DOCUMENT
65 -- AUDIOLOGY BOOTH - Attachment
- Notice Date
- 4/1/2014
- Notice Type
- Attachment
- NAICS
- 423450
— Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
- Contracting Office
- Department of Veterans Affairs;VA Sierra Pacific Network (VISN 21);VA Northern California HealthCare System;5342 Dudley Blvd. Bldg 98 (NCO 21);McClellan CA 95652-1012
- ZIP Code
- 95652-1012
- Solicitation Number
- VA26114Q0402
- Response Due
- 4/7/2014
- Archive Date
- 6/6/2014
- Point of Contact
- jonathan.ursino@va.gov
- E-Mail Address
-
jonathan.ursino@va.gov
(jonathan.ursino@va.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- a.The purpose of this amendment is to extend the due date and time for quotations and to provide additional technical data. b.The due time and date for quotations is April 7, 2014 at 3:00pm pacific time. c. Additional technical data Double Wall Audiometric Test Chamber Salient Characteristics Purpose - This item will be utilized to conduct full comprehensive hearing evaluations in a clinical setting for all of our Audiology clinics. 1) Essential/significant physical, functional, or performance characteristics. a)Compatibility - Must be compatible with existing equipment and space. See attached drawing b)Dimensions - Approximate standard size is outside dimensions 9'8"x (w) 11'10"x(h). Inside dimensions 7'8"x (w) 9'10"x (h) 6'6". c)Weight- Approximate standard weight is 10,600 lbs. d)Industry Standard - Must have double door system with hinges on right as door opens to outside and opens to left on inside - window on the left side of door with standard audiometric instrumentation jack connection panel (12x1/4" stereo connectors, 2xUSB services & 2"cable pull through) below window. Window is 2-frame, double glazed with ¼ " thick laminated safety glass. Data and fire alarm strobe access. HVAC hook-up (2x8"diameter). Vibration isolated acoustical floor system in exam and control room. Electrical wiring to be per 2002 National Electric Code or better UL certified and labeled Outer roof: Chamber must have exhaust fans and silencer screen, intake air fan and assembly, electrical power plug strip if required; Junction box and place for roof HVAC. Inner roof/ceiling lighting sufficient for office/patient/chamber operation. Double Door System. Window on left side of doors with standard audiometric instrumentation jack connection panel (12 x 1/4" stereo female connectors, 2 x USB services & 2" cable pull through). Further information: See attached facility room layout drawing. Customer to provide 120V, 60HZ power to one (1) roof mounted quad receptacle box power cord(s). *Contractor is to supply clear drawing with detailed equipment/electrical list and locations with quotation response. Facility Room Layout Dwg
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANCHCS/VANCHCS/VA26114Q0402/listing.html)
- Document(s)
- Attachment
- File Name: VA261-14-Q-0402 A00001 VA261-14-Q-0402 A00001.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1285687&FileName=VA261-14-Q-0402-A00001000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1285687&FileName=VA261-14-Q-0402-A00001000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA261-14-Q-0402 A00001 VA261-14-Q-0402 A00001.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1285687&FileName=VA261-14-Q-0402-A00001000.docx)
- Place of Performance
- Address: Palo Alto Affairs Medical Center;3801 Miranda Ave;Palo Alto CA;Install at Sa Jose, CA CBOC
- Zip Code: 94304
- Zip Code: 94304
- Record
- SN03325215-W 20140403/140401234340-6e778bf183964749276895aad9a240e9 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |