SOLICITATION NOTICE
J -- Sole Source Posting - 2 each 4810 Sounders Upgrade
- Notice Date
- 2/28/2014
- Notice Type
- Presolicitation
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- USACE District, Rock Island, P.O. Box 2004, Clock Tower Building, Attn: CEMVR-CT, Rock Island, IL 61204-2004
- ZIP Code
- 61204-2004
- Solicitation Number
- W912EK-14-T-0058
- Response Due
- 3/5/2014
- Archive Date
- 4/29/2014
- Point of Contact
- Rebecca Costello, 309-794-5589
- E-Mail Address
-
USACE District, Rock Island
(rebecca.m.costello@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- The US Army Corps of Engineers, Rock Island District, intends to procure this requirement on a sole source basis in accordance with the statutory of 10 U.S.C. 2304(c)(1) as implemented by FAR 6.302-1, Only One Responsible Source and No Other Supplies or Service Will Satisfy Agency Requirements. The US Army Corps of Engineers, Rock Island District, intends to enter into a firm, fixed-price contract with Ross Laboratories Inc., 3138 Fairview Ave E, Seattle, WA, 98102-3097. The NAICS code for this procurement is 811219 with a size standard not to exceed $19,000,000. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES and no solicitation will be issued; however, any small-business firm that believes it can meet the requirement may give written notification to the Contracting Officer. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the requirement listed. A determination by the government not to compete this proposed contract based on responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. Questions should be directed to Rebecca Costello; Rebecca.M.Costello@usace.army.mil, ph 309-794-5589. Specifications Provide upgrades to MVR's two Ross Laboratories 4810 Sounders. Work includes: Remove and replace CPU A to D card, Clean and tighten receiver board edge connectors, Check/replace components and switches as necessary, Provide ZDA and 1 PPS compatibility, Reset AGC and TVG controls, test system. New parts required include: CPU Card; D525 1.8Ghz processor Pentium III or similar 4GB Ram A/D Card; 1000k samples/second SATA Hard drive, 64GB minimum Master Gain control on front panel Front and rear 2.0 USB ports Rear Ethernet port Smart Sweep software upgrade Serial port for output Serial port for GPS input.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA25/W912EK-14-T-0058/listing.html)
- Place of Performance
- Address: USACE District, Rock Island P.O. Box 2004, Clock Tower Building, Attn: CEMVR-CT Rock Island IL
- Zip Code: 61204-2004
- Zip Code: 61204-2004
- Record
- SN03299324-W 20140302/140228234209-80061918c7d51ce156e03e527c99d831 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |