SOLICITATION NOTICE

Z -- Electrical Distribution

Notice Date
3/31/2014
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Labor, Employment Training Administration, Grafton Job Corps Center, 100 Pine Street, North Grafton, Massachusetts, 01536
 
ZIP Code
01536
 
Solicitation Number
331143
 
Archive Date
4/12/2014
 
Point of Contact
David K Field, Phone: 508-887-7362
 
E-Mail Address
field.david@jobcorps.org
(field.david@jobcorps.org)
 
Small Business Set-Aside
Total Small Business
 
Description
THIS IS A SUBCONTRACTING OPPORTUNITY WITH GRAFTON JOB CORPS / ADAMS AND ASSOCIATES AND NOT WITH THE U.S. DEPARTMENT OF LABOR. Scope of Work The building electrical distribution system is deteriorated. The building distribution system consists of a 400A MCB main distribution panel, 225A MCB supplemental distribution panel, four 200A MLO secondary panels serving the basement level loads and two 225A MLO panels serving the first level loads. The basement level secondary panels are original for the building and replacement parts for these panels as well as for the distribution panel are no longer readily available. The panels have exceeded their useful life. The individual breakers trip characteristics have likely changed, thus no longer fully providing their originally designed levels of protection. Also, there is abandoned conduit and wiring in the basement level, especially in the main switchgear room housing the seven section mid voltage switchgear. Provide design and construction. Replace the existing building distribution system with a new distribution system. Subject to replacement are distribution panels in the electrical room and secondary panels on the floors. Provide the new distribution panel with provision for service entrance for future use. (in case the building will be served from the electrical utility). Relocate a new panel serving the maintenance equipment storage area (considered flammable storage due to fuel operated equipment) to the nearest location in the north corridor, providing NEC required clearance. Reconnect branch circuit wiring and re-utilize existing feeders to the extent permissible by code. Provide a new type-written panel board directory in accordance with NEC. Provide new feeders in the existing conduits. Feeder runs are approximately 55 feet in length. Inspect and replace deteriorated branch circuits if required. Provide EMT conduit for branch wiring, where wiring is exposed. Remove all abandoned wiring. Provide ground fault protection at the service entrance. Provide copy of design and construction documentation to ESC. A Pre-bid meeting will be held on April 15, 2014 at 9AM. Attendance is mandatory for bids to be accepted. Contract David Field field.david@jobcorps.org or fax 508-887-7483. Phone calls will not be accepted. Bid will be due 7 days after the meeting. For a copy of the complete SOW please email and a copy will be sent.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOL/ETA/Graftonjcc/331143/listing.html)
 
Place of Performance
Address: 100 Pine St., North Grafton, Massachusetts, 01536, United States
Zip Code: 01536
 
Record
SN03324575-W 20140402/140331234438-c0f3e0ef54a1fd98ca8e8b693ba42049 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.