45 -- HVAC Repair in NAG Bldg. 207 (Server Room) Kirtland AFB, NM.

Notice Date
1/24/2014
 
Notice Type
Award Notice
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
USACE District, Albuquerque, CESPA-CT, 4101 Jefferson Plaza NE, Albuquerque, NM 87109-3435
 
ZIP Code
87109-3435
 
Solicitation Number
W912PP14P0006
 
Archive Date
2/23/2014
 
Point of Contact
Glenda Kohlieber, 575-556-9940
 
E-Mail Address
USACE District, Albuquerque
(glenda.d.kohlieber@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Award Number
W912PP14P0006
 
Award Date
1/9/2014
 
Awardee
ORTEGA PLUMBING AND HEATING INC (615720880) <br> 38 HACIENDA DEL VALLE <br> PERALTA, NM 87042-8506
 
Award Amount
$71,464.78
 
Line Number
0001
 
Description
This contract action was accomplished using other than competitive procedures because a statute exists that expressly authorizes or requires that the acquisition be made from a specific source or through another agency (FAR 6.302-5); specifically, Sole source awards under the 8(a) Program. Per FAR 6.302-5 a J&A is not required for this award. The contractor shall furnish all parts, material, labor, equipment and supervision necessary to complete the work for Building 20451 National Assessment Group (NAG) HVAC Work in Server Room 207. The work shall include the following requirements listed in the specific requirements. The contractor shall assure the attached checklist and DD Form 1354 are completed and submitted to USACE and Kirtland AFB Reap Property office to get it staffed to the BCE for signature, at the conclusion of the project. SPECIFIC REQUIREMENTS: Contractor shall provide and install two Daikin Sky air Cooling only systems for the Server Room.Equipment provided will be 2 sky air condensers (cooling only) 2 round flow fan coil cassettes.Condensers will be located on north wall with standard concrete housekeeping pads. Electrical service is 208/230 and will be ran from north wall on the exterior of building. Controls will be remote navigation controllers. Install a 1 touch manager system that will be used for the Server Room HVAC system. Provide a factory start up and Training for Facility personnel.Continue the existing west wall up to the deck above to have a sealed conditioned space. Provide a Nortec Humidifier with remote mounted blower pack.Controls for the Nortec will be a wall mounted humidistat with digital display. Testing and balancing of the space will be required.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA47/Awards/W912PP14P0006.html)
 
Record
SN03274147-W 20140126/140124234353-c854094c371ec5300de23d5fba4e61cc (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.