Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 03, 2014 FBO #4513
DOCUMENT

65 -- AUDIOLOGY BOOTH - Attachment

Notice Date
4/1/2014
 
Notice Type
Attachment
 
NAICS
423450 — Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
 
Contracting Office
Department of Veterans Affairs;VA Sierra Pacific Network (VISN 21);VA Northern California HealthCare System;5342 Dudley Blvd. Bldg 98 (NCO 21);McClellan CA 95652-1012
 
ZIP Code
95652-1012
 
Solicitation Number
VA26114Q0402
 
Response Due
4/7/2014
 
Archive Date
6/6/2014
 
Point of Contact
jonathan.ursino@va.gov
 
E-Mail Address
jonathan.ursino@va.gov
(jonathan.ursino@va.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
a.The purpose of this amendment is to extend the due date and time for quotations and to provide additional technical data. b.The due time and date for quotations is April 7, 2014 at 3:00pm pacific time. c. Additional technical data Double Wall Audiometric Test Chamber Salient Characteristics Purpose - This item will be utilized to conduct full comprehensive hearing evaluations in a clinical setting for all of our Audiology clinics. 1) Essential/significant physical, functional, or performance characteristics. a)Compatibility - Must be compatible with existing equipment and space. See attached drawing b)Dimensions - Approximate standard size is outside dimensions 9'8"x (w) 11'10"x(h). Inside dimensions 7'8"x (w) 9'10"x (h) 6'6". c)Weight- Approximate standard weight is 10,600 lbs. d)Industry Standard - Must have double door system with hinges on right as door opens to outside and opens to left on inside - window on the left side of door with standard audiometric instrumentation jack connection panel (12x1/4" stereo connectors, 2xUSB services & 2"cable pull through) below window. Window is 2-frame, double glazed with ¼ " thick laminated safety glass. Data and fire alarm strobe access. HVAC hook-up (2x8"diameter). Vibration isolated acoustical floor system in exam and control room. Electrical wiring to be per 2002 National Electric Code or better UL certified and labeled Outer roof: Chamber must have exhaust fans and silencer screen, intake air fan and assembly, electrical power plug strip if required; Junction box and place for roof HVAC. Inner roof/ceiling lighting sufficient for office/patient/chamber operation. Double Door System. Window on left side of doors with standard audiometric instrumentation jack connection panel (12 x 1/4" stereo female connectors, 2 x USB services & 2" cable pull through). Further information: See attached facility room layout drawing. Customer to provide 120V, 60HZ power to one (1) roof mounted quad receptacle box power cord(s). *Contractor is to supply clear drawing with detailed equipment/electrical list and locations with quotation response. Facility Room Layout Dwg
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANCHCS/VANCHCS/VA26114Q0402/listing.html)
 
Document(s)
Attachment
 
File Name: VA261-14-Q-0402 A00001 VA261-14-Q-0402 A00001.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1285687&FileName=VA261-14-Q-0402-A00001000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1285687&FileName=VA261-14-Q-0402-A00001000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Palo Alto Affairs Medical Center;3801 Miranda Ave;Palo Alto CA;Install at Sa Jose, CA CBOC
Zip Code: 94304
 
Record
SN03325215-W 20140403/140401234340-6e778bf183964749276895aad9a240e9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.