Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 06, 2014 FBO #4669
SOLICITATION NOTICE

Z -- NBSD FACILITY ENERGY IMPROVEMENTS PHASE 1

Notice Date
9/4/2014
 
Notice Type
Presolicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
N62473 NAVFAC SOUTHWEST, PW CONTRACTS UTILITY Code RAQ11 1220 Pacific Highway San Diego, CA
 
ZIP Code
00000
 
Solicitation Number
N6247313G1409X0002
 
Response Due
9/19/2014
 
Archive Date
9/19/2014
 
Point of Contact
Monica Hernandez 619-532-4052 monica.hernandez1@navy.mil
 
E-Mail Address
trella<br
 
Small Business Set-Aside
N/A
 
Description
THIS IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. The Naval Facilities Engineering Command, Southwest (NAVFACSW) intends to award a contract to one source (San Diego Gas and Electric Company) under the authority of 10 U.S.C 2913, which allows the Navy to enter into agreements with gas or electric utility companies to design and implement cost-effective demand and conservation incentive programs (including energy management services, facilities alterations, and the installation and maintenance of energy savings devices and technologies by the utility companies) to address the requirement and circumstances of the installation. NOTE: THIS SOLICITATION WILL NOT BE MADE AVAILABLE ON THIS WEBSITE. This notice is provided for information purposes only therefore FAR 5.203 does not apply. This opportunity is available only to the utility contractor servicing Naval Base San Diego in San Diego, California under a Utilities Energy Service Contract (UESC) N62473-13-G-1409, Basic Ordering Agreement(BOA), for the installation, replacement, renovation, repair, operation and maintenance of energy conservation measures and consuming equipment. Services shall include, but not be limited to, upgrades to Facilities Managment Systems (FMS), installation of energy management systems and direct digital controls, implementation of energy conservation measures, and limited Operation and Maintenance (O and M) services for any energy savings devices and technologies installed under any Delivery Order awarded under this BOA at Various Navy facilities within the service terrritory of San Diego Gas and Electric. 1.Building 12: Replace 2x2 fluorescent fixtures in weight room with drop in LED fixtures. Install reflectors in squash court light fixtures. Replace 2x2 fluorescent fixtures in upstairs exercise room with drop in LED fixtures. Replace high pressure sodium gymnasium lights with T5 fixtures. 2.Building 14: Retrocomission HVAC system. Replace pneumatic economizer damper actuators with DDC dampers. Replace missing economizer dampers on AHU. Replace HHW pump and heat exchanger nearing end of life. Replace exhaust fans nearing end of life. Replace fan coil unit near end of life. Replace vacuum pump near end of life. Replace air compressor nearing end of life. Replace T8 fixtures with super T8s. De-lamp room 341 to IESNA office light levels. 3.Building 15: Remove existing inoperable control system. Provide new AWEMS control system. TAB and comission new control system. Replace 2x4 T8s with super T8s. Add occupancy sensors to classrooms and breakrooms. Replace 10 exterior wall packs with LED wall packs. 4.Building 26: Connect DDC controls for 2 separate chiller plants into 1 AWEMS network controller. Upgrade sequence of operations to allow for staging of chillers to accommodate cooling load in energy efficient manner. 5.Parking Lot and Street Lights: Replace existing HID parking and street lights with bi-level LED fixtures. 6.M and V: A fully detailed M and V plan for each building will be generated during the design phase of the project, and approved before construction begins. Several sets of data will be recorded before and after construction under different building and outside environmental conditions. An M and V report will be provided annually, one year after construction is complete, with guidance for data collection/calculations for follow-on M and V efforts. a.LIGHTING: Energy calculations, spot measurements, and metering will be utilized to verify savings. b.DDC / EMS/HVAC: Existing metering, EMS data points, energy calculations, spot measurements, and building occupancy schedules will be used for baselining efforts. Similar sets of data to be taken after construction utilizing new EMS data points and logging systems in addition to the information sources used for baselining.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/1582eb60081ccecc001755b0e4916af8)
 
Place of Performance
Address: Naval Base San Diego, San Diego, Ca
Zip Code: 92132
 
Record
SN03495296-W 20140906/140904235032-1582eb60081ccecc001755b0e4916af8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)