SOURCES SOUGHT

58 -- Radiacs for Present and Future FMS Cases

Notice Date
3/12/2014
 
Notice Type
Sources Sought
 
Contracting Office
ACC-APG - Aberdeen Division B, HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE, ABERDEEN PROVING GROU, MD 21005-1846
 
ZIP Code
21005-1846
 
Solicitation Number
MARKET-SURVEY-5580-1
 
Response Due
4/14/2014
 
Archive Date
5/14/2014
 
Point of Contact
Tineka C. Davis, 443-861-5439
 
E-Mail Address
ACC-APG - Aberdeen Division B
(tineka.c.davis.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
FOR MORE INFORMATION PLEASE CONTACT: Mitch Jacquay 443-861-5671 mitchell.a.jacquay.civ@mail.mil, Tony Blais 443-861-5672 anthony.w.blais.civ@mail.mil This is a Market Survey for Radiac PDR-77, VDR-2 and UDR-14 or commercial versions of these Radiacs. FOR MORE INFORMATION PLEASE CONTACT Mitch Jacquay, EMAIL mitchell.a.jacquay.civ@mail.mil, Tony Blais EMAIL anthony.w.blais.civ@mail.mil This survey has been published to satisfy immediate and future Foreign Military customer requirements. **You must respond NO LATER than the Respond Date and Time Specifications for the PDR-77 are as follows: Features Alpha Probe measures surface alpha particle contamination from background to 999 K cpm, background to 999 K dpm/100 cm2, background to 180 Ci/cm2. Beta/Gamma Probe detects and displays beta article radiation from background to 5 R/hr. Beta/Gamma Probe detects gamma radiation from background to 999 R/hr. X-Ray Probe detects the presence of Plutonium under adverse weather conditions from background to 999 K cpm. Powered by 5 BA-3090 batteries (three in Ratemeter, two in X-Ray Probe). Operational Detects and measures alpha, beta, gamma and x-ray radiation. Used for weapon surveillance, nuclear accident, and incident response and assistance (NAIRA). Also used for routine monitoring for health and safety. Replaces the AN/PDR-56 and the AN/PDR-60. Environmental Meets temperature extremes - -40 C to +49 C (-40 F to 120.2 F). Meets operating altitude up to 4572 m (15 000 ft). Physical Radiacmeter Weight - 1.25 kg (2.75 lb). Size - 18.2 x 10.4 x 4.8 cm (7.2 x 4.1 x 1.9 in.). Beta/Gamma Probe Weight - 0.455 kg (1 lb). Size - 3.7 x 3.7 x 17 cm (1.5 x 1.5 x 6.8 in.). Alpha Probe Weight - 1.178 kg (2.6 lb). Size - 13.34 x 8.7 x 28 cm (5.25 x 3.4 x 11.0 in.). X-Ray Probe Weight - 2.945 kg (6.5 lb). Size - 38.74 x 17.78 x 17.78 cm (15.25 x 7.0 x 7.0 in.). Pancake Probe Weight - 0.4 kg (0.88 lb). Size - 22.9 x 4.45 cm (9 x 1.75 in.). Gamma Micro quote mark R quote mark Probe Probe Weight - 0.45 kg (1 lb). Size - 3.81 x 25.1 cm (1.5 x 9.88 in.). Any source that can provide the exact same PDR-77 Radiac as described above or a commercial version of the PDR-77, that possesses the same performance characteristics must show: Information/data/documentation proving that their proposed Radiac is able to meet the above mentioned environmental temperature/altitude requirements. If the cited environmental conditions are beyond the scope of a proposed commercial version describe the limitations of the proposed commercial version Radiac. Specifications for theVDR-2 are as follows: FEATURES PRE-SETTABLE AUDIBLE AND VISUAL: Dose and dose alarms. SETUP TIME: For all checks and alarms less than 1 min. ACCURACY: 15 %. CIRCUIT PROTECTION: AN/VDR-2 is nuclear and EMP hardened. EMI COMPATIBILITY: Will not be affected, or cause other equipment to be effected by its use. OPERABLE AND READABLE: By persons wearing Arctic and MOPP protective clothing. WEIGHT: 1.73 kg (3.8 lb). VOLUME: 909 cc (58 cubic in.). DIMENSIONS: 18.2 x 10.4 x 4.8 cm (7.2 x 4.1 x 1.9 in.). DETECTORS Two GM Tubes. GAMMA RADIATION: 0.001 Gy/hr to 999 cGy/hr (dose rate) and 0.001 Gy to 999 cGy (total dose). ENERGY RESPONSE: 20% 80 keV to 3 MeV. DOSE RATE: Minimum detectable level 0.1 Gy/hr. RESPONSE TIME: Within 10% of final reading in four seconds at 1.0 cGy/hr, returns to background within four seconds. DISPLAY An auto ranging LCD can be read at 3 ft, back lit for night use, updated every two seconds. Provides dose and dose rate readout in units of Gy, cGy, Gy, Gy/hr, cGy/hr and Gy/hr. Other readout units available on request Rads or Sieverts TOTAL (CUMULATIVE) DOSE READ OUT: Will not be erased when read, resettable to zero as desired. ALARMS Has selectable Visual and Audible indicators for day or night use. Alarm levels are settable over entire dynamic range. POWER Three 9 V batteries. Minimum battery life of 150 hr of continuous monitoring. Low battery LCD indication with 5 hr of battery life remaining, a Go/No Go feature provides battery status. RELIABILITY AND MAINTAINABILITY MEAN TIME BETWEEN FAILURE (MTBF): Greater than 2000 hr. MEAN TIME TO REPAIR (MTTR): 15 min. ENVIRONMENTAL PARAMETERS OPERATING TEMPERATURE: -51 C to +50 C (-59.8 F to 122 F). STORAGE/TRANSPORT TEMPERATURE: -60 C to +70 C (-76 F to 158 F). HUMIDITY: 0-100%. IMMERSION: 3 ft for at least 2 hr. SAND/DUST: Operates in winds to 1750 ft/min with exposure to fine dust and to 5700 ft/min to sand particles. FUNGUS: Built from inherently fungus resistant materials. VIBRATION AND SHOCK: Withstands vibration associated with transport and shocks of dropping in use. ALTITUDE: 12 192 m (40 000 ft). EXPLOSIVE ATMOSPHERES: Will not cause ignition of explosive gas mixtures Any source that can provide the exact same VDR-2 Radiac as described above or a commercial version of the VDR-2, that possesses the same operational characteristics must show: Information/data/documentation proving that their proposed Radiac is able to meet the above mentioned environmental temperature/altitude requirements. If the cited environmental conditions are beyond the scope of a proposed commercial version describe the limitations of the proposed commercial version Radiac. Specifications for the UDR-14 are as follows: Features PRE-Settable Audible & Visual: Dose and Dose Rate Alarms Setup Time: Less than one minute for all checks and alarms Accuracy: 15% Enhanced Battery Life: Sleep mode provides 1500hrs battery life Circuit Protection: UDR-14 nuclear & EMP hardened EMI Compatibility: Will not be affected or cause other equipment to be effected by its use Operable and Readable: by persons wearing Arctic & MOPP protective clothing Weight: 9.5 oz. (270 g) Volume: 10.5 in (172 cc) Dimensions: 100mm x 66mm x 28mm (3.9in x 2.6in x 1.1in) Detectors Pin Diode (neutrons), PMOS-FET (prompt gammas) & GM detector (residual gammas). Separate detectors for neutrons & gammas are combined to provide a single dose reading. Reads In Tissue: dose centigray ( Gy), (Rads or Sieverts) available. GAMMA Dose Rate: independent to 108 Gy/s. NEUTRON dose Rate: independent to 1018 neutrons/cm2/sec. GAMMA Energy Dependence: 20% 80keV to 3MeV Neutron Energy: Thermal to 14 MeV. Total (Cumulative) Dose Read Out: will not be erased when read, resettable to zero as desired Dose Rate: minimum detectable level 0.2 Gy/hr. Response Time: within 10% of final reading in four seconds, returns to background within four seconds. Display An auto ranging LCD that can be read at 3 ft. back lit for night use, updated every two seconds. Data downloadable via optical (IR) communications port. Provide dose & dose rate readout in unit of: Gy, Gy, Gy, & Gy/hr cGy/hr and Gy/hr. Alarms Selectable Visual & Audible indicators for day or night use. Alarm levels are settable over entire dynamic range. Power Four (4) AAA 1.5 Volt batteries Minimum battery life of 150 hrs. during continuous monitoring and 1500hrs. during inactive (sleep) mode. Low battery LCD indication with 5hrs of battery life remaining a quote mark Go/No Go quote mark feature provide battery status. RELIABILITY AND MAINABILITY MEAN TIME BETWEEN FAILURE (MTBF): Greater than 2000hr. MEAN TIME TO REPAIR (MTTR): 15 min. Environmental Parameters Operating Temperature: -50 C to +50 C (-59.8 F to 122 F) Storage/Transport Temperature: -60 C to +70 C (-76 F to 158 F) Humidity: 0-100% Immersion: 3ft for at least 2hrs Sand/Dust: operate in wind to 1750ft/min with exposure to fine dust & to 5700ft/min to sand particles Fungus: Built from inherently fungus resistant materials Vibration & Shock: withstands vibration associated with transport & shock of dropping in use. Altitude: 12192m (40,000ft) Explosive Atmospheres: will not cause ignition of explosive gas mixtures. Any source that can provide the exact same UDR-14 Pocket Radiac as described above or a commercial version of the UDR-14, that possesses the same operational characteristics must show: Information/data/documentation proving that their proposed Pocket Radiac is able to meet the above mentioned environmental temperature/altitude requirements. If the cited environmental conditions are beyond the scope of a proposed commercial version describe the limitations of the proposed commercial version Pocket Radiac. 1.A quality system to monitor all phases of manufacturing will be requested after contract award. 2.Identify whether your small or large business 3.As stated, this market survey is for Foreign Military Sales Customers, and there is no funding available for support of developmental efforts or for qualification testing 4.Important considerations for review would be for: a. Ability to store dosage rates/ exposure data b.Down loadable data capabilities. c.Ability to withstand operation in a tactical military environment d.Delivery of approximately one year from date of contract award Respond to My Attention by COB Eastern on 14 Apr 2014
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/1656f7a93a1c81d37fed0d0f9eecec92)
 
Place of Performance
Address: ACC-APG - Aberdeen Division B HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE ABERDEEN PROVING GROU MD
Zip Code: 21005-1846
 
Record
SN03308479-W 20140314/140312234624-1656f7a93a1c81d37fed0d0f9eecec92 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.