Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 03, 2014 FBO #4635
SOLICITATION NOTICE

B -- Full Scale Longwall Roof Support System - SOW

Notice Date
8/1/2014
 
Notice Type
Presolicitation
 
NAICS
541330 — Engineering Services
 
Contracting Office
Department of Health and Human Services, Centers for Disease Control and Prevention, Spokane Research Laboratory, 315 East Montgomery Avenenue, Spokane, Washington, 99207
 
ZIP Code
99207
 
Solicitation Number
2014-73017
 
Archive Date
8/30/2014
 
Point of Contact
Denise L Rains, Phone: 509-354-8111
 
E-Mail Address
dgr8@cdc.gov
(dgr8@cdc.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
Statement of Work The proposed contract action for supplies/services for which the Government intends to solicit, negotiate, and enter into a Firm Fixed Non-Commercial Purchase Order IAW FAR 13, Simplified Acquisition Procedures for the following procurement, Full Scale Longwall Roof Support System. This posting will only be open for 15 days, no other notices will be posted FAR 5.202-13. The Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety & Health (NIOSH), Office of Mine Safety & Health Research (OMSHR) has a requirement for a ‘Full Scale Longwall Roof Support System.' The Full Scale Longwall Dust Gallery (Figure 1) in Building 151 of the Office of Mine Safety and Health Research's Pittsburgh Research Laboratory simulates the conditions found on many underground longwall coal mining faces in the United States (Figure 2). This laboratory provides an environment for the evaluation and optimization of longwall dust control techniques. Modifications and control of various operating parameters, such as mining height, spray system design, air flow, water spray quantity and pressure, and cutting direction provides researchers with feedback that would be impossible to duplicate in an operating mine. Continuous, real-time monitoring of air velocity, water pressure and flow, and dust levels at multiple locations is possible from the nearby control room. In order to fully simulate conditions along the longwall face, NIOSH requires twenty-two (22) full scale mockup shields. All changes to the requirement that occur prior to the closing date will be posted to FedBizOpps (FBO). It is the responsibility of interested vendors to monitor FedBizOpps for amendments that may be issued to this solicitation. For changes made after the closing date, only those offerors that provide a quotation/ proposal will be provided any changes/amendments and considered for future discussions and/or award. To be eligible for award of a Government contract, contractors must be properly registered in the System for Award Management (SAM). The link to the website is https://www.sam.gov. Contractors must be properly registered in the Government's System for Award Management (SAM) in order to respond to this solicitation. Offerors may obtain information on SAM registration and annual confirmation requirements by calling 1-866-606-8220 <img style="overflow: hidden; cursor: hand; height: 16px; vertical-align: middle; white-space: nowrap; right: 0px; position: static !important; float: none; left: 0px; margin: 0px; display: inline; top: 0px; width: 16px; bottom: 0px;" title="Call: 1-866-606-8220" src="data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAABAAAAAQCAYAAAAf8/9hAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAAIGNIUk0AAHolAACAgwAA+f8AAIDpAAB1MAAA6mAAADqYAAAXb5JfxUYAAAKLSURBVHjadJPfS5NhFMe/21xvuhXRyJAZroiSrJnbRdT7vrAf5HBaK5RABmEEwQIvkpZ/QRcWXdSFw5soKaF0F7qZeLO13mGBDpQsf5CoxVKHOt0Pctp2uvEdrzG/V+c553w/54HnPDIiQiGpPMETABoB2AAYd9MRAMMAvGmX+RcAyAoBVJ7gZQDtABworH4AHWmX+bOMZdkjCoXiUzabvcAwzPSsob5p/VTNY9GcdpnxdmYZ9wJThSCtCr1e/4XjuNPd3d1KjUZzaGbI27ysqzGQoggAsLa1A7ehArrDxfDNr0oBlQB+wmKxbJFEL968SxoamsjkHaPU9l9piUo6A0RE1DG2QCWdASrpDAzJM5kMI8XecdjVxfEl+K9dxFgsgUvvR6HyBKHyBAEATyKLeGSsENuNcqk5kUjEGm7fzcYqr0ClVODl99+YXEvl6+c1amjVe+ahiGGYaUEQKnmeh91uL43rqheixjpdmzCL11er0PcjhrTLvMfUJsyKYUSeyWQ6enp6tgCgrKxsfbP8bB8AdE1G89cOReMAgOv+Cag8QXRNRkXAsDwcDr+am5tLCYKA3t7eo2dG+1vVK/MfpRPtA+MIReMYaKj+/xm9MiICx3EmpVL5wefzFavValis1u1vvHMkdfykCQC0kSGUTo+Ajmnx1dSC7IGD+UUCEYGIwLKsyWazrSeTSSIiMpnNf7Ttz5+ec96fr7/VnE0mk+QfHMzV3WjcKH/4rEr05QGFIA6HY4llWRLPRER+v3/HYrFMFQSIkNra2tVQKJSlfcSyLO0LECFWq3XF6XRGA4HAptTsdrsXeZ6fEHtl+31nAOA4rkUulz/I5XL63dQGgHEAN8Ph8AYA/BsAt4ube4GblQIAAAAASUVORK5CYII=" alt="" />. or via the Internet at https://www.sam.gov. Electronic procedure will be used for this solicitation. Interested persons may identify their interest and capabilities to respond to the requirement or submit a proposal once the official solicitation is issued. Contact Denise L. Rains @ Drains@cdc.gov.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/CDCP/Spokane/2014-73017/listing.html)
 
Place of Performance
Address: National Institute for Occupational Safety and Health (NIOSH), Office of Mine Safety and Health Research, 626 Cochrans Mill Road, Pittsburgh, Pennsylvania, 15236, United States
Zip Code: 15236
 
Record
SN03446899-W 20140803/140801235004-23f18ce5e0324de8bbf48427b2b6b8f0 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.