MODIFICATION
66 -- Purchase and Install of Two Steam Sterilizers
- Notice Date
- 9/15/2014
- Notice Type
- Modification/Amendment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Health and Human Services, National Institutes of Health, Office of Administration, 6011 Executive Blvd, 5th Floor, Rockville, Maryland, 20852-3804, United States
- ZIP Code
- 20852-3804
- Solicitation Number
- RFQ-NIH-NEI-3532648
- Archive Date
- 10/3/2014
- Point of Contact
- Van V. Holley, Phone: 301-594-9439, Brendan MIller, Phone: 3015940957
- E-Mail Address
-
holleyv@od.nih.gov, brendan.miller2@nih.gov
(holleyv@od.nih.gov, brendan.miller2@nih.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- The following questions were received and responded to as part of this RFQ. In spite of not opening a question period, the government felt it was important to provide the information requested. 1. Is this subject to new / unused equipment only Turnkey project. 2. The RFQ calls for: Installation will include removal and disposal of existing equipment, receiving, uncrating, rigging, set-up and level, assembly, utility connections. a. Will a site visit be available? No b. If not, please provide the following information i. What floor does the unit go to? B1 ii. Is someone available to receive the unit? The unit will need to be received by the contractor with coordination of the loading dock personnel iii. Measurements of hallway, doorways. Smallest hallway is 48 wide ” and smallest door is 41 ½ wide” iv. Measurement of elevator, weight limitations? 7 feet wide and 8 feet high. 8,000 lb load capacity. 4. Is there an existing unit to be un-installed? a. If so who is to dispose of unit Yes, and it will be the responsibility of the contractor. 5. What utilities will be available? a. Water pressure Facility water supplied at 30-50 psig at 15 gpm @ 70oF, ¾”NPT. b. Steam pressure Facility trapped steam supplied at 40-80 psig at 1,200 lbs/hr, 1½” - 2”NPT. c. Floor drain 10”floor sink with 3” drain or 6-inch open facility floor drain. d. Electric 120V / 1 phase / 60 Hz / 5 amps e. Required shut-offs provided by customer
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/NIH/OoA/RFQ-NIH-NEI-3532648/listing.html)
- Place of Performance
- Address: Bethesda, Maryland, United States
- Record
- SN03511021-W 20140917/140915235314-ba696f7278d07892d8baf9d9ea1c9fe7 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |