SOURCES SOUGHT
54 -- Downdraft Paint Booth - Sources Sought
- Notice Date
- 7/1/2014
- Notice Type
- Sources Sought
- NAICS
- 332311
— Prefabricated Metal Building and Component Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, AFTC/PZIO - Eglin, 308 West D. Ave, Bldg 260, Suite 130, Eglin, Florida, 32542-5418, United States
- ZIP Code
- 32542-5418
- Solicitation Number
- FA2823-14-Q-3000
- Archive Date
- 7/30/2014
- Point of Contact
- Shenita C Humphrey, Phone: 8508822789, Ronald J. Wilson, Phone: 8508823466
- E-Mail Address
-
shenita.humphrey.2@us.af.mil, ronald.wilson.22@us.af.mil
(shenita.humphrey.2@us.af.mil, ronald.wilson.22@us.af.mil)
- Small Business Set-Aside
- N/A
- Description
- Paint Booth Requirements- MS Word Format THIS IS A SOURCES SOUGHT NOTICE FOR INFORMATION ONLY. THIS IS NOT A REQUEST FOR PROPOSAL OR QUOTATION OR AN ANNOUNCEMENT OF A SOLICITATION. This is a sources sought request for information (RFI) for the purpose of conducting market research to provide data for planning purposes. This sources sought synopsis announcement does not constitute a formal solicitation and is not a request for proposal, request for quote, invitation for bid, nor does its issuance in any way restrict the Government as to its ultimate acquisition approach. The Government will not pay for any materials provided in response to this notice and submittals will not be returned to the sender. This notice does not obligate the government to award a contract, issue a solicitation, reimburse respondents for any proposal preparation and/or submittal costs, nor does its issuance in any way restrict the Government as to its ultimate acquisition approach. The Air Force Test Center, Installation Operational Contracting Division, Eglin AFB, Florida, is seeking potential sources for the furnishing of a pressurized solid back modified downdraft paint booth. The following are the minimum specifications/requirements: Specifications/ Requirements: Need: 1 Pressurized Solid Back Modified Downdraft Paint Booth with NESHAP certification. Working dimensions: 14' wide x 12' tall x 26' long Overall dimensions: 15' wide by 14'2" tall x 26'4" long Exhaust fan : 36" diameter, 7.5HP, BSTAB 3-phase, 1.25" static pressure, 208/230/460V tubeaxial fan operating at 16,800 SCFM Doors: Personnel 30" x 84" with observation window 14 ½" wide x 48" tall will provide egress Product bi-fold door 9'4" wide x 11'10" tall with 2 windows (1 ea door) 14 ½" wide x 48" tall Lighting : 12 ETL listed Class I Div II Groups A,B,C, and D, Class II Div II Groups F & G sealed & gasket inside access fluorescent fixture; bulbs included Exhaust filtration : three stage conforming to NESHAP standards Horizontal, indoor, (AMU ): will provide 16,800 SCFM of heated replacement air to the paint booth. Capable of 100 degrees F temperature rise form a 2,000,000 BTU burner. AMU will cure at 160 degrees F, or code limits. A variable frequency drive for controlling the exhaust fan and booth light switch will be included with the controls package for the AMU. Exhaust ductwork : quote based on estimated roof height 27 feet with estimated roof pitch 1/12 pitch. Actual ductwork requirements will be dictated by field conditions including but not limited to actual roof height, roof pitch, obstructions, and local code restrictions. Construction Features Panels: fabricated from 18-guage galvanized steel punched on 6" centers. Panels fastened with 5/16" bolts and sealed with the provided caulk following assembly. Columns and beams: fabricated from structural steel members, punched on 6" centers to match corresponding panels Illumination: 48" long, 32 watt, T-8 type fixtures. Fixtures are supplied with dual ballasts for either 120V or 277V. Ballasts carry a 5 year limited warranty. NESHAP EXHAUST FILTRATION: Intake air filters: Rated by UL as Class @ and EPA registered as environmentally safe. Self-supporting in an internal frame sized 20" x 20" x 1". One set of filters to be supplied Exhaust filters: Efficiency rated to meet or exceed ATI A-3000 filtration system. One set ATI A-3000 filtration system is provided with unit. A manometer is provided with the unit to monitor filter resistance. Exhaust Fan Unit : a tube axial fan designed and constructed for paint spray booths is provided for exhaust. Requires a Precision balanced, fabricated, aluminum non-sparking fan blade. Motor, drive, and bearings are isolated from the exhaust air stream. Air Replacement Unit(AMU): Unit will have 1 direct fired natural gas heater, designed, assembled, wired and factory tested, providing 16,800 SCFM of clean tempered air @ ½" ESP, 2.0 million BTU burner supplying up to 100 degree temperature rise. Controls and gas train to be FM designed and ETL listed Maximum cure cycle temperature is 160 degrees F or as code limits A volume control damper is provided to vary the air volume during the cure cycle The AMU's control panel will be equipped with Variable Frequency Drive for the exhaust fan motor. Mounting stands and the inlet screen and filters are provided for the AMU. Product Door : entry/exit bi-fold door are fabricated with tube steel frames hung on structural channel jambs. Doors are skinned with 18-gauge galvanized steel sheet, sealed to the frame with sealant, and screwed in place. Doors are provided with foam rubber weather stripping seal about the perimeter and a neoprene rubber sweep at the threshold. The mounting hardware provided included a FM approved panic type safety latch and four door pulls. Personnel Door: Provided as an 18-gauge galvanized steel unit, pre-hung in a heavy steel frame ready for mounting. Mounting hardware includes FM approved panic type safety latch and two door pulls. Code Compliance: Must meet NFPA, Standard Number 33, and OSHA CFR 29.1910.107 Warranty: Minimum 1 year free from defects of material and workmanship Additional items : Paint booth panels and doors are to be powder coated white, bid must include freight and delivery, and include a factory start-up/training after installation (up to 8 hours). Feedback, questions, and comments regarding the above technical capabilities are welcomed. Interested firms are invited to submit a Statement of Capability (SOC) showing the company's ability to fulfill the requirement described above. It is the responsibility of the potential offerors to monitor these sites for additional information pertaining to this requirement. This is not a solicitation nor will a solicitation package be issued as a result of this announcement, and no award shall be made as a result of this announcement. In the event that a solicitation is developed, it will be assigned a formal Request for Proposal (RFP) number / Request for Quotation (RFQ) and the announcement may be published on FEDBIZOPPS. Responses to this notice will assist the government in identifying potential sources and determining if a set-aside of the solicitation is appropriate. Firms responding to this announcement should include company name, cage code, point of contact, address, phone number, small business size, and indicate whether they are small business, 8(a) concern, veteran-owned small business, service-disabled veteran-owned small business, HUBZone small business, small disadvantaged business, or women-owned small business. For the purposes of being considered a small business, the following applies: NAICS- 332311, Size Standard- 500. The Government reserves the right to set-aside any subsequent acquisition based upon known sources and/or responses to this synopsis. Responses are requested within 14 days. Contractual questions should be directed to the Contract Specialist, Shenita Humphrey, (850) 882-2789, or e-mail shenita.humphrey.2@us.af.mil.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/53a5332febb1e3110fd03e7b95102ac9)
- Place of Performance
- Address: Bldg 3117, Eglin, Florida, 32542, United States
- Zip Code: 32542
- Zip Code: 32542
- Record
- SN03411717-W 20140703/140702002225-53a5332febb1e3110fd03e7b95102ac9 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |