DOCUMENT
J -- SERVICES: CALIBRATION/PM & repair of INTELLIGUIDE FELS-25A Surgical Laser VA248-14-AP-5104 - Attachment
- Notice Date
- 3/20/2014
- Notice Type
- Attachment
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 8 (NCO 8);8875 Hidden River Pkwy Suite 525;Tampa FL 33637
- ZIP Code
- 33637
- Solicitation Number
- VA24814Q0686
- Archive Date
- 4/19/2014
- Point of Contact
- Michael Pierson
- E-Mail Address
-
michael.pierson@va.gov
(johnny.jones3@va.gov)
- Small Business Set-Aside
- N/A
- Description
- The Department of Veterans Affairs, Network Contracting Office-8, in support of James A. Haley Veterans Hospital intends to negotiate a noncompetitive award under Request for Quotation (RFQ) number VA248-14-P-2860, with Omniguide Inc., a large business to provide Repair and Calibration/Preventative Maintenance of an Omniguide Intelliguide FELS-25A Laser for James A Haley, Veterans Hospital, located at 13000 Bruce B. Downs Blvd, Tampa, FL 33612. This procurement is a sole source award pursuant to authority of sections 502 and 503 of Public Law 109-461, the Veterans Benefits, Health Care, and Information Technology Act of 2006 (38 U.S.C. §8127 (b)) and FAR 6.302-1 Sole source award under Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements. This notice is NOT a request for competitive proposals. The Government intends to award a fixed price contract in accordance with all terms and conditions of the solicitation. The NAICS code assigned to this acquisition is 811219 and the size standard is $19M. Scope of Work: The contractor shall provide all resources (labor, materials/parts, tools, equipment, and transportation) necessary to accomplish the deliverables described in this Statement of Work (SOW), except as may otherwise be specified. The vendor shall repair/PM the Intelliguide FELS-25A Laser to manufacturer's specifications. These include the following: - Checking the gas system outputs at 0 psi, 10psi, 50 psi & 70psi. - Inspect Laser and replace air filter, gas hose, & output tube male disconnect O-rings - Clean laser housing - Clean and inspect power cord - Test EMO switch for proper operation - Verify power up without errors - Record total system lasing time - Record software version - Verify power outputs of laser & save new value for Laser Light Test Voltage. All work shall be performed on-site at the James A. Haley Veterans' Hospital, 13000 Bruce B. Downs Blvd., Tampa, Florida 33612 at discretion of OR staff and biomedical personnel. Unit shall be returned to full operation at the conclusion of the work.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/TaVAMC673/TaVAMC673/VA24814Q0686/listing.html)
- Document(s)
- Attachment
- File Name: VA248-14-Q-0686 VA248-14-Q-0686_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1263202&FileName=VA248-14-Q-0686-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1263202&FileName=VA248-14-Q-0686-000.docx
- File Name: VA248-14-Q-0686 P03-Signed Finalized J_A.pdf (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1263203&FileName=VA248-14-Q-0686-001.pdf)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1263203&FileName=VA248-14-Q-0686-001.pdf
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA248-14-Q-0686 VA248-14-Q-0686_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1263202&FileName=VA248-14-Q-0686-000.docx)
- Record
- SN03316485-W 20140322/140320235536-08a7b45cbd0545a5c922ac6f016e29b7 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |