, 2014 FBO #4690
DOCUMENT

A -- 501-14-4-0157-0431 - PLASTIC BOTTLE UN-SCRAMBLER & BOTTLE CARRIER/TRANSPORTER - Attachment

Notice Date
9/25/2014
 
Notice Type
Attachment
 
NAICS
333993 — Packaging Machinery Manufacturing
 
Contracting Office
Department of Veterans Affairs;Contracting Office (501/90C);New Mexico VA Health Care System;1501 San Pedro Drive SE;Albuquerque NM 87108
 
ZIP Code
87108
 
Solicitation Number
VA25814Q0977
 
Response Due
9/26/2014
 
Archive Date
11/25/2014
 
Point of Contact
Bryan S. Rogers
 
Small Business Set-Aside
N/A
 
Description
The purpose of this amendment 1 to solicitation VA258-14-Q-0977 for: "Fully Automatic Plastic Bottle Un-scrambler / Cleaner & Multi-Purpose Bottle Carrier/Transporter", to be in accordance with specifications as outlined in the Statement of Work, is to provide responses to questions posed in response to the solicitation as published to the Federal Business Opportunities website on 9/20/14, with a quotation due date of 9/24/14. Due date for quotations is extended until 3:00pm, 9/26/14. All other terms and conditions of solicitation and synopsis remain unchanged.' Questions posed and responses: Does the machine need to be CE marked? No Requested output speed of machine? 30-35 btl pm MicroLogix 1000 PLC is standard. Do you need an upgrade? No Do you plan to run slower at start-up? If so, at what rate? NA Do you plan to run faster in the future? If so, at what rate? NA Customer conveyor fpm? Variable Is it a vacuum conveyor or airveyor? Neither, standard fda approved conveyor 4.5 inches wide Please provide conveyor cross section What is the discharge conveyor length? Conveyor to be a 7'6" long stainless steel, conveyor bed utilizing four 1/2" with a D.C. variable speed drive Is the conveyor a constant speed? variable What is the discharge height? As tall as 625cc wm round bottle Is roll ramp discharge required? NA If roll ramp is required, should the neck discharge towards, or away from machine? NA Will the hopper ever need to be in a different position? Hopper is built into machine Are there any changes requested or special features required? No Is Right hand or Left hand discharge required? Please refer to solicitation What will be the temperature of the containers when they enter the NEM machine? NEM? ambient Will the containers be Labeled or unlabelled containers? NA Handle orientation or off set neck orientation, if applicable? (This may require secondary orientation.) NA What type of plastic are the containers: PETE, PP, HDPE, LDPE, PS. HDPE - LDPE What are the color of the containers? (i.e. white, translucent, clear) Variable What is the total number of containers to run on this machine? NA Do you have special GMP issues such as covers, zero access requirements? Ionized Air Total number of caps/lids/other components (if applicable). NA Environment: hot, humid, wet, dusty? cGMP PKG / ISO 15378 What Class: Sterile, Clean Room (if applicable)? NA Are there special electrical requirements- NEMA-12, NEMA-4, NEMA-4X, NEMA-7? NA Is a UL certified panel required? A UL certified power tie in required 220V three phase, 60 Hz, 30 amps is standard for NEM equipment. Do you require a different voltage? No Will you need a Wash down, Wipe down requirement? Standard cGMP Please supply MSDS specs, or cleaning specs. NA Is a cleaner/rinser required? No What standard is required? cGMP Do you have a long conveyor? NA Do you need a motion detector? See specs Do aluminum components require coating? See specs Number of shifts per day: ___NA_______ Number of work days per week: ___NA_________ Is there a preventative maintenance program in place? NA Will there be floor space installation issues? See foot print specs Point of Contact: Bryan S. Rogers 505-256-2807 Bryan.Rogers2@va.gov
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AlVAMC501/AlVAMC501/VA25814Q0977/listing.html)
 
Document(s)
Attachment
 
File Name: VA258-14-Q-0977 VA258-14-Q-0977_2.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1652698&FileName=VA258-14-Q-0977-002.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1652698&FileName=VA258-14-Q-0977-002.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: VA Cooperative Studies Program;Clinical Research Pharmacy Coordinating Center;2401 Centre Avenue, SE;Albuquerque, NM
Zip Code: 87106-4180
 
Record
SN03528793-W 20140927/140926000049-2f91cd0bec1878889b9faed70241ae07 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.