DOCUMENT
65 -- VA250-14-Q-0803 CONTINUOUS AUTOTRANSFUSION SYSTEM PLUS - Attachment
- Notice Date
- 9/11/2014
- Notice Type
- Attachment
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office (NCO) 10;6150 Oak Tree Blvd., Suite 300;Independence OH 44131
- ZIP Code
- 44131
- Solicitation Number
- VA25014Q0803
- Archive Date
- 11/10/2014
- Point of Contact
- Christopher A. Callihan
- E-Mail Address
-
lthcare
- Small Business Set-Aside
- N/A
- Description
- INTENT TO SOLE SOURCE FAR 13.106(B) This is a notice of intent of The Louis Stokes Cleveland Department of Veterans Affairs Medical Center, 10701 East Boulevard, Cleveland, Ohio 44106-1702 to negotiate sole source with Terumo Cardiovascular Group for Terumo's Fresenius C.A.T.S Plus autotransfusion device for the Surgical Service at the Louis Stokes Cleveland VA Medical Center., with: Product No.DESCRIPTION QUANTITY 9005081Terumo Fresenius Continuous Autotransfusion System Plus4 EA 9108441ATH Collection Reservoir Holder4 EA The Louis Stokes Cleveland VA Medical Center has a need for Continuous Autotransfusion Systems for the Surgical Service. The Continuous Autotransfusion system collects and processes a patient's own blood during surgery, thus helping the patient avoid transfusions with donor, or banked blood. The system offers many advantages of traditional "bowl" autotransfusion systems, including fast processing time, higher hematocrit levels, and volume independent operation. This purchase is necessary because our current equipment is outdated and needs to be replaced. The continuous flow allows the machine to process any amount of blood at a time (for example: if there is only 200 mL of blood, the system will process it). Non-continuous transfusion systems must have at least 500 mL of blood in order for the system to trigger and process. With the continuous flow, there will be less blood wasted or thrown out. This device also decreases the risk of infection. Features of the system include: i.The only system that continuously salvages red blood cells for retransfusion ii.Consistently high Hct iii.Volume independent; no partial bowls or leftover blood iv.Complete elimination of non-emulsified fat v.Fast processing time: produces up to 100 mL packed RBCs/min vi.Lowest cell trauma vii.Automatic plasma sequestration viii.Easy and safe set-up ix.One "washing chamber" for all applications x.Color screen with on-screen instructions xi.Vacuum pump Bora (sold separately) The Government believes that only one business can satisfy the agency requirements and intends to negotiate with only one source under the authority of FAR 13.106(b) - access to proprietary information. Other persons may identify their interest and capability to respond to this requirement by Tuesday 16 September, 2014 at 12:00 PM EST. Such capabilities information will be used solely for the purpose of determining whether or not to conduct this procurement on a competitive basis. All information shall be furnished at no cost or obligation to the Government. A determination by the Government not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government. No solicitation is available at this time. All inquiries must be submitted by email to Christopher Callihan at Christopher.callihan@va.gov
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BreVAMC/VAMCCO80220/VA25014Q0803/listing.html)
- Document(s)
- Attachment
- File Name: VA250-14-Q-0803 VA250-14-Q-0803.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1627112&FileName=VA250-14-Q-0803-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1627112&FileName=VA250-14-Q-0803-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA250-14-Q-0803 VA250-14-Q-0803.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1627112&FileName=VA250-14-Q-0803-000.docx)
- Record
- SN03507345-W 20140913/140912000334-723eaee505c823c685b8af9a4a196883 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |