DOCUMENT
66 -- Reverse Osmosis Machine-STL JC - Attachment
- Notice Date
- 6/27/2014
- Notice Type
- Attachment
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office (NCO) 15;3450 S 4th Street;Leavenworth KS 66048
- ZIP Code
- 66048
- Solicitation Number
- VA25514Q1331
- Response Due
- 7/2/2014
- Archive Date
- 9/30/2014
- Point of Contact
- Rickie.Fearing@va.gov
- E-Mail Address
-
RICKIE.FEARING@VA.GOV
(RICKIE.FEARING@VA.GOV)
- Small Business Set-Aside
- Total Small Business
- Description
- This solicitation uses a Brand Name or Equal Description of the product required. This permits prospective contractors to offer products other than those specifically referenced by brand name. All offers must work with existing equipment that has already been purchased and is currently in use at the station and also to meet standardization requirements throughout the hospital. These machines are needed in our acute hemodialysis area to dialyze patients. Their purpose is to change the potable water into reverse osmosis water that is safe to use to dialyze patients with. The Acutes have increased in number which has put a great strain on the equipment we currently operate. We don't have enough machines to use on a daily basis to care for this increase in census. Power Supply Main voltage - 10, 115 or 220-240 V +/- 10%, 50 or 60 Hz Power - 100V: max 1500W, 115V: max 1380W, 220-240V: max 1850W Dimensions: Depth - Max: 20.5 inches Width - Max: 8.1 inches Height: 22.2 inches Depth - Footprint: 15 inches Width - Footprint: 7.3 inches Weight: 72.75 lbs. Feed Water Supply Input - 0.8 gpm required Pressure - 20 to 45 psi Temperature - 41 to 86 degrees Fahrenheit Potable water shall be used. Softener followed by carbon/particle filter Product Water Output - Minimum 0.3 gpm at 50 degrees Fahrenheit and 22 psi Quality - Total dissolved salts > 96%, bacteria and pyrogens > 99% Drain Requirements Operation - 0.32 + 0.03 gpm peak Flow (Rinse) - 0.8 gpm Reverse Osmosis Membrane Material - Polyamide, thin film composite Configuration - Spiral wound pH-Tolerance - 2-11 Disinfection & Cleaning Heat Disinfection - User initiated or automatic start of heat disinfection Chemical Disinfection - Automatic dilution of disinfectant. Rinse memory forcing the rinse program to start after chemical disinfection.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LeVAMC/VAMCKS/VA25514Q1331/listing.html)
- Document(s)
- Attachment
- File Name: VA255-14-Q-1331 VA255-14-Q-1331-PRESOLICITATION NOTICE.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1459719&FileName=VA255-14-Q-1331-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1459719&FileName=VA255-14-Q-1331-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA255-14-Q-1331 VA255-14-Q-1331-PRESOLICITATION NOTICE.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1459719&FileName=VA255-14-Q-1331-000.docx)
- Record
- SN03409293-W 20140629/140627235206-b0ed753e171cb60d9ec2c92b33d9beee (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |