SOURCES SOUGHT
61 -- SynQor UPS-1500-S-1U - Sources Sought
- Notice Date
- 4/3/2014
- Notice Type
- Sources Sought
- NAICS
- 335999
— All Other Miscellaneous Electrical Equipment and Component Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Special Operations Command, 1 SOCONS- Hurlburt, 350 Tully Street, Hurlburt Field, Florida, 32544-5810, United States
- ZIP Code
- 32544-5810
- Solicitation Number
- F2FF084062AC02
- Archive Date
- 4/25/2014
- Point of Contact
- Joel Berish, Phone: 850-884-7521, Jillian Martinez, Phone: 850-884-2083
- E-Mail Address
-
joel.berish@us.af.mil, jillian.martinez@us.af.mil
(joel.berish@us.af.mil, jillian.martinez@us.af.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Sources Sought SOURCES SOUGHT Market Survey DATE: 3 April 2014 Contracting Officer APPROVAL: __________________________ Type Requested: P - Procurement (Circle Alpha) A - Notice of Award R - SOURCES SOUGHT M - Modification - Type Mod: (Circle Alpha) P - Procurement A - Award R - Sources Sought N - Special Notice Supply or Services Classification Code NAICS: 335999 / SIZE: 500 Employees Subject of Sources Sought: SynQor UPS-1500-S-1U, Uninterruptible Power Supply (UPS). IFB/RFP Number: Response Date or Bid Opening Date: 04/10/2014 MO/DY/YR Contact Points: (Contract Person(s), Title, Phone Number(s)) Joel Berish, Contract Administrator, 850-884-7521 Jillian Martinez, Contracting Officer, 850-884-2083 Contract Award Number: N/A Contract Award Dollar Amount: N/A Contract Line Item Number(s): N/A Contract Award Date: N/A Contractor: N/A   NOTICE: Sources Sought SOLICITATION #: F2FF084062AC02 POSTING DATE: 3 April 2014 RESPONSE DATE: NLT 10 April 2014 2:00 p.m. EST NAICS Code: 335999 All Other Miscellaneous Electrical Equipment and Component Manufacturing SB Size Standard: 500 This announcement constitutes a Sources Sought Synopsis (market survey). This is not a request for quote (RFQ) or a request for proposal (RFP). This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. The Government will not pay for any cost incurred in responding to this announcement. Any information submitted by respondents to this Sources Sought synopsis shall be voluntary. This Sources Sought Notice is for Market Research purposes only. The information submitted in response to the Sources Sought Notice will not be utilized to determine vendor standing in any future/potential Request for Quote/Request for Proposal, nor will it be utilized to determine if a vendor is qualified to submit a Request for Quote/Request for Proposal for any future/potential requirement. The notice and the information received shall not be used to determine how well respondents can perform a requirement, which can only be evaluated in response to a solicitation. Vendors will not receive formal notification or feedback on any information submitted in this Sources Sought request. All future/proposed submissions/solicitations requirements solicited on a Government Point of Entry will be evaluated independent of any information submitted in response to this Sources Sought Notice. No vendor will be provided information on solicitations issued on a Government Point of Entry based on this Sources Sought request. This Sources Sought Notice is relative to the NAICS code 335999. The Small Business size standard for this NAICS code is 500. Large and Small Businesses are invited to answer this market survey to determine market capabilities. Hurlburt Field, FL, is conducting market research to determine the existence of potential sources to provide SynQor UPS-1500-S-1U, Uninterruptible Power Supply (UPS). The potential requirement will consist of the contractor providing: 1. SynQor UPS-1500-S-1U, Uninterruptible Power Supply (UPS) Specifications required 1. AC to DC power supply (UPS) 2. Load: 115VAC @10AMPS typical at max output load. AC Power Factor =.97 at 400Hz. 3. Single phase 115VAC 400Hz @10 Amps max input, 28VDC @35Amps output Input can also be run across two phases (208VAC @5.5AMPS) 4. MIL-STD 810, MIL-STD 461 and MIL-STD 704 5. Run time: 2 minutes at full load (1000 Watts) NOTE: Please submit electronic response indicating capability to supply the aforementioned item(s) via line card or published description (no more than 3 pages) as well as POC (name, telephone # and email address) along with contractor's CAGE, DUNS, and the physical location of your facility to the individuals listed within this notice. All work shall be performed at the contractor's facility. This request may not directly lead to a Request for Quotation/Proposal. Deadline for submission is 2:00 p.m. EST, 10 April 2014. Required Information: Any interested party who can offer all of the above may submit a written reply of not more than 3 pages, addressing each of the above items and defining how their location is capable of ALL of the minimum requirements listed above. Response deadline: 2:00 p.m. EST, 10 April 2014 Where to send responses: Joel.berish@us.af.mil 850-884-7521 Jillian.martinez@us.af.mil 850-884-2083 Other information: When and if released, the solicitation will be posted to the Federal Business Opportunities web site (www.fbo.gov).
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFSOC/16CS/F2FF084062AC02/listing.html)
- Place of Performance
- Address: Hurlburt Field, Hurlburt Field, Florida, 32544, United States
- Zip Code: 32544
- Zip Code: 32544
- Record
- SN03328720-W 20140405/140404000352-ed2e183648f0eab5420d1a846590441e (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |