SOURCES SOUGHT
Z -- Sources Sought to provide design-build services upgrading the section alert fire alarm system to pin point addressable fire alarm system, replacement of interior lighting systems in the medical facilities at Misawa AFB, Japan.
- Notice Date
- 3/24/2014
- Notice Type
- Sources Sought
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- USACE District, Little Rock, 700 West Capitol, Little Rock, AR 72201
- ZIP Code
- 72201
- Solicitation Number
- W9127S-14-R-6008
- Response Due
- 3/28/2014
- Archive Date
- 5/23/2014
- Point of Contact
- lea.a.walker, 5013401032
- E-Mail Address
-
USACE District, Little Rock
(lea.a.walker@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- THIS IS A SOURCES SOUGHT ANNOUNCEMENT; A MARKET SURVEY FOR INFORMATION ONLY, TO BE USED FOR PRELIMINARY PLANNING PURPOSES. THIS IS NOT A REQUEST FOR PROPOSALS AND NO CONTRACT WILL BE AWARDED FROM THIS SYNOPSIS. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS SYNOPSIS OR ANY FOLLOW-UP INFORMATION REQUESTS. The US Army Corps of Engineers, Little Rock District, has been tasked to solicit for and award an Engineering Infrastructure Repair Design-Build Construction Services contract in support of the United States Air Force Medical Service (AFMS) Healthcare Facilities Modernization Program at Misawa Air Force Base, Japan. The Government is seeking qualified, experienced sources capable of performing the work described below. The purpose of this synopsis is to gain knowledge of interest, capabilities and qualifications of various members of industry, to include the Small Business Community. The type of acquisition to be issued will depend upon the responses to this synopsis. Interested sources are requested to provide the capabilities statements (no more than 6 pages) addressing the areas requested below and email them to: lea.a.walker@usace.army.mil not later than Friday, March 28, 2014. BACKGROUND In accordance with FAR 36/DFARs 236, the estimated construction price range for this project is: Between $1,000,000 and $5,000,000 Should the acquisition be set-aside for the 8(a) program, 8(a) firms are reminded they need to have a bona fide office in the geographical area of consideration where the work is to be performed as determined by SBA. REQUIREMENT Under this contract, the contractor shall provide all necessary labor, material, supervision, and equipment for the renovation/replacement of the fire alarm systems and interior lighting systems. The scope of work for the resultant contract will primarily be associated with the renovation/replacement of the existing facility/infrastructure equipment. Show experience performing fire alarm systems and electrical renovations in a Military Medical facility in Japan. All equipment must comply with the Buy American Act, but must meet or exceed the equipment codes of Japan. Explain the procedure of obtaining your labor crew, which will consist of foreign labor only, and how you will retain the disciplines required to complete the projects on schedule, providing a quality product. Explain how you will ensure that each laborer has a legitimate background check/screening and how you will work with both domestic and foreign security officials to ensure that both entities work in correlation with each other to not allow extended delays. Develop an engineering solution to upgrade the current section alert fire alarm system to a pin point addressable fire alarm system. The upgraded system must meet all ADA, NFPA, and applicable codes as they apply to fire alarm systems in the medical facilities. Develop an engineering solution that will address the outdated and energy inefficient interior lighting systems and replace those interior lighting systems in the medical facilities. CAPABLE OFFERORS MUST: 1) Show experience performing heating, ventilation, and air conditioning and building automation systems in a military medical facility in Japan. Building automation systems in Japan must conform to the country's codes and standards and must meet the needs of the military medical treatment facility. All equipment must comply with the Buy American Act, and must meet or exceed the equipment codes of Japan. 2) Demonstrate that you understand Japanese electrical code requirements and how to obtain them. All equipment used for testing, adjusting and balancing must be approved by customs and be authorized to be used in Japan. 3) Demonstrate an understanding of compliance with Status of Forces Agreement with the Japanese government. Explain the procedure of obtaining your labor crew, which will consist of foreign labor only, and how you retain the disciplines required to complete the projects on schedule, providing a quality product. 4) You must ensure that each laborer has a legitimate background check/screening. Briefly describe how you will work with both military and foreign security officials to ensuring the project's timely completion. 5) Provide no more than 6 pages of support for demonstrating capability. The North American Industry Classification System (NAICS) Code is 236220 - Commercial and Institutional Building Construction. The Standard Industrial Classification (SIC) Code is 1542 - General Contractors-Nonresidential Buildings, Other than Industrial Buildings and Warehouses. The US Small Business Administration Size Standard is $33.5 Million.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA03/W9127S-14-R-6008/listing.html)
- Place of Performance
- Address: USACE District, Little Rock 700 West Capitol, Little Rock AR
- Zip Code: 72201
- Zip Code: 72201
- Record
- SN03318651-W 20140326/140324234806-17936f95a6f164b0bb333ccd77188a6d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |